Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1706.00174 · Applied Physics Express

All-polarization-maintaining, single-port Er:fiber comb for high-stability comparison of optical lattice clocks

Noriaki Ohmae, Naoya Kuse, Martin E. Fermann, Hidetoshi Katori

Published May 26, 2017• 42 citations
arXivHTMLPDF

Abstract

All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135–285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of (1–2) × 10 −17 Hz −1/2 at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with 10 −17 instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.

DOI
10.7567/apex.10.062503

Related papers

Simultaneous spectral purity transfer at three optical clock transitions using an ultra-low noise Er:Fiber frequency comb

Michele Giunta, W. Hänsel, Marc Fischer +2 more

We have performed a multi-branch Er:fiber-based frequency comb comparison for simultaneously address the stability at different spectral regions. The optical beats are synchronously realized for three relevant wavelengths, corresponding to half the Sr, Yb and Hg lattice clock transition frequencies, showing an integrated phase noise below 55 mrad (1 Hz-1 MHz) and modified ADEV of ~6×10-18at 1 s, averaging below 1×10-18in <;20 s (Lambda-mode, 1 s gate time).

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•5 citations

Sub-Hz Spectral Purity Transfer at the 10–18 level based on optical frequency comb

P. Zou, Michele Giunta, W. Hänsel +3 more

We report on a Er:fiber-based optical frequency comb transferring the stability of ultra-stable lasers from 194THz to 429THz. Sub-Hz level transfer to a fiber-delivered 698.44nm output port for future Strontium QPN-limited lattice clocks is demonstrated.

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)•Jan 1, 2018•0 citations

A 30-km-long optical fiber link for frequency comparison between distant strontium optical lattice clocks

Tomoya Akatsuka, Hitomi Ono, Keitaro Hayashida +4 more

We demonstrate a 30-km-long optical fiber link for frequency comparison between two strontium optical lattice clocks being developed at Riken and the University of Tokyo. We use a transfer laser at 1397 nm which is twice the wavelength of the clock transition of strontium clocks. The link stability is estimated to be 1×1017for an averaging time τ = 1 s, which is in good agreement with the theoretical limit calculated from the fiber noise spectrum. We discuss a remote clock comparison with stability of 10 (τ/s) by synchronously operating the two distant clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation

Sub-mHz Spectral Purity Transfer for Next Generation Strontium Optical Atomic Clocks

Michele Giunta, W. Hänsel, M. Lezius +2 more

We report on a Er:fiber-based optical frequency comb transferring the stability of ultra-stable lasers from 194THz to 429THz. Sub-mHz level transfer to a fiber-delivered 698.44nm output port for future Strontium QPN-limited lattice clocks is demonstrated.

Conference on Lasers and Electro-Optics•Jan 1, 2018•1 citation

Remote Comparison of Two Sr Optical Lattice Clocks through a 58 km Fiber Link

Tang-Yin 堂银 Liao 廖, Hao 豪 Liu 刘, Fei Meng +9 more

Abstract Two 87Sr optical lattice clocks (OLCs) are being developed and operated at the National Institute of Metrology (NIM), located on different campuses that are 40 km apart. In order to compare the optical frequencies of these two Sr OLCs, a 58-km noise canceled fiber link is built to transfer both a 1542-nm transfer laser and a microwave reference from Changping campus to Hepingli campus. Two commercial optical frequency combs (OFCs) with adapted single-branch 698/1542 nm outputs coherently unite the two 698-nm clock lasers and the 1542-nm transfer laser. The fractional instability of the comparison yields 3.1 × 10−17 at 10000 s averaging time. The measured fractional frequency difference between these two Sr OLCs was evaluated to be 1.9(3.2) × 10−17, which is within their claimed uncertainties. This result demonstrates the consistency of their frequencies when they serve as optical frequency standards. Our remote comparison demonstrates the feasibility of optical clock comparison through a long-distance fiber link and contributes to the progress of redefinition of the SI second.

Chinese Physics Letters•Feb 17, 2025•4 citations

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16

Laser Spectroscopy•Apr 1, 2008•0 citations
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135–285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of (1–2) × 10 −17 Hz −1/2 at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with 10 −17 instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.
We demonstrate a 30-km-long optical fiber link for frequency comparison between two strontium optical lattice clocks being developed at Riken and the University of Tokyo. We use a transfer laser at 1397 nm which is twice the wavelength of the clock transition of strontium clocks. The link stability is estimated to be 1×1017for an averaging time τ = 1 s, which is in good agreement with the theoretical limit calculated from the fiber noise spectrum. We discuss a remote clock comparison with stability of 10 (τ/s) by synchronously operating the two distant clocks.
Abstract Two 87Sr optical lattice clocks (OLCs) are being developed and operated at the National Institute of Metrology (NIM), located on different campuses that are 40 km apart. In order to compare the optical frequencies of these two Sr OLCs, a 58-km noise canceled fiber link is built to transfer both a 1542-nm transfer laser and a microwave reference from Changping campus to Hepingli campus. Two commercial optical frequency combs (OFCs) with adapted single-branch 698/1542 nm outputs coherently unite the two 698-nm clock lasers and the 1542-nm transfer laser. The fractional instability of the comparison yields 3.1 × 10−17 at 10000 s averaging time. The measured fractional frequency difference between these two Sr OLCs was evaluated to be 1.9(3.2) × 10−17, which is within their claimed uncertainties. This result demonstrates the consistency of their frequencies when they serve as optical frequency standards. Our remote comparison demonstrates the feasibility of optical clock comparison through a long-distance fiber link and contributes to the progress of redefinition of the SI second.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16