Proposed near-future upgrades of the current advanced interferometric gravitational wave detectors include the usage of frequency dependent squeezed light to reduce the current sensitivity-limiting quantum noise. We quantify and describe the degradation effects that spatial mode-mismatches between optical resonators have on the squeezed field. These mode-mismatches can to first order be described by scattering of light into second-order Gaussian modes. As a demonstration of principle, we also show that squeezing the second-order Hermite-Gaussian modes ${\mathrm{HG}}_{02}$ and ${\mathrm{HG}}_{20}$, in addition to the fundamental mode, has the potential to increase the robustness to spatial mode-mismatches. This scheme, however, requires independently optimised squeeze angles for each squeezed spatial mode, which would be challenging to realise in practise.
Proposed near-future upgrades of the current advanced interferometric gravitational wave detectors include the usage of frequency dependent squeezed light to reduce the current sensitivity-limiting quantum noise. We quantify and describe the degradation effects that spatial mode-mismatches between optical resonators have on the squeezed field. These mode-mismatches can to first order be described by scattering of light into second-order Gaussian modes. As a demonstration of principle, we also show that squeezing the second-order Hermite-Gaussian modes HG02 and HG20, in addition to the fundamental mode, has the potential to increase the robustness to spatial mode-mismatches. This scheme, however, requires independently optimised squeeze angles for each squeezed spatial mode, which would be challenging to realise in practise.
To date, frequency-dependent squeezed light has been used to reduce quantum noise in interferometric gravitational-wave detectors by 6.1 dB (a factor of two). Future upgrades and detectors aim to both reduce quantum noise by 10 dB (a factor of three) and to increase the circulating power in the interferometer arm cavities. Achieving these goals will be extremely challenging due, in part, to the degradations to the squeezed state caused by mode mismatch between the internal interferometer optical cavities and between the auxiliary external cavities. It is therefore imperative to gain a detailed understanding of all sources of mismatch and to obtain experience in mitigating their effects in the current detectors in order to improve astrophysical sensitivity now and in the future. Two types of internal mismatch are identified which are due to the thermal aberrations generated when the test mass optics absorb a small fraction of the circulating arm power. It is found that the dynamics responsible for the degradations caused by the mismatch between the quadratic part of the wavefront of two modes has a characteristic low-pass frequency dependence while the dynamics of the mismatch due to all higher order thermal aberrations has a high-pass behavior. As a consequence, the two types of mismatch are predominantly responsible for different squeezing degradations---some of which are significant for the current detectors and some of which will only be important for future detectors with longer arms. The behavior of these two types of internal mismatch are described, and the implications for detector design, operation, and characterization are discussed.
Gravitational-wave detectors use state-of-the-art quantum technologies to reduce the noise induced by vacuum fluctuations, via injection of squeezed states of light. Future detectors, such as Einstein Telescope, may require the use of two filter cavities or a three-mirror coupled filter cavity to achieve a complex rotation of the squeezing ellipse, in order to reduce the quantum noise over the whole detector bandwidth. In this work, we compare the theoretical feasibility and performances of these two optical layouts and their resilience with respect to different degradation sources (optical losses, mismatching, locking precision), analytically and numerically. We extend previous analysis on squeezing degradation and find that the coupled cavity scheme provides similar or better performances than the two-cavity option, in terms of resilience with respect to imperfections and optical losses. We further highlight the role of mode-mismatch phases in limiting squeezing. Finally, we propose a possible two-step implementation scheme for Einstein Telescope using a single filter cavity that can be possibly upgraded into a coupled filter cavity.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
Current interferometric gravitational wave detectors were designed to be limited, in much of their sensitive \nband, by quantum noise in the form of shot noise (at high frequency) or quantum radiation pressure noise \n(at low frequency). In the current observation run (O3), a squeezed light source has been used to \nmanipulate quantum noise and surpass the limits imposed by the circulating laser power by injecting nonclassical states of the electromagnetic field, called squeezed vacuum states, in the interferometer's dark \nport. Recent O3 results show that this technique was able to reduce the shot noise contribution to the \nnoise spectral density by about one half. To surpass the so called standard quantum limit across the entire \nsensitivity band, an even more complex variation of this technique will be implemented, which requires the \nuse of a so called “filter cavity” to reflect the squeezed quantum field and rotate the squeezing angle as a \nfunction of frequency. \nThe performance of this techniques is however severely limited by light losses. One big contributor to \noptical losses is the mismatch between the squeezed vacuum beam, the beam circulating into the \ninterferometer and, in the near future, the filter cavity fundamental transverse spatial mode. \nTo be able to monitor and actively correct mode mismatch, an accurate, online sensing technique is \nneeded. A possible solution consists in the introduction of an Electro-Optic Lens (EOL) that can induce \nradio-frequency sidebands in the Laguerre-Gauss 10 (LG10) transverse mode of the beam. If the \nmodulation frequency is tuned in a way that one sideband is at the cavity LG10 frequency, then the \nresonance breaks the symmetry of the two sidebands and converts phase modulation into amplitude \nmodulation, making it possible to retrieve an error signal directly from the cavity reflected electric field \nwith the same single-element photodetector used for the Pound Drever Hall (PDH) locking technique. This \nerror signal carries information about the magnitude and nature of the mismatch, providing all is needed to \ninform a dedicated feedback loop with a suitable actuator to maintain the mismatch at or below the 1% \nlevel. \nThe goal of this thesis is to demonstrate the technique on a dedicated bench-top experiment employing an \nEOL prototype device. The EOL alignment and working point, as well as the cavity lock parameters were \noptimized in an already existing setup. Simulations and theoretical calculations of the cavity reflected field \nwere performed to evaluate the system non-idealities: both Electro-Optic Modulator (for PDH technique) \nand EOL modulations effects and interactions, as well as some system imperfections were considered. The \nsimulations confirm that this technique requires a stable cavity lock condition, and for this reason an \naccurate study and optimization of the feedback loop parameters was done. In conclusion, a \ncharacterization of the EOL error signal response to different mismatch conditions are presented.
The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.
Strongly squeezed states of light are a key technology in boosting the sensitivity of interferometric setups, such as in gravitational-wave detectors. However, the practical use of squeezed states is limited by optical loss, which reduces the observable squeeze factor. Here, we experimentally demonstrate that introducing squeezed states in additional, higher-order spatial modes can significantly improve the observed nonclassical sensitivity improvement when the loss is due to mode-matching deficiencies. Our results could be directly applied to gravitational-wave detectors, where this type of loss is a major contribution.