arXiv:1702.01210 · Science

A Fermi-degenerate three-dimensional optical lattice clock

Sara Campbell, Ross B. Hutson, G. Edward Marti, Akihisa Goban, Nelson Darkwah Oppong, Rees L. McNally, Lindsay Sonderhouse, John Martin Robinson, W. Zhang, Benjamin Bloom, J. Ye

Published Oct 5, 2017• 399 citations
arXivHTMLPDF

Abstract

Making a denser optical lattice clock Some of today's most advanced clocks are made up of large numbers of atoms lined up in a one-dimensional (1D) optical lattice. The numbers improve clock stability, but atomic interactions can limit accuracy. Campbell et al. loaded their fermionic strontium atoms into a 3D optical lattice. The low temperatures and strong interactions ensured that the atoms avoided one another, resulting in a neat pattern where each lattice site was occupied by exactly one atom. This ordering reduced the influence of interactions on the clock's accuracy, whereas the high density of atoms enabled by the 3D geometry improved the precision. Science , this issue p. 90

DOI
10.1126/science.aam5538

Related papers

Making a denser optical lattice clock

Jelena Stajic

Optical Clocks Some of today's most advanced clocks are made up of large numbers of atoms lined up in a one-dimensional (1D) optical lattice. The numbers improve clock stability, but atomic interactions can limit accuracy. Campbell et al. loaded their fermionic strontium atoms into a 3D optical lattice. The low temperatures and strong interactions ensured that the atoms avoided one another, resulting in a neat pattern where each lattice site was occupied by exactly one atom. This ordering reduced the influence of interactions on the clock's accuracy, whereas the high density of atoms enabled by the 3D geometry improved the precision. Science , this issue p. [90][1] [1]: /lookup/doi/10.1126/science.aam5538

Science•Oct 5, 2017•0 citations

Suppression of Collisional Shifts in a Strongly Interacting Lattice Clock

Matthew D. Swallows, Michael Bishof, Yige Lin +4 more

Optical lattice clocks with extremely stable frequency are possible when many atoms are interrogated simultaneously, but this precision may come at the cost of systematic inaccuracy resulting from atomic interactions. Density-dependent frequency shifts can occur even in a clock that uses fermionic atoms if they are subject to inhomogeneous optical excitation. However, sufficiently strong interactions can suppress collisional shifts in lattice sites containing more than one atom. We demonstrated the effectiveness of this approach with a strontium lattice clock by reducing both the collisional frequency shift and its uncertainty to the level of 10(-17). This result eliminates the compromise between precision and accuracy in a many-particle system; both will continue to improve as the number of particles increases.

arXiv:1007.0059•Science•Feb 4, 2011•182 citations

Optical lattice clocks and frequency comparison

Hidetoshi Katori, T. Takano, Masao Takamoto

We consider designs of optical lattice clocks in view of the quantum statistics, relevant atomic spins, and atom-lattice interactions. The first two issues lead to two optimal constructions for the clock: a one-dimensional (1D) optical lattice loaded with spin-polarized fermions and a 3D optical lattice loaded with bosons. By taking atomic multipolar interactions with the lattice fields into account, an "atomic motion insensitive" wavelength is proposed to provide a precise definition of the "magic wavelength." We then present a frequency comparison of these two optical lattice clocks: spin-polarized fermionic 87 Sr and bosonic 88 Sr prepared in 1D and 3D optical lattices, respectively. Synchronous interrogations of these two optical lattice clocks by the same probe laser allowed canceling out its frequency noise as a common mode noise to achieve a relative stability of 3 × 10 −17 for an averaging time of τ = 350 s. The scheme, therefore, provides us with a powerful means to investigate intrinsic uncertainty of the clocks regardless of the probe laser stability. We discuss prospects of the synchronous operation of the clocks on the measurement of the geoid height difference and on the search of constancy of fundamental constants.

Journal of Physics Conference Series•Jan 10, 2011•2 citations

Strontium optical lattice clock with high accuracy and stability

Jan W. Thomsen, Gretchen K. Campbell, Andrew D. Ludlow +6 more

Techniques of modern quantum optics allows for the preparation of atoms in well controlled quantum states ideal for precision measurements and tests of fundamental laws of physics. We report on our recent progress with a highly stable and accurate optical atomic clock based on ultracold fermionic87Sr atoms confined in a one dimensional optical lattice. Currently, we have carried out a detailed evaluation of our clock at the 10−16level and can report stability at 2 x 10−15level at one second. At typical operating parameters for the clock we observe evidence of a density dependent clock shift. Operating the clock at a particular excitation ratio of ground state and excited clock state we observe a shift consistent with zero.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•2 citations

OPTICAL LATTICE CLOCKS WITH SINGLE OCCUPANCY BOSONS AND SPIN-POLARIZED FERMIONS TOWARD 10-17 ACCURACY

Masao Takamoto, Tomoya Akatsuka, Hidekazu Hachisu +3 more

We describe two possible configurations for optical lattice clocks; a one-dimensional (1D) lattice loaded with spin-polarized fermions and a three-dimensional (3D) lattice loaded with bosons. We realized these lattice clocks with fermionic 87 Sr and bosonic 88 Sr atoms and performed an optical frequency comparison between the two. The future prospects of a cryogenic Sr lattice clock and a blue-detuned lattice clock are also discussed.

Laser Spectroscopy•Feb 1, 2010•0 citations

Optical lattice clocks with non-interacting bosons and fermions

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka +1 more

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes; one-dimensional lattice loaded with spin-polarized fermions and three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic87Sr and bosonic88Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address our ongoing experimental challenges for optical lattice clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2008•3 citations
Making a denser optical lattice clock Some of today's most advanced clocks are made up of large numbers of atoms lined up in a one-dimensional (1D) optical lattice. The numbers improve clock stability, but atomic interactions can limit accuracy. Campbell et al. loaded their fermionic strontium atoms into a 3D optical lattice. The low temperatures and strong interactions ensured that the atoms avoided one another, resulting in a neat pattern where each lattice site was occupied by exactly one atom. This ordering reduced the influence of interactions on the clock's accuracy, whereas the high density of atoms enabled by the 3D geometry improved the precision. Science , this issue p. 90
Optical Clocks Some of today's most advanced clocks are made up of large numbers of atoms lined up in a one-dimensional (1D) optical lattice. The numbers improve clock stability, but atomic interactions can limit accuracy. Campbell et al. loaded their fermionic strontium atoms into a 3D optical lattice. The low temperatures and strong interactions ensured that the atoms avoided one another, resulting in a neat pattern where each lattice site was occupied by exactly one atom. This ordering reduced the influence of interactions on the clock's accuracy, whereas the high density of atoms enabled by the 3D geometry improved the precision. Science , this issue p. [90][1] [1]: /lookup/doi/10.1126/science.aam5538
Optical lattice clocks with extremely stable frequency are possible when many atoms are interrogated simultaneously, but this precision may come at the cost of systematic inaccuracy resulting from atomic interactions. Density-dependent frequency shifts can occur even in a clock that uses fermionic atoms if they are subject to inhomogeneous optical excitation. However, sufficiently strong interactions can suppress collisional shifts in lattice sites containing more than one atom. We demonstrated the effectiveness of this approach with a strontium lattice clock by reducing both the collisional frequency shift and its uncertainty to the level of 10(-17). This result eliminates the compromise between precision and accuracy in a many-particle system; both will continue to improve as the number of particles increases.
We consider designs of optical lattice clocks in view of the quantum statistics, relevant atomic spins, and atom-lattice interactions. The first two issues lead to two optimal constructions for the clock: a one-dimensional (1D) optical lattice loaded with spin-polarized fermions and a 3D optical lattice loaded with bosons. By taking atomic multipolar interactions with the lattice fields into account, an "atomic motion insensitive" wavelength is proposed to provide a precise definition of the "magic wavelength." We then present a frequency comparison of these two optical lattice clocks: spin-polarized fermionic 87 Sr and bosonic 88 Sr prepared in 1D and 3D optical lattices, respectively. Synchronous interrogations of these two optical lattice clocks by the same probe laser allowed canceling out its frequency noise as a common mode noise to achieve a relative stability of 3 × 10 −17 for an averaging time of τ = 350 s. The scheme, therefore, provides us with a powerful means to investigate intrinsic uncertainty of the clocks regardless of the probe laser stability. We discuss prospects of the synchronous operation of the clocks on the measurement of the geoid height difference and on the search of constancy of fundamental constants.
Techniques of modern quantum optics allows for the preparation of atoms in well controlled quantum states ideal for precision measurements and tests of fundamental laws of physics. We report on our recent progress with a highly stable and accurate optical atomic clock based on ultracold fermionic87Sr atoms confined in a one dimensional optical lattice. Currently, we have carried out a detailed evaluation of our clock at the 10−16level and can report stability at 2 x 10−15level at one second. At typical operating parameters for the clock we observe evidence of a density dependent clock shift. Operating the clock at a particular excitation ratio of ground state and excited clock state we observe a shift consistent with zero.
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes; one-dimensional lattice loaded with spin-polarized fermions and three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic87Sr and bosonic88Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address our ongoing experimental challenges for optical lattice clocks.