Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1608.02854

Salecker-Wigner-Peres quantum clock applied to strong-field tunnel ionization

Nicolas Teeny, Christoph H. Keitel, Heiko Bauke

Published Aug 9, 2016• 2 citations
arXivHTMLPDF

Abstract

The Salecker-Wigner-Peres quantum-clock approach is applied in order to determine the tunneling time of an electron in strong-field tunnel ionization via a time-dependent electric field. Our results show that the ionization of the electron takes a nonvanishing period of time. This tunneling time is of the order of the Keldysh time but strictly larger than the Keldysh time. Comparing the quantum-clock tunneling time to the mean tunneling time as obtained by the virtual-detector approach, one finds that these two complementary methods give very similar results. Due to the asymmetric distribution of the tunneling time, there is a nonnegligible discrepancy between the mean tunneling time and the most probable tunneling time.

DOI
10.48550/arxiv.1608.02854

Related papers

Tunneling Time, Exit Time and Exit Momentum in Strong Field Tunnel Ionization

Nicolas Teeny

Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schr{\\"o}dinger equation in one and two dimensions and use \\textit{ab initio} quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.

•Jan 1, 2016•1 citation

Distribution of ionization and tunneling times in a model of strong field ionization

Jose Tadeu Lunardi, Luiz A. Manzoni

Abstract We consider a simple model for strong field ionization and use the Salecker-Wigner-Peres clock to obtain a distribution of (real) times associated with this phenomenon. By coupling the Salecker-Wigner-Peres clock to the particle in different regions, we are able to distinguish between the ionization (exit) time, the tunneling time and the time the particle spends in the well before entering the barrier (the well time). We show that the distribution of ionization/exit times, which are the times usually measured in attoclock experiments, may differ significantly from the distribution of tunneling times, suggesting that the ionization times cannot be generally interpreted as tunneling times.

Journal of Physics Conference Series•Nov 1, 2019•1 citation

A Probability Distribution for Quantum Tunneling Times

Jose Tadeu Lunardi, Luiz A. Manzoni

We propose a general expression for the probability distribution of real-valued tunneling times of a localized particle, as measured by the Salecker-Wigner-Peres quantum clock. This general expression is used to obtain the distribution of times for the scattering of a particle through a static rectangular barrier and for the tunneling decay of an initially bound state after the sudden deformation of the potential, the latter case being relevant to understand tunneling times in recent attosecond experiments involving strong field ionization.

arXiv:1807.01814•Advances in High Energy Physics•Aug 19, 2018•5 citations

Salecker-Wigner-Peres clock and double-barrier tunneling

Marcos Calçada, Jose Tadeu Lunardi, Luiz A. Manzoni

We reexamine the Salecker-Wigner-Peres clock formalism and show that it can be directly applied to the phenomenon of tunneling. Then we apply this formalism to the determination of the tunneling time of a nonrelativistic wave packet, sharply concentrated around a tunneling energy, incident on a symmetric double-barrier potential. In order to deepen the discussion about the generalized Hartman effect, we consider the case in which the clock runs only when the particle can be found inside the region between the barriers and show that, whenever the probability to find the particle in this region is non-negligible, the corresponding time (which in this case turns out to be a dwell time) increases with barrier spacing.

arXiv:0901.0508•Physical Review A•Jan 22, 2009•23 citations

Salecker-Wigner-Peres clock, Feynman paths, and a tunneling time that should not exist

D. Sokolovski

The Salecker-Wigner-Peres (SWP) clock is often used to determine the duration a quantum particle is supposed to spend in a specified region of space $\mathrm{\ensuremath{\Omega}}$. By construction, the result is a real positive number, and the method seems to avoid the difficulty of introducing complex time parameters, which arises in the Feynman paths approach. However, it tells little about the particle's motion. We investigate this matter further, and show that the SWP clock, like any other Larmor clock, correlates the rotation of its angular momentum with the durations $\ensuremath{\tau}$, which the Feynman paths spend in $\mathrm{\ensuremath{\Omega}}$, thereby destroying interference between different durations. An inaccurate weakly coupled clock leaves the interference almost intact, and the need to resolve the resulting ``which way?'' problem is one of the main difficulties at the center of the ``tunnelling time'' controversy. In the absence of a probability distribution for the values of $\ensuremath{\tau}$, the SWP results are expressed in terms of moduli of the ``complex times,'' given by the weighted sums of the corresponding probability amplitudes. It is shown that overinterpretation of these results, by treating the SWP times as physical time intervals, leads to paradoxes and should be avoided. We also analyze various settings of the SWP clock, different calibration procedures, and the relation between the SWP results and the quantum dwell time. The cases of stationary tunneling and tunnel ionization are considered in some detail. Although our detailed analysis addresses only one particular definition of the duration of a tunneling process, it also points towards the impossibility of uniting various time parameters, which may occur in quantum theory, within the concept of a single tunnelling time.

arXiv:1703.01966•Physical Review A•Aug 14, 2017•15 citations

Quantum tunnelling time at long wavelengths

Zheng Shu, Da-Wei Tian, Jing-Yu Zhang +3 more

Abstract Quantum tunnelling is a fundamental phenomenon in quantum physics, yet the question of how long it takes for a particle to tunnel through a barrier remains a topic of ongoing debate. Recent advances in attoclock experimental techniques in strong-field physics have renewed interest in this topic. While various definitions of tunneling time have been proposed, a consensus has yet to be reached. In this study, we adopt a definition of tunnelling time based on the ratio of the barrier width to the expected value of the velocity operator within the barrier. This approach reduces to the Büttiker-Landauer time ($\tau_{BL}$) in the case of an opaque barrier and offers a clear physical interpretation for very thin barriers, where $\tau_{BL}$ may not be well-defined. Additionally, by utilizing a virtual detector at the tunnel exit, we calculate the time delay between the peak of the electric field and the moment of ionization for long wavelengths ($\geq$6 $\mu$m). Our findings indicate that the time delay stabilizes around 190 as, remaining independent of the laser wavelength. Furthermore, through our quantum tunnelling time definition, this time delay can be interpreted as the time required for the electron to tunnel from a point within the barrier to the exit.

Chinese Physics B•Mar 12, 2026•0 citations
The Salecker-Wigner-Peres quantum-clock approach is applied in order to determine the tunneling time of an electron in strong-field tunnel ionization via a time-dependent electric field. Our results show that the ionization of the electron takes a nonvanishing period of time. This tunneling time is of the order of the Keldysh time but strictly larger than the Keldysh time. Comparing the quantum-clock tunneling time to the mean tunneling time as obtained by the virtual-detector approach, one finds that these two complementary methods give very similar results. Due to the asymmetric distribution of the tunneling time, there is a nonnegligible discrepancy between the mean tunneling time and the most probable tunneling time.
Tunnel ionization belongs to the fundamental processes of atomic physics. It is still an open question when does the electron tunnel ionize and how long is the duration of tunneling. In this work we solve the time-dependent Schr{\\"o}dinger equation in one and two dimensions and use \\textit{ab initio} quantum calculations in order to answer these questions. Additionally, we determine the exit momentum of the tunnel ionized electron from first principles. We find out results that are different from the assumptions of the commonly employed two-step model, which assumes that the electron ionizes at the instant of electric field maximum with a zero momentum. After determining the quantum final momentum distribution of tunnel ionized electrons we show that the two-step model fails to predict the correct final momentum. Accordingly we suggest how to correct the two-step model. Furthermore, we determine the instant at which tunnel ionization starts, which turns out to be different from the instant usually assumed. From determining the instant at which it is most probable for the electron to enter the tunneling barrier and the instant at which it exits we determine the most probable time spent under the barrier. Moreover, we apply a quantum clock approach in order to determine the duration of tunnel ionization. From the quantum clock we determine an average tunneling time which is different in magnitude and origin with respect to the most probable tunneling time. By defining a probability distribution of tunneling times using virtual detectors we relate both methods and explain the apparent discrepancy. The results found have in general an effect on the interpretation of experiments that measure the spectra of tunnel ionized electrons, and specifically on the calibration of the so called attoclock experiments, because models with imprecise assumptions are usually employed in order to interpret experimental results.
Abstract We consider a simple model for strong field ionization and use the Salecker-Wigner-Peres clock to obtain a distribution of (real) times associated with this phenomenon. By coupling the Salecker-Wigner-Peres clock to the particle in different regions, we are able to distinguish between the ionization (exit) time, the tunneling time and the time the particle spends in the well before entering the barrier (the well time). We show that the distribution of ionization/exit times, which are the times usually measured in attoclock experiments, may differ significantly from the distribution of tunneling times, suggesting that the ionization times cannot be generally interpreted as tunneling times.
We propose a general expression for the probability distribution of real-valued tunneling times of a localized particle, as measured by the Salecker-Wigner-Peres quantum clock. This general expression is used to obtain the distribution of times for the scattering of a particle through a static rectangular barrier and for the tunneling decay of an initially bound state after the sudden deformation of the potential, the latter case being relevant to understand tunneling times in recent attosecond experiments involving strong field ionization.
We reexamine the Salecker-Wigner-Peres clock formalism and show that it can be directly applied to the phenomenon of tunneling. Then we apply this formalism to the determination of the tunneling time of a nonrelativistic wave packet, sharply concentrated around a tunneling energy, incident on a symmetric double-barrier potential. In order to deepen the discussion about the generalized Hartman effect, we consider the case in which the clock runs only when the particle can be found inside the region between the barriers and show that, whenever the probability to find the particle in this region is non-negligible, the corresponding time (which in this case turns out to be a dwell time) increases with barrier spacing.
The Salecker-Wigner-Peres (SWP) clock is often used to determine the duration a quantum particle is supposed to spend in a specified region of space $\mathrm{\ensuremath{\Omega}}$. By construction, the result is a real positive number, and the method seems to avoid the difficulty of introducing complex time parameters, which arises in the Feynman paths approach. However, it tells little about the particle's motion. We investigate this matter further, and show that the SWP clock, like any other Larmor clock, correlates the rotation of its angular momentum with the durations $\ensuremath{\tau}$, which the Feynman paths spend in $\mathrm{\ensuremath{\Omega}}$, thereby destroying interference between different durations. An inaccurate weakly coupled clock leaves the interference almost intact, and the need to resolve the resulting ``which way?'' problem is one of the main difficulties at the center of the ``tunnelling time'' controversy. In the absence of a probability distribution for the values of $\ensuremath{\tau}$, the SWP results are expressed in terms of moduli of the ``complex times,'' given by the weighted sums of the corresponding probability amplitudes. It is shown that overinterpretation of these results, by treating the SWP times as physical time intervals, leads to paradoxes and should be avoided. We also analyze various settings of the SWP clock, different calibration procedures, and the relation between the SWP results and the quantum dwell time. The cases of stationary tunneling and tunnel ionization are considered in some detail. Although our detailed analysis addresses only one particular definition of the duration of a tunneling process, it also points towards the impossibility of uniting various time parameters, which may occur in quantum theory, within the concept of a single tunnelling time.
Abstract Quantum tunnelling is a fundamental phenomenon in quantum physics, yet the question of how long it takes for a particle to tunnel through a barrier remains a topic of ongoing debate. Recent advances in attoclock experimental techniques in strong-field physics have renewed interest in this topic. While various definitions of tunneling time have been proposed, a consensus has yet to be reached. In this study, we adopt a definition of tunnelling time based on the ratio of the barrier width to the expected value of the velocity operator within the barrier. This approach reduces to the Büttiker-Landauer time (τBL\tau_{BL}τBL​) in the case of an opaque barrier and offers a clear physical interpretation for very thin barriers, where τBL\tau_{BL}τBL​ may not be well-defined. Additionally, by utilizing a virtual detector at the tunnel exit, we calculate the time delay between the peak of the electric field and the moment of ionization for long wavelengths ($\geq$6 μ\muμm). Our findings indicate that the time delay stabilizes around 190 as, remaining independent of the laser wavelength. Furthermore, through our quantum tunnelling time definition, this time delay can be interpreted as the time required for the electron to tunnel from a point within the barrier to the exit.