Since the pioneering work of Ramsey, atom interferometers are employed for precision metrology, in particular to measure time and to realize the second. In a classical interferometer, an ensemble of atoms is prepared in one of the two input states, whereas the second one is left empty. In this case, the vacuum noise restricts the precision of the interferometer to the standard quantum limit (SQL). Here, we propose and experimentally demonstrate a novel clock configuration that surpasses the SQL by squeezing the vacuum in the empty input state. We create a squeezed vacuum state containing an average of 0.75 atoms to improve the clock sensitivity of 10000 atoms by 2.05_{-0.37}^{+0.34} dB. The SQL poses a significant limitation for today's microwave fountain clocks, which serve as the main time reference. We evaluate the major technical limitations and challenges for devising a next generation of fountain clocks based on atomic squeezed vacuum.
Since the pioneering work of Ramsey, atom interferometers are employed for precision metrology, in particular to measure time and to realize the second. In a classical interferometer, an ensemble of atoms is prepared in one of the two input states, whereas the second one is left empty. In this case, the vacuum noise restricts the precision of the interferometer to the standard quantum limit (SQL). Here, we propose and experimentally demonstrate a novel clock configuration that surpasses the SQL by squeezing the vacuum in the empty input state. We create a squeezed vacuum state containing an average of 0.75 atoms to improve the clock sensitivity of 10000 atoms by 2.05_{-0.37}^{+0.34} dB. The SQL poses a significant limitation for today's microwave fountain clocks, which serve as the main time reference. We evaluate the major technical limitations and challenges for devising a next generation of fountain clocks based on atomic squeezed vacuum.
Since the pioneering work of Ramsey, atom interferometers are employed for precision metrology, in particular to measure time and to realize the second. In a classical interferometer, an ensemble of atoms is prepared in one of the two input states, whereas the second one is left empty. In this case, the vacuum noise restricts the precision of the interferometer to the standard quantum limit (SQL). Here, we propose and experimentally demonstrate a novel clock configuration that surpasses the SQL by squeezing the vacuum in the empty input state. We create a squeezed vacuum state containing an average of 0.75 atoms to improve the clock sensitivity of 10,000 atoms by 2.05 dB. The SQL poses a significant limitation for today's microwave fountain clocks, which serve as the main time reference. We evaluate the major technical limitations and challenges for devising a next generation of fountain clocks based on atomic squeezed vacuum.
Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.
Atomic clocks have reached the Standard Quantum Limit (SQL) of precision,1 set by the projection noise inherent in measurements on uncorrelated atoms. It is possible to overcome this limit by entangling the atoms to generate a "squeezed state" of the atomic ensemble. We use the collective interaction of an atomic ensemble with a far-detuned light field in an optical resonator to prepare squeezed states by two different methods: quantum non-demolition (QND) measurement and Hamiltonian evolution. We apply both methods to an ensemble of 5 x 104 87Rb atoms in a superposition of hyperfine clock states. We measure the suppression of projection noise and compare it to the accompanying reduction in signal, thereby quantifying the net gain in spectroscopic sensitivity. By QND measurement, with resolution up to 9 dB below the projection noise level, we achieve 3.0(8) dB of metrologically relevant squeezing. Whereas the measurement-based approach relies on knowledge of the (randomly distributed) measurement outcome to produce a conditionally squeezed state, the method of Hamiltonian evolution produces a known squeezed state independent of detector performance. We mimic the dynamics of the one-axis twisting Hamiltonian, proposed as a generator of squeezed states by Kitagawa and Ueda,2 by using the atom-induced frequency shift of the resonator mode and the corresponding resonator-field-induced shift of the atomic transition frequency to introduce an effective interaction among the atoms. The resulting deterministic squeezing is sufficient to allow a 6.0(4) dB improvement in spectroscopic sensitivity over the SQL.
Spin squeezing can improve atomic precision measurements beyond the standard quantum limit (SQL), and unitary spin squeezing is essential for improving atomic clocks. We report substantial and nearly unitary spin squeezing in ^{171}Yb, an optical lattice clock atom. The collective nuclear spin of ∼10^{3} atoms is squeezed by cavity feedback, using light detuned from the system's resonances to attain unitarity. The observed precision gain over the SQL is limited by state readout to 6.5(4) dB, while the generated states offer a gain of 12.9(6) dB, limited by the curvature of the Bloch sphere. Using a squeezed state within 30% of unitarity, we demonstrate an interferometer that improves the averaging time over the SQL by a factor of 3.7(2). In the future, the squeezing can be simply transferred onto the optical-clock transition of ^{171}Yb.
State of the art atomic sensors operate near the standard quantum limit (SQL) of projection noise, and overcoming this limit by using atom-atom entanglement such as spin squeezing is a major goal in quantum metrology. By coupling an ensemble of approximately 1000 Yb-171 atoms to a high-finesse asymmetric micromirror cavity with single-atom cooperativity of 1.8., we produce a near-unitary spin squeezed state. The observed spin noise suppression and metrological gain are limited by the state readout to 9.4(4) dB and 6.5(4) dB, respectively, while the generated states offer a spin noise suppression of 15.9(6) dB and a metrological gain of 12.9(6) dB over the standard quantum limit, limited by the curvature of the Bloch sphere. When requiring the squeezing process to be within 30% of unitarity, we demonstrate an interferometer that improves the averaging time over the SQL by a factor of 3.7(2).
Quantum Sensors, like atom interferometers (AI), can be employed for high-precision measurements of inertial forces, including their application as gravimeters, gradiometers, accelerometers, and gyroscopes. Their measurement principle relies on ultracold atoms that are prepared in quantum-mechanical superposition states in external degrees of freedom. These states can be prepared by a momentum transfer of a Raman laser. Then the superposition state senses the effect of an inertial force, which induce a corresponding relative phase. The phase is read out by a final coupling which converts the interferometric phase into a atom number difference between the two states. The difference provides an estimate of the interferometric phase and the corresponding quantity of interest. The quantum mechanical noise of the atomic ensemble cause a fundamental uncertainty of this estimation, which I analyze for generic AIs. For small atomic densities, the quantum phase noise of the ensemble limits the interferometric sensitivity. For large densities, quantum number fluctuations generate density fluctuations, which generates phase noise. I show that these two competing effects result in an optimal atom number with a maximal interferometer resolution. Squeezed atomic samples allow for a reduction of the quantum noise of one quantity at the expense of an increased noise along of a conjugate quantity. Phase and number are such quantities which obey to a variant of Heisenberg’s uncertainty principle. Neither phase nor number squeezing can improve the maximal interferometer resolution. As one main result of this thesis, I show how an optimal squeezing in between number and phase squeezing, allows for a fundamental improvement. I evaluate possible experimental paths to implement the proposed protocol. Concepts for a squeezing-enhanced operation of external-degree AIs have not yet been demonstrated. I propose and implement an atomic gravimeter, which is designed to accept spin-squeezed atomic states as input states. The interferometer is designed such that the interferometer couplings are performed in spin space, while the phase accumulation is performed in momentum states. For this interferometer, the squeezed input can be directly obtained from spin dynamics in spinor Bose-Einstein condensates. The main noise contributions in the experiment are analyzed, which results in a factor of 84 above the relevant quantum limit, preventing a squeezing enhancement so far. I outline a suppression of the main noise source, uncontrolled AC Stark shift on the squeezed mode and propose future important applications, including test of spontaneous collapse theories and an improvement of large-scale, high-precision gradiometers.