We measured the branching fractions for the decay of the 5p 2 P 1/2 state of 88 Sr + by applying a recently demonstrated photon-counting sequential method (M. Ramm et al., Phys. Rev. Lett. 111, 023004) to a single ion laser-cooled in a micro fabricated surface trap. The branching fraction for the decay into the 5s 2 S 1/2 ground level was found to be p = 0.9453 +0.0007 −0.0005. This result is in good agreement with recent theoretical calculations but disagrees with previous experimental measurements, however affected by a one order of magnitude larger uncertainty. This experiment also demonstrates the reliability and the performances of ion micro trap technology in the domain of precision measurements and spectroscopy. PACS numbers: 32.70.Cs, 06.30.Ft, 37.10.Ty
We present a measurement of the branching ratios from the
6P3∕2 state of
BaII into all dipole-allowed decay channels (
6S1∕2,
5D3∕2, and
5D5∕2). Measurements were performed on single
138Ba+ ions in a linear Paul trap with a frequency-doubled mode-locked Ti:sapphire laser resonant with the $6{S}_{1∕2}\ensuremath{\rightarrow}6{P}_{3∕2}$ transition at
455nm by detection of electron shelving into the dark
5D5∕2 state. By driving a $\ensuremath{\pi}$ Rabi rotation with a single femtosecond pulse, an absolute measurement of the branching ratio to
5D5∕2 state was performed. Combined with a measurement of the relative decay rates into
5D3∕2 and
5D5∕2 states performed with long trains of highly attenuated
455nm pulses, it allowed the extraction of the absolute ratios of the other two decays. Relative strengths normalized to unity are found to be $0.756\ifmmode\pm\else\textpm\fi{}0.046$, $0.0290\ifmmode\pm\else\textpm\fi{}0.0015$, and $0.215\ifmmode\pm\else\textpm\fi{}0.0064$ for
6S1∕2,
5D3∕2, and
5D5∕2, respectively. This approximately constitutes a threefold improvement over the best previous measurements and is a sufficient level of precision to compare to calculated values for dipole matrix elements.
We measured the branching fractions for the decay of the
5p2P1/2 state of
88Sr+ by applying a recently demonstrated photon-counting sequential method [M. Ramm, T. Pruttivarasin, M. Kokish, I. Talukdar, and H. H\"affner, Phys. Rev. Lett. 111, 023004 (2013)] to a single ion laser cooled in a microfabricated surface trap. The branching fraction for the decay into the
5s2S1/2 ground level was found to be
p=0.9449(5). This result is in good agreement with recent theoretical calculations but disagrees with previous experimental measurements, however affected by a one-order-of-magnitude larger uncertainty. This experiment demonstrates that microtrap technology is also applicable in the domain of precision measurements and spectroscopy.
We present a method for measuring branching fractions for the decay of J=1/2 atomic energy levels to lower-lying states based on time-resolved recording of the atom's fluorescence during a series of population transfers. We apply this method to measure the branching fractions for the decay of the 4²P(1/2) state of 40Ca+ to the 4²S(1/2) and 3²D(3/2) states to be 0.935 65(7) and 0.064 35(7), respectively. The measurement scheme requires that at least one of the lower-lying states be long lived. The method is insensitive to fluctuations in laser light intensity and magnetic field and is readily applicable to various atomic species due to its simplicity. Our result distinguishes well among existing state-of-the-art theoretical models of Ca+.
In the field of quantum metrology, transition matrix elements are crucial for accurately evaluating the black-body radiation shift of the clock transition and the amplitude of the related parity-violating transition, and can be used as probes to test quantum electrodynamic effects, especially at the 10−3–10−4 level. We developed a universal experimental approach to precisely determine the dipole transition matrix elements by using the shelving technique, for the species where two transition channels are involved, in which the excitation pulses with increasing duration were utilized to induce shelving, and the resulting shelving probabilities were determined by counting the scattered photons from the excited P1/22 state to the S1/22 ground state. Using the scattered photons offers several advantages, including insensitivity to fluctuations in magnetic field, laser intensity, and frequency detuning. An intensity-alternating sequence to minimize detection noise and a real-time approach for background photon correction were implemented in parallel. We applied this technique to a single Yb+ ion, and determined the 6p P1/22-5d D23/2 transition matrix element 2.9979(20) ea0, which indicates an order of magnitude improvement over existing reports. By combining our result with the 6p P1/22 lifetime of 8.12(2) ns, we extracted the 6s S1/22-6p P1/22 transition matrix element to be 2.4703(31) ea0. The accurately determined dipole transition matrix elements can serve as a benchmark for the development of high-precision atomic many-body theoretical methods.
Optical lattice clocks based on the narrow ( 5 s 2 ) S 0 1 − ( 5 s 5 p ) P 0 3 transition in neutral strontium (Sr) are among the most precise and accurate measurement devices in existence. Although this transition is completely forbidden by selection rules, state mixing from the hyperfine interaction in Sr 87 provides a weakly allowed transition that can be coherently driven with practical clock laser intensities. While the coherent interrogation times of optical clocks are typically set by the linewidth of the probe laser, this limitation can be overcome in synchronous differential comparisons between ensembles. In such measurements the natural lifetime of the S 0 1 – P 0 3 clock transition becomes the fundamental limiting factor to the duration of a single run of the experiment. However, a direct measurement of the decay rate of the clock excited state is quite challenging due to the competing effects of other loss channels such as Raman scattering, inelastic collisions, and atom loss due to background gas. In this work, we monitor the decay of Sr atoms trapped in an optical lattice and initialized in the P 0 3 state. By making measurements of high and low density ensembles of both Sr 87 and Sr 88 across varying lattice trap depths, we isolate radiative decay, which accounts for a significant fraction of the observed decays at low depths. We obtain a natural radiative decay lifetime of 167 − 40 + 79 s for the P 0 3 clock state in Sr 87 , a value that is consistent with previously reported measurements and theoretical predictions. We also introduce an additional measurement scheme that involves repeated measurements of the ground-state population within a single experimental sequence, validating our model and the consistency of the measured rates. We expect that the techniques introduced in this work are applicable to lifetime measurements of long-lived metastable states in other atoms and ions used for clocks and quantum computing. The results presented in this work inform performance estimates of proposed gravitational wave detectors and long-baseline atom interferometers making use of Sr 87 .