Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1605.03799 · Journal of Modern Optics

Conservative classical and quantum resolution limits for incoherent imaging

Mankei Tsang

Published Sep 18, 2017• 41 citations
arXivHTMLPDF

Abstract

I propose classical and quantum limits to the statistical resolution of two incoherent optical point sources from the perspective of minimax parameter estimation. Unlike earlier results based on the Cramér-Rao bound (CRB), the limits proposed here, based on the worst-case error criterion and a Bayesian version of the CRB, are valid for any biased or unbiased estimator and obey photon-number scalings that are consistent with the behaviours of actual estimators. These results prove that, from the minimax perspective, the spatial-mode demultiplexing measurement scheme recently proposed by Tsang, Nair, and Lu [Phys. Rev. X 2016, 6 031033.] remains superior to direct imaging for sufficiently high photon numbers.

DOI
10.1080/09500340.2017.1377306

Related papers

Experimental Separation Estimation of Incoherent Optical Sources Reaching the Cramér-Rao Bound

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1]–[3]. Our experimental setup (see Fig. 1 (left)) allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 26, 2023•1 citation

Passive optical superresolution at the quantum limit

A. I. Lvovsky, Michael R. Grace, Saikat Guha +3 more

For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.

quant-pharXiv:2605.10767•Optica•May 12, 2026•14 citations

Experimental separation estimation of incoherent optical sources reaching the (quantum) Cramér-Rao bound

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1–3]. Our experimental setup allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].

Photonics North (PN)•Jun 12, 2023•0 citations

Semiparametric bounds for subdiffraction incoherent optical imaging: a parametric-submodel approach

Mankei Tsang

I derive classical and quantum lower error bounds for moment estimation in subdiffraction incoherent optical imaging. While the end results are similar to earlier ones [Tsang, Phys. Rev. Res. 1, 033006 (2019); Phys. Rev. A 99, 012305 (2019)], the present work avoids the flawed mathematical assumptions in the earlier works by adopting a parametric-submodel approach from semiparametric statistics. With the rigorous bounds at hand and redefining the parameter of interest, I show that an alternative measurement called spatial-mode demultiplexing (SPADE) is superior to ideal direct imaging for a subdiffraction object, even if SPADE can measure only a finite number of modes.

•Oct 7, 2020•2 citations

Quantum limit for two-dimensional resolution of two incoherent optical point sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.

arXiv:1606.00603•Physical Review A•Jun 29, 2017•107 citations

Quantum limit to subdiffraction incoherent optical imaging. II. A parametric-submodel approach

Mankei Tsang

In a previous paper [M. Tsang, Phys. Rev. A 99, 012305 (2019)], I proposed a quantum limit to the estimation of object moments in subdiffraction incoherent optical imaging. In this sequel, I prove the quantum limit rigorously by infinite-dimensional analysis. A key to the proof is the choice of an unfavorable parametric submodel to give a bound for the semiparametric problem. By generalizing the quantum limit for a larger class of moments, I also prove that the measurement method of spatial-mode demultiplexing with just one or two modes is able to achieve the quantum limit. For comparison, I derive a classical bound for direct imaging using the parametric-submodel approach, which suggests that direct imaging is substantially inferior.

arXiv:2010.03518•Physical Review A•Nov 10, 2021•18 citations
I propose classical and quantum limits to the statistical resolution of two incoherent optical point sources from the perspective of minimax parameter estimation. Unlike earlier results based on the Cramér-Rao bound (CRB), the limits proposed here, based on the worst-case error criterion and a Bayesian version of the CRB, are valid for any biased or unbiased estimator and obey photon-number scalings that are consistent with the behaviours of actual estimators. These results prove that, from the minimax perspective, the spatial-mode demultiplexing measurement scheme recently proposed by Tsang, Nair, and Lu [Phys. Rev. X 2016, 6 031033.] remains superior to direct imaging for sufficiently high photon numbers.
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1]–[3]. Our experimental setup (see Fig. 1 (left)) allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].
For more than a century, the diffraction limit has defined the resolution achievable by passive optical imaging systems. Although some resolution improvement can be gained through classical data processing of the image, it is limited by the noise arising from quantum nature of light. Minimizing the effect of this noise requires quantum treatment of optical imaging. By reformulating imaging as a problem of quantum measurement and estimation, it becomes possible to identify optimal detection strategies that recover spatial information previously thought inaccessible. This review summarizes the theoretical framework that underpins this development, from the formulation of quantum Cramer-Rao bounds and Chernoff bounds to the construction of receivers that attain them, such as those based on spatial-mode demultiplexing. We show how these methods can beat conventional imaging in the classification, localization, and imaging of sub-Rayleigh incoherent sources. We then discuss extensions to multiparameter and partially coherent scenarios, and highlight the unifying connections between estimation and discrimination tasks. Finally, we survey recent experimental demonstrations that approach quantum-limited resolution and outline emerging applications in microscopy, astronomy, and optical sensing.
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1–3]. Our experimental setup allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].
I derive classical and quantum lower error bounds for moment estimation in subdiffraction incoherent optical imaging. While the end results are similar to earlier ones [Tsang, Phys. Rev. Res. 1, 033006 (2019); Phys. Rev. A 99, 012305 (2019)], the present work avoids the flawed mathematical assumptions in the earlier works by adopting a parametric-submodel approach from semiparametric statistics. With the rigorous bounds at hand and redefining the parameter of interest, I show that an alternative measurement called spatial-mode demultiplexing (SPADE) is superior to ideal direct imaging for a subdiffraction object, even if SPADE can measure only a finite number of modes.
We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the xxx and yyy components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.
In a previous paper [M. Tsang, Phys. Rev. A 99, 012305 (2019)], I proposed a quantum limit to the estimation of object moments in subdiffraction incoherent optical imaging. In this sequel, I prove the quantum limit rigorously by infinite-dimensional analysis. A key to the proof is the choice of an unfavorable parametric submodel to give a bound for the semiparametric problem. By generalizing the quantum limit for a larger class of moments, I also prove that the measurement method of spatial-mode demultiplexing with just one or two modes is able to achieve the quantum limit. For comparison, I derive a classical bound for direct imaging using the parametric-submodel approach, which suggests that direct imaging is substantially inferior.