Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1603.06008 · Physical Review A

What happens in a measurement?

Steven Weinberg

Published Mar 18, 2016• 33 citations
arXivHTMLPDF

Abstract

It is assumed that in a measurement the system under study interacts with a macroscopic measuring apparatus, in such a way that the density matrix of the measured system evolves according to the Lindblad equation. Under an assumption of nondecreasing von Neumann entropy, conditions on the operators appearing in this equation are given that are necessary and sufficient for the late-time limit of the density matrix to take the form appropriate for a measurement. Where these conditions are satisfied, the Lindblad equation can be solved explicitly. The probabilities appearing in the late-time limit of this general solution are found to agree with the Born rule, and are independent of the details of the operators in the Lindblad equation.

DOI
10.1103/physreva.93.032124

Related papers

Necessary and Sufficient Condition on the Lindblad Equation to Prevent Entropy Increase

Steven Weinberg

It is shown that in order for the solutions of the Lindblad equation never to give a decreasing von Neumann entropy, it is necessary and sufficient that the operators appearing in this equation should be unitary linear combinations of their adjoints. In this case, these operators may be replaced with Hermitian operators, without changing the evolution of density matrices.

arXiv:1511.06016•Nov 18, 2015•0 citations

Timeless Histories: Quantum Measurement and the Maximum Entropy Principle

Alexei V. Tkachenko

The quantum measurement problem, i.e., the apparent conflict between unitary quantum evolution and non-unitary, stochastic wave-function collapse, remains unresolved a century after the formulation of quantum mechanics. We first review the standard picture, from the Copenhagen prescription with its Heisenberg cut, through von Neumann's movable cut, to environment-induced decoherence, which explains the emergence of stable classical records but still presupposes the Born rule and therefore cannot by itself replace the measurement postulates. We then connect this problem to the Maximum Entropy Principle in two complementary ways. First, decoherence drives the measurement apparatus toward the least biased state compatible with the dynamically protected pointer distribution, so that the emergent collapse may be viewed as a thermodynamic relaxation toward constrained maximum entropy. Second, we propose a Timeless Histories formulation of quantum mechanics in which the primitive objects are ordered sequences of events rather than evolving wave functions. Their conditional probabilities are assigned, relative to specified refinements, by a single Born-Boltzmann rule that combines the quadratic structure of Born's rule with Boltzmann's counting of equally probable microstates. The textbook form of Born's rule, the projection postulate, density operators, and wave functions are then recovered as derived informational constructs, while collapse becomes Bayesian conditioning on recorded events. Time and space enter only subsequently through unitary translation symmetry. Since the probability rule is postulated without reference to any physical collapse or classical observer, the usual circularity of the decoherence program is avoided. Decoherence can then be invoked to explain the stability and approximate additivity of macroscopic records, i.e., the emergence of classicality.

arXiv:2311.04893•Entropy•Sep 22, 2026•0 citations

Why state of quantum system is fully defined by density matrix

A. V. Nenashev

We show that probabilities of results of all possible measurements performing on a quantum system depend on the system's state only through its density matrix. Therefore all experimentally available information about the state contains in the density matrix. In this study, we do not postulate that measurements obey some given formalism (such as observables, positive-operator valued measures, etc.), and do not use Born rule. The process of measurement is considered in a fully operational manner---as an interaction of a measured system with some black-box apparatus. The key point of our approach is the proof that, for improper mixtures, the expected value of any measurement depends linearly on the reduced density function. Such a proof is achieved by considering appropriate thought experiments. We demonstrate that Born rule can be derived as a natural consequence of our results.

arXiv:1601.08205•Jan 29, 2016•4 citations

Problems of Quantum Measurement

Joseph F. Johnson

We derive the probabilities of measurement results from Schroedinger's equation plus a definition of macroscopic as a particular kind of thermodynamic limit. Bohr's insight that a measurement apparatus must be classical in nature and classically describable is made precise in a mathematical sense analogous to the procedures of classical statistical mechanics and the study of Hamiltonian heat baths.

arXiv:quant-ph/0502124•Feb 21, 2005•1 citation

Quantum clock and Newtonian time

Dorje C. Brody, Lane P. Hughston

An extension of standard quantum mechanics is proposed in which the Newtonian time appearing as a parameter in the unitary evolution operator is replaced with the time shown by a `quantum clock'. Such a clock is defined by the following properties: (a) the time that the clock shows is nondecreasing, (b) the clock ticks at random Newtonian times with random tick sizes, and (c) on average the clock shows the Newtonian time. We show that the leading term in the evolution equation for the density matrix associated with any quantum clock gives the von Neumann equation. The leading correction to the von Neumann equation is given by the Lindblad equation generated by the Hamiltonian, but there are higher-order terms that generalize the von Neumann equation and the Lindblad terms. Modifications to the von Neumann equation are worked out in detail in a parametric family of models for which the tick sizes are gamma distributed. Lower bounds on the parameters of these quantum clock models are derived using the precision limit of an atomic clock. An anomalous term in the Ehrenfest theorem for a free particle is derived, which in principle can be used as a basis for testing such models.

quant-pharXiv:2602.02077•Feb 3, 2026•0 citations

Open quantum systems and the grand canonical ensemble

Benedikt M. Reible, Luigi Delle Site

The celebrated Lindblad equation governs the nonunitary time evolution of density operators used in the description of open quantum systems. It is usually derived from the von Neumann equation for a large system, at given physical conditions, when a small subsystem is explicitly singled out and the rest of the system acts as an environment whose degrees of freedom are traced out. In the specific case of a subsystem with variable particle number, the equilibrium density operator is given by the well-known grand canonical Gibbs state. Consequently, solving the Lindblad equation in this case should automatically yield, without any additional assumptions, the corresponding density operator in the limiting case of statistical equilibrium. Current studies of the Lindblad equation with varying particle number assume, however, the grand canonical Gibbs state a priori: the chemical potential is externally imposed rather than derived from first principles, and hence the corresponding density operator is not obtained as a natural solution of the equation. In this work, we investigate the compatibility of grand canonical statistical mechanics with the derivation of the Lindblad equation. We propose an alternative and complementary approach to the current literature that consists in using a generalized system Hamiltonian which includes a term μN. In a previous paper, this empirically well-known term has been formally derived from the von Neumann equation for the specific case of equilibrium. Including μN in the system Hamiltonian leads to a modified Lindblad equation which yields the grand canonical state as a natural solution, meaning that all the quantities involved are obtained from the physics of the system without any external assumptions.

arXiv:2508.16985•Physical review. E•Aug 7, 2025•3 citations
It is assumed that in a measurement the system under study interacts with a macroscopic measuring apparatus, in such a way that the density matrix of the measured system evolves according to the Lindblad equation. Under an assumption of nondecreasing von Neumann entropy, conditions on the operators appearing in this equation are given that are necessary and sufficient for the late-time limit of the density matrix to take the form appropriate for a measurement. Where these conditions are satisfied, the Lindblad equation can be solved explicitly. The probabilities appearing in the late-time limit of this general solution are found to agree with the Born rule, and are independent of the details of the operators in the Lindblad equation.
The quantum measurement problem, i.e., the apparent conflict between unitary quantum evolution and non-unitary, stochastic wave-function collapse, remains unresolved a century after the formulation of quantum mechanics. We first review the standard picture, from the Copenhagen prescription with its Heisenberg cut, through von Neumann's movable cut, to environment-induced decoherence, which explains the emergence of stable classical records but still presupposes the Born rule and therefore cannot by itself replace the measurement postulates. We then connect this problem to the Maximum Entropy Principle in two complementary ways. First, decoherence drives the measurement apparatus toward the least biased state compatible with the dynamically protected pointer distribution, so that the emergent collapse may be viewed as a thermodynamic relaxation toward constrained maximum entropy. Second, we propose a Timeless Histories formulation of quantum mechanics in which the primitive objects are ordered sequences of events rather than evolving wave functions. Their conditional probabilities are assigned, relative to specified refinements, by a single Born-Boltzmann rule that combines the quadratic structure of Born's rule with Boltzmann's counting of equally probable microstates. The textbook form of Born's rule, the projection postulate, density operators, and wave functions are then recovered as derived informational constructs, while collapse becomes Bayesian conditioning on recorded events. Time and space enter only subsequently through unitary translation symmetry. Since the probability rule is postulated without reference to any physical collapse or classical observer, the usual circularity of the decoherence program is avoided. Decoherence can then be invoked to explain the stability and approximate additivity of macroscopic records, i.e., the emergence of classicality.
We show that probabilities of results of all possible measurements performing on a quantum system depend on the system's state only through its density matrix. Therefore all experimentally available information about the state contains in the density matrix. In this study, we do not postulate that measurements obey some given formalism (such as observables, positive-operator valued measures, etc.), and do not use Born rule. The process of measurement is considered in a fully operational manner---as an interaction of a measured system with some black-box apparatus. The key point of our approach is the proof that, for improper mixtures, the expected value of any measurement depends linearly on the reduced density function. Such a proof is achieved by considering appropriate thought experiments. We demonstrate that Born rule can be derived as a natural consequence of our results.
An extension of standard quantum mechanics is proposed in which the Newtonian time appearing as a parameter in the unitary evolution operator is replaced with the time shown by a `quantum clock'. Such a clock is defined by the following properties: (a) the time that the clock shows is nondecreasing, (b) the clock ticks at random Newtonian times with random tick sizes, and (c) on average the clock shows the Newtonian time. We show that the leading term in the evolution equation for the density matrix associated with any quantum clock gives the von Neumann equation. The leading correction to the von Neumann equation is given by the Lindblad equation generated by the Hamiltonian, but there are higher-order terms that generalize the von Neumann equation and the Lindblad terms. Modifications to the von Neumann equation are worked out in detail in a parametric family of models for which the tick sizes are gamma distributed. Lower bounds on the parameters of these quantum clock models are derived using the precision limit of an atomic clock. An anomalous term in the Ehrenfest theorem for a free particle is derived, which in principle can be used as a basis for testing such models.
The celebrated Lindblad equation governs the nonunitary time evolution of density operators used in the description of open quantum systems. It is usually derived from the von Neumann equation for a large system, at given physical conditions, when a small subsystem is explicitly singled out and the rest of the system acts as an environment whose degrees of freedom are traced out. In the specific case of a subsystem with variable particle number, the equilibrium density operator is given by the well-known grand canonical Gibbs state. Consequently, solving the Lindblad equation in this case should automatically yield, without any additional assumptions, the corresponding density operator in the limiting case of statistical equilibrium. Current studies of the Lindblad equation with varying particle number assume, however, the grand canonical Gibbs state a priori: the chemical potential is externally imposed rather than derived from first principles, and hence the corresponding density operator is not obtained as a natural solution of the equation. In this work, we investigate the compatibility of grand canonical statistical mechanics with the derivation of the Lindblad equation. We propose an alternative and complementary approach to the current literature that consists in using a generalized system Hamiltonian which includes a term μN. In a previous paper, this empirically well-known term has been formally derived from the von Neumann equation for the specific case of equilibrium. Including μN in the system Hamiltonian leads to a modified Lindblad equation which yields the grand canonical state as a natural solution, meaning that all the quantities involved are obtained from the physics of the system without any external assumptions.