Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1602.05987 · American Journal of Physics

Video recording true single-photon double-slit interference

Reuben S. Aspden, Miles J. Padgett, Gabriel C. Spalding

Published Aug 19, 2016• 85 citations
arXivHTMLPDF

Abstract

Commercially available cameras do not have a low-enough dark noise to directly capture double-slit interference at the single photon level. In this work, camera noise levels are significantly reduced by activating the camera only when the presence of a photon has been detected by the independent detection of a time-correlated photon produced via parametric down-conversion. This triggering scheme provides the improvement required for direct video imaging of Young's double-slit experiment with single photons, allowing clarified versions of this foundational demonstration. We present video data of the evolving interference patterns. Also, we introduce variations on this experiment aimed at promoting discussion of the role spatial coherence plays in such a measurement, emphasizing complementary aspects of single-photon measurement and highlighting the roles of transverse position and momentum correlations between down-converted photons, including examples of “ghost” imaging and diffraction.

DOI
10.1119/1.4955173

Related papers

Young's double-slit interference demonstration with single photons

B. Luo, Leia Francis, Valeria Rodríguez-Fajardo +2 more

The interference of single photons going through a double slit is a compelling demonstration of the wave and particle nature of light in the same experiment. Single photons produced by spontaneous parametric down-conversion can be used for this purpose. However, it is particularly challenging to implement this due to coherency and resolution challenges. In this article, we present a table-top laboratory arrangement suitable for the undergraduate instruction laboratory that overcomes these challenges. The apparatus scans a single detector to produce a plot showing the interference patterns of single photons. We include experimental data obtained using this setup, demonstrating double-slit and single-slit interference as well as quantum erasing through the use of sheet polarizers.

arXiv:2401.02351•American Journal of Physics•Mar 21, 2024•14 citations

Wave/particle nature of light - towards a double-doubleslit experiment

Tsewang Gyatso, E Baudin, Emmanuel Schenck +2 more

Full text: We present two experiments on single- and two-particle interference. In the single-photon interference experiment, photons from a spontaneous parametric down-conversion (SPDC) source are send through a double slit. An interference pattern is built up frame by frame from shots obtained with an EMCCD camera behind the slit. Each frame contains on average less than one photon, thus demonstrating true single-photon sensitivity of the camera. The build-up of the interference pattern nicely demonstrates the concept of wave-particle duality. In a next step, we describe the Heisenberg's lens experiment and present the conditions required to analyse and investigate the spatial correlations of momentum entangled photons produced by SPDC. The occurrence of double-slit interference now depends on the experimental arrangement for the second photon of the pair, for example: interference can only occur if the second photon is also passing a double slit. We present an analysis of such a double-double-slit experiment. (author)

•Jul 1, 2005•0 citations

Observation of Two-Photon “Ghost” Interference and Diffraction

Dmitry Strekalov, Alexander V. Sergienko, Давид Николаевич Клышко +1 more

Observations of unusual diffraction and interference by two-photon correlation measurements are reported. The signal and idler beams produced by spontaneous parametric down-conversion are sent in different directions, and detected by two distant pointlike photon counting detectors. A double slit or a single slit is inserted into the signal beam. Interference-diffraction patterns are observed in coincidences by scanning the detector in the idler beam.

Physical Review Letters•May 1, 1995•892 citations

Contagem de fótons únicos com CCD em experimentos de óptica quântica

Lucas Paresqui Berruezo

In this work we discuss topics such as the theory of photon detectors, showing its operation mode, characteristics and types. In addition, we also study the quantum detection theory, how photons interact with the detector's atoms, and how the process of single and coincidences counting mode works. We look into the theory of parametric down conversion in order to create a correlated photon source and a single photon source. We also discuss about ghost imaging theory and experiments, since it shows us in a very clear way a direct appplication for a single photons camera. I present the results obtained so far with the camera we have in our laboratory. We detected the photon's cones generated by the parametric down conversion type I and type II. We recorded interference patterns, multiple slit images, and amplitude masks images with few photons. We used the CCD for photon counting in an experiment where an image of an object is obtained through photons that have not interacted with the object, but is part of one of the beams in the stimulated parametric down conversion. One of the great motivators of working with a camera is performing quantum optics experiments where spatial patterns are detected. In this aspect a camera has a greater robustness than single photon APD since it allows us to observe the whole transverse profile of a beam simultaneously, something that is possible only with a set of detectors APDs.

•Aug 4, 2017•0 citations

EPR-based ghost imaging using a single-photon-sensitive camera

Reuben S. Aspden, D. S. Tasca, Robert W. Boyd +1 more

Correlated photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments, two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated photon ghost imaging experiments have scanned a single-pixel detector through the field of view to obtain spatial information. However, scanning leads to poor sampling efficiency, which scales inversely with the number of pixels, N , in the image. In this work, we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far field of the photon pair source, taking advantage of the Einstein–Podolsky–Rosen-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.

arXiv:1212.5059•New Journal of Physics•Jul 17, 2013•169 citations

Heralded single-photon ghost imaging

Reuben S. Aspden, D. S. Tasca, Robert W. Boyd +1 more

Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.

•Dec 20, 2012•1 citation
Commercially available cameras do not have a low-enough dark noise to directly capture double-slit interference at the single photon level. In this work, camera noise levels are significantly reduced by activating the camera only when the presence of a photon has been detected by the independent detection of a time-correlated photon produced via parametric down-conversion. This triggering scheme provides the improvement required for direct video imaging of Young's double-slit experiment with single photons, allowing clarified versions of this foundational demonstration. We present video data of the evolving interference patterns. Also, we introduce variations on this experiment aimed at promoting discussion of the role spatial coherence plays in such a measurement, emphasizing complementary aspects of single-photon measurement and highlighting the roles of transverse position and momentum correlations between down-converted photons, including examples of “ghost” imaging and diffraction.
The interference of single photons going through a double slit is a compelling demonstration of the wave and particle nature of light in the same experiment. Single photons produced by spontaneous parametric down-conversion can be used for this purpose. However, it is particularly challenging to implement this due to coherency and resolution challenges. In this article, we present a table-top laboratory arrangement suitable for the undergraduate instruction laboratory that overcomes these challenges. The apparatus scans a single detector to produce a plot showing the interference patterns of single photons. We include experimental data obtained using this setup, demonstrating double-slit and single-slit interference as well as quantum erasing through the use of sheet polarizers.
Full text: We present two experiments on single- and two-particle interference. In the single-photon interference experiment, photons from a spontaneous parametric down-conversion (SPDC) source are send through a double slit. An interference pattern is built up frame by frame from shots obtained with an EMCCD camera behind the slit. Each frame contains on average less than one photon, thus demonstrating true single-photon sensitivity of the camera. The build-up of the interference pattern nicely demonstrates the concept of wave-particle duality. In a next step, we describe the Heisenberg's lens experiment and present the conditions required to analyse and investigate the spatial correlations of momentum entangled photons produced by SPDC. The occurrence of double-slit interference now depends on the experimental arrangement for the second photon of the pair, for example: interference can only occur if the second photon is also passing a double slit. We present an analysis of such a double-double-slit experiment. (author)
In this work we discuss topics such as the theory of photon detectors, showing its operation mode, characteristics and types. In addition, we also study the quantum detection theory, how photons interact with the detector's atoms, and how the process of single and coincidences counting mode works. We look into the theory of parametric down conversion in order to create a correlated photon source and a single photon source. We also discuss about ghost imaging theory and experiments, since it shows us in a very clear way a direct appplication for a single photons camera. I present the results obtained so far with the camera we have in our laboratory. We detected the photon's cones generated by the parametric down conversion type I and type II. We recorded interference patterns, multiple slit images, and amplitude masks images with few photons. We used the CCD for photon counting in an experiment where an image of an object is obtained through photons that have not interacted with the object, but is part of one of the beams in the stimulated parametric down conversion. One of the great motivators of working with a camera is performing quantum optics experiments where spatial patterns are detected. In this aspect a camera has a greater robustness than single photon APD since it allows us to observe the whole transverse profile of a beam simultaneously, something that is possible only with a set of detectors APDs.
Correlated photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments, two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated photon ghost imaging experiments have scanned a single-pixel detector through the field of view to obtain spatial information. However, scanning leads to poor sampling efficiency, which scales inversely with the number of pixels, N , in the image. In this work, we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far field of the photon pair source, taking advantage of the Einstein–Podolsky–Rosen-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.
Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.