Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1602.05344 · Physical Review A

Standard quantum limit of angular motion of a suspended mirror and homodyne detection of a ponderomotively squeezed vacuum field

Yutaro Enomoto, Koji Nagano, Seiji Kawamura

Published Jul 20, 2016• 15 citations
arXivHTMLPDF

Abstract

Compared to the quantum noise in the measurement of the translational motion of a suspended mirror using laser light, the quantum noise in the measurement of the angular motion of a suspended mirror has not been investigated intensively despite its potential importance. In this article, an expression for the quantum noise in the angular motion measurement is explicitly derived. The expression indicates that one quadrature of the vacuum field of the first-order Hermite-Gaussian mode of light causes quantum sensing noise and the other causes quantum back-action noise, or in other words the first-order vacuum field is ponderomotively squeezed. It is also shown that the Gouy phase shift the light acquires between the mirror and the position of detection of the light corresponds to the homodyne angle. Therefore, the quantum back-action noise can be canceled and the standard quantum limit can be surpassed by choosing the appropriate position of detection analogously to the cancellation of quantum radiation pressure noise by choosing an appropriate homodyne angle.

DOI
10.1103/physreva.94.012115

Related papers

Quantum limitations and back action evading measurements in classical force and rotation detection

Andrey B. Matsko, Sergey P. Vyatchanin, Anatoliy A. Savchenkov +1 more

We theoretically study both the technical and the fundamental quantum limitations of the sensitivity of a resonant optical gyroscope based on a high finesse optical cavity. We show that the quantum back action associated with the resonantly enhanced optical cross and self-phase modulation results in the nonlinear optics-mediated standard quantum limit (SQL) of the angle random walk of the gyroscope. We also found that the measurement sensitivity of a generic optical gyroscope is fundamentally limited due to the opto-mechanical properties of the device. Ponderomotive action of the light interrogating the gyroscope cavity leads to the opto-mechanical SQL of the rotation angle detection. The uncorrelated quantum fluctuations of power of clockwise and counterclockwise light waves result in optical power-dependent uncertainty of the angular gyroscope position.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•1 citation

Quantum noise in the position measurement of a cavity mirror undergoing Brownian motion

Kurt A. Jacobs, Ilkka Juhani Tittonen, Howard M. Wiseman +1 more

We perform a quantum theoretical calculation of the noise power spectrum for a phase measurement of the light output from a coherently driven optical cavity with a freely moving rear mirror. We examine how the noise resulting from the quantum back action appears among the various contributions from other noise sources. We do not assume an ideal (homodyne) phase measurement, but rather consider phase-modulation detection, which we show has a different shot noise level. We also take into account the effects of thermal damping of the mirror, losses within the cavity, and classical laser noise. We relate our theoretical results to experimental parameters, so as to make direct comparisons with current experiments simple. We also show that in this situation, the standard Brownian motion master equation is inadequate for describing the thermal damping of the mirror, as it produces a spurious term in the steady-state phase-fluctuation spectrum. The corrected Brownian motion master equation [L. Diosi, Europhys. Lett. 22, 1 (1993)] rectifies this inadequacy.

arXiv:quant-ph/9902040•Physical Review A•Jul 1, 1999•60 citations

Observation of radiation-pressure effects and back-action cancellation in interferometric measurements

A. Heidmann, T. Caniard, P. Verlot +2 more

Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very highfinesse optical cavity the displacements of a mirror with a sensitivity at the 10-20 m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already report the first experimental demonstration of a back-action noise cancellation. Using a classical radiation-pressure noise to mimic the quantum noise of light, we have observed a drastic improvement of sensitivity both in position and force measurements.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 8, 2008•0 citations

Experimental Demonstration of a Classical Analog to Quantum Noise Cancellation for Use in Gravitational Wave Detection

Conor M Mow-Lowry, Benjamin Sheard, M. Gray +2 more

We present results that are a classical analog to quantum noise cancellation. It is possible to breach the standard quantum limit in an interferometer by the use of squeezing to correlate orthogonal quadratures of quantum noise, causing their effects on the resulting sensitivity to cancel. A laser beam incident on a Fabry-Perot cavity was imprinted with classical, correlated noise in the same quadratures that cause shot noise and radiation pressure noise. Couplings between these quadratures due to a movable mirror, sensitive to radiation pressure, cause the excess classical noise to cancel. This cancellation was shown to improve the signal to noise ratio of an injected signal by approximately a factor of 10.

Physical Review Letters•Apr 23, 2004•33 citations

Force metrology using quantum correlations of light due to a room-temperature mechanical oscillator

Vivishek Sudhir, Ryan Schilling, Sergey A. Fedorov +3 more

The radiation pressure interaction of light with a mechanical oscillator leads to a fundamental disturbance on the oscillator. This disturbance - measurement backaction - is due to the quantum fluctuations in the amplitude of the light. When the phase of the light is detected to infer the mechanical position, quantum fluctuations in the phase - measurement imprecision - leads to a further uncertainty in the estimate of the position. In this conventional measurement strategy, these two noise sources impose a fundamental limit on the ability to estimate the position of the mechanical object - the so-called standard quantum limit [1]. However, the two noise contributions are in general correlated. The fluctuations in the amplitude quadrature drive the mechanical oscillator, and this backaction driven motion is transduced into the phase quadrature. Correlations thus established [2] form a valuable quantum mechanical resource that can be directly employed for back-action cancellation in the measurement record via “variational measurements” [3].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•1 citation

Vacuum state squeezing versus squeezed classical noise: a test using conditional homodyne detection

H. J. Carmichael

Measurement of the squeezed fluctuations of an optical field by the method of conditional homodyne detection is discussed. It is shown that conditional homodyne detection is able to distinguish qualitatively between vacuum-state squeezing and squeezed classical noise. Whereas for conventional squeezed-light detection, only a quantitative distinction can be made, based on the setting of the shot-noise level, under conditional detection, the presence of classical noise changes the actual shape of the measured correlation function. The correlations show a positive peak due to the unsqeezed classical noise frequencies, set inside the negative dip associated with the squeezed fluctuations. The width in time of the positive peak is the larger of the detector response time and the inverse of the classical noise bandwidth. The fundamental distinction between vacuum-state squeezing and squeezed classical noise is that there is no positive peak, even in the limiting form of a delta-function, when the unsqueezed frequencies correspond to vacuum state modes. Implications for the literal interpretation of vacuum fluctuations, such as is adopted in stochastic electrodynamics, are discussed. The ideas are presented in general terms and illustrated by an example which treats the generation and detection of broadband squeezed light, including finite-bandwidth classical noise, within the framework of the quantum trajectory theory of cascaded open systems.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 16, 2003•1 citation
Compared to the quantum noise in the measurement of the translational motion of a suspended mirror using laser light, the quantum noise in the measurement of the angular motion of a suspended mirror has not been investigated intensively despite its potential importance. In this article, an expression for the quantum noise in the angular motion measurement is explicitly derived. The expression indicates that one quadrature of the vacuum field of the first-order Hermite-Gaussian mode of light causes quantum sensing noise and the other causes quantum back-action noise, or in other words the first-order vacuum field is ponderomotively squeezed. It is also shown that the Gouy phase shift the light acquires between the mirror and the position of detection of the light corresponds to the homodyne angle. Therefore, the quantum back-action noise can be canceled and the standard quantum limit can be surpassed by choosing the appropriate position of detection analogously to the cancellation of quantum radiation pressure noise by choosing an appropriate homodyne angle.
We theoretically study both the technical and the fundamental quantum limitations of the sensitivity of a resonant optical gyroscope based on a high finesse optical cavity. We show that the quantum back action associated with the resonantly enhanced optical cross and self-phase modulation results in the nonlinear optics-mediated standard quantum limit (SQL) of the angle random walk of the gyroscope. We also found that the measurement sensitivity of a generic optical gyroscope is fundamentally limited due to the opto-mechanical properties of the device. Ponderomotive action of the light interrogating the gyroscope cavity leads to the opto-mechanical SQL of the rotation angle detection. The uncorrelated quantum fluctuations of power of clockwise and counterclockwise light waves result in optical power-dependent uncertainty of the angular gyroscope position.
We perform a quantum theoretical calculation of the noise power spectrum for a phase measurement of the light output from a coherently driven optical cavity with a freely moving rear mirror. We examine how the noise resulting from the quantum back action appears among the various contributions from other noise sources. We do not assume an ideal (homodyne) phase measurement, but rather consider phase-modulation detection, which we show has a different shot noise level. We also take into account the effects of thermal damping of the mirror, losses within the cavity, and classical laser noise. We relate our theoretical results to experimental parameters, so as to make direct comparisons with current experiments simple. We also show that in this situation, the standard Brownian motion master equation is inadequate for describing the thermal damping of the mirror, as it produces a spurious term in the steady-state phase-fluctuation spectrum. The corrected Brownian motion master equation [L. Diosi, Europhys. Lett. 22, 1 (1993)] rectifies this inadequacy.
Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very highfinesse optical cavity the displacements of a mirror with a sensitivity at the 10-20 m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already report the first experimental demonstration of a back-action noise cancellation. Using a classical radiation-pressure noise to mimic the quantum noise of light, we have observed a drastic improvement of sensitivity both in position and force measurements.
We present results that are a classical analog to quantum noise cancellation. It is possible to breach the standard quantum limit in an interferometer by the use of squeezing to correlate orthogonal quadratures of quantum noise, causing their effects on the resulting sensitivity to cancel. A laser beam incident on a Fabry-Perot cavity was imprinted with classical, correlated noise in the same quadratures that cause shot noise and radiation pressure noise. Couplings between these quadratures due to a movable mirror, sensitive to radiation pressure, cause the excess classical noise to cancel. This cancellation was shown to improve the signal to noise ratio of an injected signal by approximately a factor of 10.
The radiation pressure interaction of light with a mechanical oscillator leads to a fundamental disturbance on the oscillator. This disturbance - measurement backaction - is due to the quantum fluctuations in the amplitude of the light. When the phase of the light is detected to infer the mechanical position, quantum fluctuations in the phase - measurement imprecision - leads to a further uncertainty in the estimate of the position. In this conventional measurement strategy, these two noise sources impose a fundamental limit on the ability to estimate the position of the mechanical object - the so-called standard quantum limit [1]. However, the two noise contributions are in general correlated. The fluctuations in the amplitude quadrature drive the mechanical oscillator, and this backaction driven motion is transduced into the phase quadrature. Correlations thus established [2] form a valuable quantum mechanical resource that can be directly employed for back-action cancellation in the measurement record via “variational measurements” [3].
Measurement of the squeezed fluctuations of an optical field by the method of conditional homodyne detection is discussed. It is shown that conditional homodyne detection is able to distinguish qualitatively between vacuum-state squeezing and squeezed classical noise. Whereas for conventional squeezed-light detection, only a quantitative distinction can be made, based on the setting of the shot-noise level, under conditional detection, the presence of classical noise changes the actual shape of the measured correlation function. The correlations show a positive peak due to the unsqeezed classical noise frequencies, set inside the negative dip associated with the squeezed fluctuations. The width in time of the positive peak is the larger of the detector response time and the inverse of the classical noise bandwidth. The fundamental distinction between vacuum-state squeezing and squeezed classical noise is that there is no positive peak, even in the limiting form of a delta-function, when the unsqueezed frequencies correspond to vacuum state modes. Implications for the literal interpretation of vacuum fluctuations, such as is adopted in stochastic electrodynamics, are discussed. The ideas are presented in general terms and illustrated by an example which treats the generation and detection of broadband squeezed light, including finite-bandwidth classical noise, within the framework of the quantum trajectory theory of cascaded open systems.