Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1602.00331 · Physical Review A

Synthetic frequency protocol for Ramsey spectroscopy of clock transitions

Valeriy I. Yudin, A. V. Taǐchenachev, M. Yu. Basalaev, T. Zanon-Willette

Published Nov 7, 2016• 29 citations
arXivHTMLPDF

Abstract

We develop a universal method to significantly suppress probe-induced shifts in any type of atomic clock using Ramsey spectroscopy. Our approach is based on the adaptation of the synthetic frequency concept [V. I. Yudin et al., Phys. Rev. Lett. 107, 030801 (2011)] (previously developed for blackbody radiation shift suppression) to Ramsey spectroscopy with the use of interrogations with different dark time intervals. The most significant suppression of the shift is obtained in combination with the so-called hyper-Ramsey spectroscopy technique [V. I. Yudin et al., Phys. Rev. A 82, 011804(R) (2010)]. In this case, the probe-induced frequency shifts can be suppressed considerably from metrologically significant levels to below a fractional level of ${10}^{\ensuremath{-}18}$ for practically any optical atomic clocks. The main advantage of our method in comparison with other hyper-Ramsey approaches [R. Hobson et al., Phys. Rev. A 93, 010501(R) (2016); T. Zanon-Willette et al., Phys. Rev. A 93, 042506 (2016)] derives from its much greater efficiency and robustness in the presence of decoherence.

DOI
10.1103/physreva.94.052505

Related papers

Synthetic frequency protocol in the Ramsey spectroscopy

Valeriy I. Yudin, M. Yu. Basalaev, А. В. Тайченачев

We develop an universal method to significantly suppress probe-induced shifts in any types of atomic clocks using the Ramsey spectroscopy. The frequency shifts can be suppressed considerably below a fractional level of 10 −18 practically for any optical atomic clocks.

Journal of Physics Conference Series•Jan 1, 2017•1 citation

Optical-clock local-oscillator universal interrogation protocol for zero probe-field-induced frequency-shifts

T. Zanon-Willette, R. Lefèvre, А. В. Тайченачев +1 more

Optical clock interrogation protocols, based on laser-pulse spectroscopy, are suffering from probe-induced frequency-shifts and their variations induced by laser power. Original Hyper-Ramsey probing scheme, which was proposed to alleviate those issues, does not apply below fractional frequency changes of 10-18when decoherence and relaxation by spontaneous emission or collisions are present. We present a universal interrogation protocol based on composite laser-pulses spectroscopy with phase-modulation for both fermionic and bosonic optical clocks, eliminating probe-induced frequency-shifts at all orders even in presence of various dissipative processes. This scheme, using a magic combination of ±π/4 and ±3π/4 phase-modulated generalized Hyper-Ramsey resonances, extremely robust to errors in laser parameters, can be applied to atomic, molecular and nuclear frequency metrology, mass spectrometry and precision spectroscopy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations

Hyper-Ramsey spectroscopy of optical clock transitions

Valeriy I. Yudin, А. В. Тайченачев, Chris W. Oates +6 more

We present nonstandard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties can be radically suppressed (by two to four orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly benefit from this method. In the latter case, these frequency shifts can be suppressed considerably below a fractional level of $10$${}^{\ensuremath{-}17}$. Moreover, our approach opens the door for high-precision optical clocks based on direct frequency comb spectroscopy.

arXiv:0910.5948•Physical Review A•Jul 22, 2010•144 citations

Combined error signal in Ramsey spectroscopy of clock transitions

V I Yudin, A V Taichenachev, M. Yu. Basalaev +7 more

We have developed a universal method to form the reference signal for the stabilization of arbitrary atomic clocks based on Ramsey spectroscopy. Our approach uses an interrogation scheme of the atomic system with two different Ramsey periods and a specially constructed combined error signal (CES) computed by subtracting two error signals with the appropriate calibration factor. CES spectroscopy allows for perfect elimination of probe-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors and other imperfections of the interrogation procedure. The method is simpler than recently developed auto-balanced Ramsey spectroscopy techniques (Sanner et al 2018 Phys. Rev. Lett. 120 053602; Yudin et al 2018 Phys. Rev. Appl. 9 054034), because it uses a single error signal that feeds back on the clock frequency. The use of CES is a general technique that can be applied to many applications of precision spectroscopy.

arXiv:1807.10158•New Journal of Physics•Nov 28, 2018•26 citations

Modified hyper-Ramsey methods for the elimination of probe shifts in optical clocks

Richard Hobson, William Bowden, S. A. King +3 more

We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in the probe shift. We experimentally investigate the scheme using the magnetically induced ${}^{1}{S}_{0}\text{\ensuremath{-}}{}^{3}{P}_{0}$ transition in $^{88}\mathrm{Sr}$, demonstrating automatic suppression of a sizable $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$ probe Stark shift to below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ even with very large errors in shift compensation.

arXiv:1510.08144•Physical Review A•Jan 19, 2016•52 citations

Atomic Clocks with Suppressed Blackbody Radiation Shift

Valeriy I. Yudin, А. В. Тайченачев, Maksim V. Okhapkin +6 more

We develop a concept of atomic clocks where the blackbody radiation shift and its fluctuations can be suppressed by 1--3 orders of magnitude independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies ${\ensuremath{\nu}}_{1}$ and ${\ensuremath{\nu}}_{2}$) which are exposed to the same thermal environment, there exists a ``synthetic'' frequency ${\ensuremath{\nu}}_{\mathrm{syn}}$ $\ensuremath{\propto}$ (${\ensuremath{\nu}}_{1}\ensuremath{-}{\ensuremath{\epsilon}}_{12}{\ensuremath{\nu}}_{2}$) largely immune to the blackbody radiation shift. For example, in the case of $^{171}\mathrm{Yb}^{+}$ it is possible to create a synthetic-frequency-based clock in which the fractional blackbody radiation shift can be suppressed to the level of ${10}^{\ensuremath{-}18}$ in a broad interval near room temperature ($300\ifmmode\pm\else\textpm\fi{}15\text{ }\text{ }\mathrm{K}$). We also propose a realization of our method with the use of an optical frequency comb generator stabilized to both frequencies ${\ensuremath{\nu}}_{1}$ and ${\ensuremath{\nu}}_{2}$, where the frequency ${\ensuremath{\nu}}_{\mathrm{syn}}$ is generated as one of the components of the comb spectrum.

arXiv:1103.0760•Physical Review Letters•Jul 14, 2011•49 citations
We develop a universal method to significantly suppress probe-induced shifts in any type of atomic clock using Ramsey spectroscopy. Our approach is based on the adaptation of the synthetic frequency concept [V. I. Yudin et al., Phys. Rev. Lett. 107, 030801 (2011)] (previously developed for blackbody radiation shift suppression) to Ramsey spectroscopy with the use of interrogations with different dark time intervals. The most significant suppression of the shift is obtained in combination with the so-called hyper-Ramsey spectroscopy technique [V. I. Yudin et al., Phys. Rev. A 82, 011804(R) (2010)]. In this case, the probe-induced frequency shifts can be suppressed considerably from metrologically significant levels to below a fractional level of 10\ensuremath−18{10}^{\ensuremath{-}18}10\ensuremath−18 for practically any optical atomic clocks. The main advantage of our method in comparison with other hyper-Ramsey approaches [R. Hobson et al., Phys. Rev. A 93, 010501(R) (2016); T. Zanon-Willette et al., Phys. Rev. A 93, 042506 (2016)] derives from its much greater efficiency and robustness in the presence of decoherence.
Optical clock interrogation protocols, based on laser-pulse spectroscopy, are suffering from probe-induced frequency-shifts and their variations induced by laser power. Original Hyper-Ramsey probing scheme, which was proposed to alleviate those issues, does not apply below fractional frequency changes of 10-18when decoherence and relaxation by spontaneous emission or collisions are present. We present a universal interrogation protocol based on composite laser-pulses spectroscopy with phase-modulation for both fermionic and bosonic optical clocks, eliminating probe-induced frequency-shifts at all orders even in presence of various dissipative processes. This scheme, using a magic combination of ±π/4 and ±3π/4 phase-modulated generalized Hyper-Ramsey resonances, extremely robust to errors in laser parameters, can be applied to atomic, molecular and nuclear frequency metrology, mass spectrometry and precision spectroscopy.
We present nonstandard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties can be radically suppressed (by two to four orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly benefit from this method. In the latter case, these frequency shifts can be suppressed considerably below a fractional level of 101010${}^{\ensuremath{-}17}$. Moreover, our approach opens the door for high-precision optical clocks based on direct frequency comb spectroscopy.
We have developed a universal method to form the reference signal for the stabilization of arbitrary atomic clocks based on Ramsey spectroscopy. Our approach uses an interrogation scheme of the atomic system with two different Ramsey periods and a specially constructed combined error signal (CES) computed by subtracting two error signals with the appropriate calibration factor. CES spectroscopy allows for perfect elimination of probe-induced light shifts and does not suffer from the effects of relaxation, time-dependent pulse fluctuations and phase-jump modulation errors and other imperfections of the interrogation procedure. The method is simpler than recently developed auto-balanced Ramsey spectroscopy techniques (Sanner et al 2018 Phys. Rev. Lett. 120 053602; Yudin et al 2018 Phys. Rev. Appl. 9 054034), because it uses a single error signal that feeds back on the clock frequency. The use of CES is a general technique that can be applied to many applications of precision spectroscopy.
We develop a method of modified hyper-Ramsey spectroscopy in optical clocks, achieving complete immunity to the frequency shifts induced by the probing fields themselves. Using particular pulse sequences with tailored phases, frequencies, and durations, we can derive an error signal centered exactly at the unperturbed atomic resonance with a steep discriminant which is robust against variations in the probe shift. We experimentally investigate the scheme using the magnetically induced ${}^{1}{S}_{0}\text{\ensuremath{-}}{}^{3}{P}_{0}$ transition in 88Sr^{88}\mathrm{Sr}88Sr, demonstrating automatic suppression of a sizable $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$ probe Stark shift to below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ even with very large errors in shift compensation.
We develop a concept of atomic clocks where the blackbody radiation shift and its fluctuations can be suppressed by 1--3 orders of magnitude independent of the environmental temperature. The suppression is based on the fact that in a system with two accessible clock transitions (with frequencies ${\ensuremath{\nu}}_{1}$ and ${\ensuremath{\nu}}_{2}$) which are exposed to the same thermal environment, there exists a ``synthetic'' frequency ${\ensuremath{\nu}}_{\mathrm{syn}}$ $\ensuremath{\propto}$ (${\ensuremath{\nu}}_{1}\ensuremath{-}{\ensuremath{\epsilon}}_{12}{\ensuremath{\nu}}_{2}$) largely immune to the blackbody radiation shift. For example, in the case of 171Yb+^{171}\mathrm{Yb}^{+}171Yb+ it is possible to create a synthetic-frequency-based clock in which the fractional blackbody radiation shift can be suppressed to the level of ${10}^{\ensuremath{-}18}$ in a broad interval near room temperature ($300\ifmmode\pm\else\textpm\fi{}15\text{ }\text{ }\mathrm{K}$). We also propose a realization of our method with the use of an optical frequency comb generator stabilized to both frequencies ${\ensuremath{\nu}}_{1}$ and ${\ensuremath{\nu}}_{2}$, where the frequency ${\ensuremath{\nu}}_{\mathrm{syn}}$ is generated as one of the components of the comb spectrum.