We address the precision of optical interferometers fed by quantum and semiclassical Gaussian states involving passive and/or active elements, such as beam splitters, photodetectors, and optical parametric amplifiers. We first address the ultimate bounds to precision by discussing the behavior of the quantum Fisher information. We then consider photodetection at the output and calculate the sensitivity of the interferometers taking into account the nonunit quantum efficiency of the detectors. Our results show that in the ideal case of photon number detectors with unit quantum efficiency the best configuration is the symmetric one, namely, a passive (active) interferometer with a passive (active) detection stage: in this case one may achieve Heisenberg scaling of sensitivity by suitably optimizing over Gaussian states at the input. On the other hand, in the realistic case of detectors with nonunit quantum efficiency, the performances of the passive scheme are unavoidably degraded, whereas detectors involving optical parametric amplifiers allow us to fully compensate for the presence of loss in the detection stage, thus restoring the Heisenberg scaling.
We address the precision of optical interferometers fed by quantum and semiclassical Gaussian states involving passive and/or active elements, such as beam splitters, photodetectors, and optical parametric amplifiers. We first address the ultimate bounds to precision by discussing the behavior of the quantum Fisher information. We then consider photodetection at the output and calculate the sensitivity of the interferometers taking into account the nonunit quantum efficiency of the detectors. Our results show that in the ideal case of photon number detectors with unit quantum efficiency the best configuration is the symmetric one, namely, a passive (active) interferometer with a passive (active) detection stage: in this case one may achieve Heisenberg scaling of sensitivity by suitably optimizing over Gaussian states at the input. On the other hand, in the realistic case of detectors with nonunit quantum efficiency, the performances of the passive scheme are unavoidably degraded, whereas detectors involving optical parametric amplifiers allow us to fully compensate for the presence of loss in the detection stage, thus restoring the Heisenberg scaling.
We consider an interferometer that contains active elements, such as a parametric amplifier, with general two-mode Gaussian unitary channels rather than the usually considered phase-shift channel. We concentrate on a scheme based on the recently proposed pumped-up SU(1,1) active interferometer where all input particles participate in the parameter estimation, and from which a conventional SU(1,1) interferometer is a limiting case. Using the covariance matrix formalism, we derive the quantum Fisher information of this active interferometer with a general two-mode Gaussian unitary channel, as well as the sensitivity for a number-sum measurement scheme, finding simple expressions for the latter. As an example application, we apply our results to Bose-Einstein condensates (BECs), and in particular a BEC gravitational-wave detector based on resonance, finding that the sensitivity of the detector can be improved by several orders of magnitude with this new interferometry scheme.
We revisit Mach—Zehnder interferometry using a suitable phase-space analysis and present a rigorous optimization of the sensitivity in realistic condition, i.e., for Gaussian input states, and taking into account nonunit quantum efficiency in the detection stage. The working regime of the interferometer is optimized at fixed input energy versus the squeezing phases and amplitudes as well as the distribution of squeezing in the two input signals. For ideal detection we find the known result that the squeezing resource allows to beat the shot-noise limit. For nonunit detection efficiency, we show that for fixed input energy one can always optimize the squeezing fraction in order to enhance the sensitivity with respect to the case of no squeezing, even in cases when one cannot go beyond the shot-noise limit.
The fundamental precision limit of an interferometer is crucial since it bounds the best possible sensitivity one could achieve using such a device. This thesis will focus on several different interferometers and try to give the ultimate precision bounds by carefully counting all the resources used in the interferometers. The thesis begins with the basics of the quantum state of light. The fundamentals of quantum metrology are also reviewed and discussed. More specifically, the terminology of classical and quantum Cram\'er-Rao bound and classical and quantum Fisher information are introduced. Chapter 3 discusses the conclusive precision bounds in two-mode interferometer such as Mach-Zehnder interferometer (MZI) and SU(1,1) interferometer. I revisit the quantum Fisher information approach of these two interferometers and show the discrepancy of phase sensitivity on the physically same setup. Then I establish fundamental precision estimation bounds for such device, due to the reason that many works of literature fail to accurately count the resources and knowledge of phase-to-be-estimated used in the interferometers. The analysis suggests that for a MZI, one can never do better than SNL in phase sensitivity, when an input to one of the two ports is the vacuum. If one does not allow the detector to use any external phase reference or power resource, then the precision is limited by the SNL. For a SU(1,1) interferometer, firstly, when one of the input states is restricted to be a vacuum state, I showed that by using either the phase-averaging method or the quantum Fisher information matrix method, different phase configurations of the SU(1,1) interferometer result in the same QFI. Secondly, I compared the results of the phase-averaging method and the quantum Fisher information matrix method, and then I argued that for an SU(1,1) interferometer, phase averaging or quantum Fisher information matrix method is generally required, and they are equivalent. Finally, I used the quantum Fisher information matrix method to calculate the precision limit for other common input states, such as two coherent state inputs or coherent state with squeezed vacuum inputs. In chapter 4, I will consider a passive multi-mode interferometer for multiparameter phase estimation. It was suggested that optical networks with relatively inexpensive overhead---single photon Fock states, passive optical elements, and single photon detection---can show significant improvements over classical strategies for single-parameter estimation, when the number of modes in the network is small. In this chapter, I analytically compute the quantum Cramer-Rao bound to show these
We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We find the ultimate limit of precision for such an interferometer by calculating the quantum Fisher information of the mixed quantum state in one of the interferometer's outputs about the difference phase. We show that, in the vicinity of the black fringe, this information is asymptotically close to the quantum Fisher information about this phase for the two-mode readout. We conclude that the single-mode readout is optimal for phase estimation in squeezing-enhanced interferometry and allows for the Heisenberg scaling of precision. We also show that the optimal local measurement in the vicinity of the black fringe consists of amplifying the output field in a phase-sensitive way and measuring its photon number.
It is known that non-Gaussian and only non-Gaussian quantum states can be orthogonal to other quantum states. We show here that, due to this feature, using the non-Gaussian (Fock or Schrödinger cat) states of the probing light, it is possible to detect a given phase shift in optical interferometers with vanishing error probability. Squeezing of the probing non-Gaussian quantum state at the input of the interferometer and the proportional anti-squeezing at the output state allow for the improvement of the sensitivity proportionally to the squeeze factor. The optical losses, most notably the non-ideal quantum efficiency of the photodetection, degrade the sensitivity, introducing finite “false positive” and “false negative” detection errors. However, using state-of-the-art photon-number-resolving detectors, it is still possible to obtain smaller detection error probabilities than in the case of Gaussian quantum states.