arXiv:1412.8630 · Optics Letters

Positive operator-valued measure reconstruction of a beam-splitter tree-based photon-number-resolving detector

Fabrizio Piacentini, M. P. Levi, Alessio Avella, Marco López, S. Kück, Sergey V. Polyakov, Ivo Pietro Degiovanni, G. Brida, Marco Genovese

Published Mar 29, 2015• 18 citations
arXivHTMLPDF

Abstract

Here we present a reconstruction of the positive operator-value measurement of a photon-number-resolving detector comprised of three 50∶50 beam-splitters in a tree configuration, terminated with four single-photon avalanche detectors. The four detectors' outputs are processed by an electronic board that discriminates detected photon number states from 0 to 4 and implements a "smart counting" routine to compensate for dead time issues at high count rates.

DOI
10.1364/ol.40.001548

Related papers

Number-state reconstruction with a single SPAD

Patrick Banner, Deniz Kurdak, Yaxin Li +3 more

Single-photon avalanche detectors (SPADs) are used ubiquitously in optical and quantum science, but they are not photon-number-resolving detectors. Despite this, in this work we present preliminary results that show that a single SPAD can still be used to perform number-state reconstruction. Through detector characterization and use of maximum-likelihood analysis, we perform number-state reconstruction with a single SPAD and obtain good agreement with independently measured distributions for both Poissonian and anti-bunched light. Our method works well for photon rates up to roughly one input photon per dead time as well as pulse lengths and correlation times of at least a few dead times, fitting many of today’s quantum optics experiments.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Number-state reconstruction with a single single-photon avalanche detector

Patrick Banner, Deniz Kurdak, Yaxin Li +3 more

Single-photon avalanche detectors (SPADs) are crucial sensors of light for many fields and applications. However, they are not able to resolve photon number, so typically more complex and more expensive experimental setups or devices must be used to measure the number of photons in a pulse. Here, we present a methodology for performing photon number-state reconstruction with only one SPAD. The methodology, which is cost-effective and easy to implement, uses maximum-likelihood techniques with a detector model whose parameters are measurable. We achieve excellent agreement between known input pulses and their reconstructions for coherent states with up to ≈10 photons and peak input photon rates up to several Mcounts/s. When detector imperfections are small, we maintain good agreement for coherent pulses with peak input photon rates of over 40 Mcounts/s, greater than one photon per detector dead time. For anti-bunched light, the reconstructed and independently measured pulse-averaged values of g (2) (0) are also consistent with one another. Our algorithm is applicable to light pulses whose pulse width and correlation time scales are both at least a few detector dead times. These results, achieved with single commercially available SPADs, provide an inexpensive number-state reconstruction method and expand the capabilities of single-photon detectors.

arXiv:2308.13603•Optica Quantum•Mar 6, 2024•8 citations

Photon-number-resolving segmented detectors based on single-photon avalanche-photodiodes

Rajveer Nehra, Chun-Hung Chang, Qianhuan Yu +2 more

We investigate the feasibility and performance of photon-number-resolved photodetection employing single-photon avalanche photodiodes (SPADs) with low dark counts. While the main idea, to split n photons into m detection modes with a vanishing probability of more than one photon per mode, is not new, we investigate here a important variant of this situation where SPADs are side-coupled to the same waveguide rather than terminally coupled to a propagation tree. This prevents the nonideal SPAD quantum efficiency from contributing to photon loss. We propose a concrete SPAD segmented waveguide detector based on a vertical directional coupler design, and characterize its performance by evaluating the purities of Positive-Operator-Valued Measures (POVMs) in terms of number of SPADs, photon loss, dark counts, and electrical cross-talk.

arXiv:1708.09015•Optics Express•Jan 16, 2020•33 citations

Entanglement-assisted calibration of a photon-number-resolving detector

Fabrizio Piacentini, G. Brida, Luigi Ciavarella +7 more

Here we present the first experimental entanglement-assisted quantum char-acterization of an unknown photon-number-resolving detector, i.e. the reconstruction of its positive operator-valued measure (POVM), obtained by exploiting the quantum correlations of a twin-beam generated by parametric down conversion (PDC).

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations

Macroscopic photon counting beating the Poisson noise limit

Timon Schapeler, Fabian Schlue, Isabell Mischke +4 more

Photon counting is a cornerstone of quantum optics. Here, we demonstrate precisely counting from 0 to over 9000 photons, beating the Poisson noise limit by at least $4.1~\mathrm{dB}$ across this range. We achieve sub-single-photon precision up to 276 photons per pulse. To do so, we multiplex eight intrinsically photon-number-resolving superconducting nanowire single-photon detectors across 128 temporal modes. We use a model-informed characterization of each of the 1024 detection bins, for optimal precision. We perform quantum detector tomography to reconstruct the positive operator valued measures (POVMs) of the complete device, which consists of $1.38\cdot10^8$ matrix elements. At the repetition rate of our experiment of $80~\mathrm{kHz}$, we can precisely count photons corresponding to an optical power of approximately $71~\mathrm{pW}$, bridging the gap from single-photon measurements to high-sensitivity optical power meters. A photon-number-resolving detector of this size, and the tools used to analyze it, will become increasingly important to characterize large quantum states, as well as tasks in precision metrology and optical power standards.

quant-pharXiv:2604.27761•Optica•May 1, 2026•1 citation

Quantum state measurements using multipixel photon detectors

I. Afek, Adi Natan, O. Ambar +1 more

The characterization and conditional preparation of multiphoton quantum states require the use of photon-number resolving detectors. We study the use of detectors based on multiple avalanche photodiode pixels in this context. We develop a general model that provides the positive operator value measures for these detectors. The model incorporates the effect of cross talk between pixels which is unique to these devices. We validate the model by measuring coherent-state photon-number distributions and reconstructing them with high precision. Finally, we evaluate the suitability of such detectors for quantum state tomography and entanglement-based quantum state preparation, highlighting the effects of dark counts and cross talk between pixels.

arXiv:0903.1415•Physical Review A•Apr 28, 2009•90 citations
Here we present a reconstruction of the positive operator-value measurement of a photon-number-resolving detector comprised of three 50∶50 beam-splitters in a tree configuration, terminated with four single-photon avalanche detectors. The four detectors' outputs are processed by an electronic board that discriminates detected photon number states from 0 to 4 and implements a "smart counting" routine to compensate for dead time issues at high count rates.
Single-photon avalanche detectors (SPADs) are used ubiquitously in optical and quantum science, but they are not photon-number-resolving detectors. Despite this, in this work we present preliminary results that show that a single SPAD can still be used to perform number-state reconstruction. Through detector characterization and use of maximum-likelihood analysis, we perform number-state reconstruction with a single SPAD and obtain good agreement with independently measured distributions for both Poissonian and anti-bunched light. Our method works well for photon rates up to roughly one input photon per dead time as well as pulse lengths and correlation times of at least a few dead times, fitting many of today’s quantum optics experiments.
Single-photon avalanche detectors (SPADs) are crucial sensors of light for many fields and applications. However, they are not able to resolve photon number, so typically more complex and more expensive experimental setups or devices must be used to measure the number of photons in a pulse. Here, we present a methodology for performing photon number-state reconstruction with only one SPAD. The methodology, which is cost-effective and easy to implement, uses maximum-likelihood techniques with a detector model whose parameters are measurable. We achieve excellent agreement between known input pulses and their reconstructions for coherent states with up to ≈10 photons and peak input photon rates up to several Mcounts/s. When detector imperfections are small, we maintain good agreement for coherent pulses with peak input photon rates of over 40 Mcounts/s, greater than one photon per detector dead time. For anti-bunched light, the reconstructed and independently measured pulse-averaged values of g (2) (0) are also consistent with one another. Our algorithm is applicable to light pulses whose pulse width and correlation time scales are both at least a few detector dead times. These results, achieved with single commercially available SPADs, provide an inexpensive number-state reconstruction method and expand the capabilities of single-photon detectors.
We investigate the feasibility and performance of photon-number-resolved photodetection employing single-photon avalanche photodiodes (SPADs) with low dark counts. While the main idea, to split n photons into m detection modes with a vanishing probability of more than one photon per mode, is not new, we investigate here a important variant of this situation where SPADs are side-coupled to the same waveguide rather than terminally coupled to a propagation tree. This prevents the nonideal SPAD quantum efficiency from contributing to photon loss. We propose a concrete SPAD segmented waveguide detector based on a vertical directional coupler design, and characterize its performance by evaluating the purities of Positive-Operator-Valued Measures (POVMs) in terms of number of SPADs, photon loss, dark counts, and electrical cross-talk.
Photon counting is a cornerstone of quantum optics. Here, we demonstrate precisely counting from 0 to over 9000 photons, beating the Poisson noise limit by at least 4.1 dB4.1~\mathrm{dB}4.1 dB across this range. We achieve sub-single-photon precision up to 276 photons per pulse. To do so, we multiplex eight intrinsically photon-number-resolving superconducting nanowire single-photon detectors across 128 temporal modes. We use a model-informed characterization of each of the 1024 detection bins, for optimal precision. We perform quantum detector tomography to reconstruct the positive operator valued measures (POVMs) of the complete device, which consists of 1.38⋅1081.38\cdot10^81.38⋅108 matrix elements. At the repetition rate of our experiment of 80 kHz80~\mathrm{kHz}80 kHz, we can precisely count photons corresponding to an optical power of approximately 71 pW71~\mathrm{pW}71 pW, bridging the gap from single-photon measurements to high-sensitivity optical power meters. A photon-number-resolving detector of this size, and the tools used to analyze it, will become increasingly important to characterize large quantum states, as well as tasks in precision metrology and optical power standards.
The characterization and conditional preparation of multiphoton quantum states require the use of photon-number resolving detectors. We study the use of detectors based on multiple avalanche photodiode pixels in this context. We develop a general model that provides the positive operator value measures for these detectors. The model incorporates the effect of cross talk between pixels which is unique to these devices. We validate the model by measuring coherent-state photon-number distributions and reconstructing them with high precision. Finally, we evaluate the suitability of such detectors for quantum state tomography and entanglement-based quantum state preparation, highlighting the effects of dark counts and cross talk between pixels.