Superconducting hot-electron nanobolometer with microwave bias and readout

Artem A. Kuzmin, Michael Merker, S. V. Shitov, Nikolay N. Abramov, Andrey B. Ermakov, Matthias Arndt, S. Wünsch, K. Ilin, Alexey Vladimirovich Ustinov, M. Siegel

Published Dec 15, 2014• 0 citations
arXivHTMLPDF

Abstract

We propose a new detection technique based on radio-frequency (RF) bias and readout of an antenna-coupled superconducting nanobolometer. This approach is suitable for Frequency-Division-Multiplexing (FDM) readout of large arrays using broadband low-noise RF amplifier. We call this new detector RFTES. This feasibility study was made on demonstrator devices which are made in all-Nb technology and operate at 4.2 K. The studied RFTES devices consist of an antenna-coupled superconducting nanobolometer made of ultrathin niobium films with transition temperature Tc = 5.2 K. The 0.65-THz antenna and nanobolometer are embedded as a load into a GHz-range coplanar niobium resonator (Tc = 8.9 K, Q = 4000). To heat the superconducting Nb nanobolometer close to the Tc, the RF power at resonator frequency f = 5.8 GHz is applied via a transmission line which is weakly coupled (-11 dB) to the loaded resonator. The THz-antenna of RFTES was placed in the focus of a sapphire immersion lens inside a He4-cryostat equipped with an optical window and a semiconductor RF amplifier. We have demonstrated optical response of the RFTES to THz radiation. The demonstrator receiver system employing the RFTES device showed an optical Noise-Equivalent Power (NEP) 1e-14 W/sqrt(Hz) at 4.2 K.

DOI
10.48550/arxiv.1412.4502

Related papers

Superconducting noise bolometer with microwave bias and readout for array applications

Artem A. Kuzmin, Alexei D. Semenov, S. V. Shitov +4 more

We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a 1.0 × 0.5 μm2 micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ≈3 × 10−12 W/Hz1/2, which is close to expectations for this particular device in the noise-response regime.

arXiv:1709.02997•Applied Physics Letters•Jul 24, 2017•8 citations

Wide-Range Bolometer With RF Readout TES

S. V. Shitov, Michael Siegel, Nikolay N. Abramov +7 more

To improve both scalability and noise-filtering capability of a transition-edge sensor (TES), a new concept of a thin-film detector is suggested, which is based on embedding a microbridge TES into a high-Q planar GHz-range resonator weakly coupled to a 50-Ω-readout transmission line. Such a TES element is designed as a hot-electron microbolometer coupled to a THz-range antenna and as a load of the resonator at the same time. A weak THz signal coupled to the antenna heats the microbridge TES, thus reducing the quality factor of the resonator and leading to a power increment in the readout line. The power-to-power conversion gain, an essential figure of merit, is estimated to be above 10. To demonstrate the basic concept, we fabricated and tested a few submicrometer-sized devices from Nb thin films for operation temperature about 5 K. The dc and RF characterization of the new device is made at a resonator frequency about 5.8 GHz. A low-noise high-electron mobility transistor amplifier is used in our TES experiments without the need for a SQUID readout. The optical sensitivity to blackbody radiation within the frequency band 600-700 GHz ismeasured as (2.7 ± 0.9) × 10-14W/√Hz at Tc≈ 5 K at bath temperature ≈1.5 K.

arXiv:1412.5370•IEEE Transactions on Applied Superconductivity•Dec 22, 2014•7 citations

Superconducting metamaterial for sub-millimeter wave imaging: First light

Nikolay N. Abramov, Artem A. Kuzmin, S. V. Shitov +2 more

We present results of first experiments with elementary cells for detection of sub-millimeter-wave radiation. The cells realize frequency-division multiplexing (FDM) readout of an antenna coupled superconducting hot electron bolometers (HEB) by means of integrated GHz-range superconducting resonators. Such cells can be coupled to a single transmission line for FDM readout, forming a large format imaging metasurface. The design of metasurface, consisting of hexagonal clusters, is discussed and experimental results for both the single cell and the 7-element hexagonal cluster are presented. The prototypes have been fabricated using thin film Nb technology with TCof HEB bridges about 5 K and frequencies of resonators in 5-8 GHz range. Optical sensitivity measurements using a black body radiation source resulted in optical NEP of the cell about 3×10-14W/√Hz at ambient temperature 1.4 K.

International Congress on Advanced Electromagnetic Materials in Microwaves and Optics•Aug 1, 2014•0 citations

Terahertz (THz) direct detectors based on superconducting HEBs with thermal, THz and microwave biasing methods (Conference Presentation)

Jian Chen

Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.

Next-Generation Spectroscopic Technologies•May 14, 2019•0 citations

Terahertz Direct Detectors Based on Superconducting Hot Electron Bolometers With Different Biasing Methods

Runfeng Su, Yi Di Zhang, Xuecou Tu +6 more

Terahertz (THz) direct detectors based on superconducting niobium nitride hot electron bolometers with thermal, microwave and THz biasing methods have been studied at a frequency of 0.65 THz and at an operating temperature of 4.2 K. A low noise amplifier at room temperature is used to read out the current change of the detectors modulated by the chopping frequency at 732 Hz. The noise spectral density, current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the microwave and THz biasing methods have about one order higher current responsivity than that of the thermal one. With the microwave biasing, an optical NEP at the order of pW/√Hz which shows no deterioration is obtained by choosing the microwave frequency and power appropriately.

IEEE Transactions on Applied Superconductivity•Apr 22, 2019•13 citations

Superconducting RFTES Detector at Milli-Kelvin Temperatures

Alexey V. Merenkov, Vladimir I. Chichkov, Andrey B. Ermakov +2 more

We describe the first phase of experimental study of the superconducting bridge RFTES detector at temperatures 20-300 mK including the measurement of its thermal conductance, which fits the model of electron gas heating. We discuss the idea of the RFTES scheme, which is based on the probing of microwave loss near superconducting transition of the bridge. The heat applied to the bridge is generated by the probing signal at the frequency of the high-Q resonator. Since the real part is dominating in the nonlinear impedance of the bridge, the applied heat provides merely amplitude modulation of Q suggesting the suppression of phase jitter of the resonator. The bridge was made from a 50-nm-thick hafnium film (TC≈ 380 mK) sized to 2.5 μm × 2.5 μm. The resonator and the rest of the circuit were made from 200-nm-thick film of niobium (TC≈ 9 K) demonstrating the loaded Q-factor up to and above 10 000 at 1.5 GHz. A cryogenic semiconductor amplifier was used in the readout circuit. The thermal conductance was measured using the steady Q regime of the resonator and found to follow T5down to and below G ≈ 1×10-13W/K. The NEP below 10-18W/√Hz is estimated for the electron temperature of the bridge about 300 mK.

IEEE Transactions on Applied Superconductivity•Apr 17, 2018•4 citations
We propose a new detection technique based on radio-frequency (RF) bias and readout of an antenna-coupled superconducting nanobolometer. This approach is suitable for Frequency-Division-Multiplexing (FDM) readout of large arrays using broadband low-noise RF amplifier. We call this new detector RFTES. This feasibility study was made on demonstrator devices which are made in all-Nb technology and operate at 4.2 K. The studied RFTES devices consist of an antenna-coupled superconducting nanobolometer made of ultrathin niobium films with transition temperature Tc = 5.2 K. The 0.65-THz antenna and nanobolometer are embedded as a load into a GHz-range coplanar niobium resonator (Tc = 8.9 K, Q = 4000). To heat the superconducting Nb nanobolometer close to the Tc, the RF power at resonator frequency f = 5.8 GHz is applied via a transmission line which is weakly coupled (-11 dB) to the loaded resonator. The THz-antenna of RFTES was placed in the focus of a sapphire immersion lens inside a He4-cryostat equipped with an optical window and a semiconductor RF amplifier. We have demonstrated optical response of the RFTES to THz radiation. The demonstrator receiver system employing the RFTES device showed an optical Noise-Equivalent Power (NEP) 1e-14 W/sqrt(Hz) at 4.2 K.
We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a 1.0 × 0.5 μm2 micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ≈3 × 10−12 W/Hz1/2, which is close to expectations for this particular device in the noise-response regime.
To improve both scalability and noise-filtering capability of a transition-edge sensor (TES), a new concept of a thin-film detector is suggested, which is based on embedding a microbridge TES into a high-Q planar GHz-range resonator weakly coupled to a 50-Ω-readout transmission line. Such a TES element is designed as a hot-electron microbolometer coupled to a THz-range antenna and as a load of the resonator at the same time. A weak THz signal coupled to the antenna heats the microbridge TES, thus reducing the quality factor of the resonator and leading to a power increment in the readout line. The power-to-power conversion gain, an essential figure of merit, is estimated to be above 10. To demonstrate the basic concept, we fabricated and tested a few submicrometer-sized devices from Nb thin films for operation temperature about 5 K. The dc and RF characterization of the new device is made at a resonator frequency about 5.8 GHz. A low-noise high-electron mobility transistor amplifier is used in our TES experiments without the need for a SQUID readout. The optical sensitivity to blackbody radiation within the frequency band 600-700 GHz ismeasured as (2.7 ± 0.9) × 10-14W/√Hz at Tc≈ 5 K at bath temperature ≈1.5 K.
We present results of first experiments with elementary cells for detection of sub-millimeter-wave radiation. The cells realize frequency-division multiplexing (FDM) readout of an antenna coupled superconducting hot electron bolometers (HEB) by means of integrated GHz-range superconducting resonators. Such cells can be coupled to a single transmission line for FDM readout, forming a large format imaging metasurface. The design of metasurface, consisting of hexagonal clusters, is discussed and experimental results for both the single cell and the 7-element hexagonal cluster are presented. The prototypes have been fabricated using thin film Nb technology with TCof HEB bridges about 5 K and frequencies of resonators in 5-8 GHz range. Optical sensitivity measurements using a black body radiation source resulted in optical NEP of the cell about 3×10-14W/√Hz at ambient temperature 1.4 K.
Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.
Terahertz (THz) direct detectors based on superconducting niobium nitride hot electron bolometers with thermal, microwave and THz biasing methods have been studied at a frequency of 0.65 THz and at an operating temperature of 4.2 K. A low noise amplifier at room temperature is used to read out the current change of the detectors modulated by the chopping frequency at 732 Hz. The noise spectral density, current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the microwave and THz biasing methods have about one order higher current responsivity than that of the thermal one. With the microwave biasing, an optical NEP at the order of pW/√Hz which shows no deterioration is obtained by choosing the microwave frequency and power appropriately.
We describe the first phase of experimental study of the superconducting bridge RFTES detector at temperatures 20-300 mK including the measurement of its thermal conductance, which fits the model of electron gas heating. We discuss the idea of the RFTES scheme, which is based on the probing of microwave loss near superconducting transition of the bridge. The heat applied to the bridge is generated by the probing signal at the frequency of the high-Q resonator. Since the real part is dominating in the nonlinear impedance of the bridge, the applied heat provides merely amplitude modulation of Q suggesting the suppression of phase jitter of the resonator. The bridge was made from a 50-nm-thick hafnium film (TC≈ 380 mK) sized to 2.5 μm × 2.5 μm. The resonator and the rest of the circuit were made from 200-nm-thick film of niobium (TC≈ 9 K) demonstrating the loaded Q-factor up to and above 10 000 at 1.5 GHz. A cryogenic semiconductor amplifier was used in the readout circuit. The thermal conductance was measured using the steady Q regime of the resonator and found to follow T5down to and below G ≈ 1×10-13W/K. The NEP below 10-18W/√Hz is estimated for the electron temperature of the bridge about 300 mK.