Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1410.5314

Al/AlO$_{\rm {x}}$/Al-Josephson-junction-based microwave generators for weak-signal applications below 100 mK

Behdad Jalali‐Jafari, S. V. Lotkhov, Alexander B Zorin

Published Oct 20, 2014• 3 citations
arXivHTMLPDF

Abstract

An application-specific Josephson generator is being developed as an on-chip calibration source for single-microwave-photon detectors operating below $T \sim $100 mK in the frequency range from 110 to 170 GHz. The targeted calibration power corresponds to the photon detection rate of 0.01 to 10 counts per second. We analyze the Josephson oscillations within the framework of the tunnel junction microscopic (TJM) model and find the corrections to be made to a standard RSJ model of the junction, operating as a quasi-monochromatic source of microwaves. Experimentally, we implemented a number of aluminium-based two-junction interferometers connected to the leads via microstripline resistors made of partly oxidized titanium films. The $I$-$V$ curves exhibit a behaviour ensuring generation of the microwave signal in the frequency range required. By setting the biasing point $\bar{V}$ and applying the magnetic field, one can tune the generator's frequency and power, respectively. A small oscillation linewidth, down to a few GHz, and a low level of black-body radiation emitted by hot parts of the circuit are predicted, using the experimental parameters.

DOI
10.48550/arxiv.1410.5314

Related papers

Detection of On-Chip Generated Weak Microwave Radiation Using Superconducting Normal-Metal SET

Behdad Jalali‐Jafari, S. V. Lotkhov, Alexander B Zorin

The present work addresses quantum interaction phenomena of microwave radiation with a single-electron tunneling system. For this study, an integrated circuit is implemented, combining on the same chip a Josephson junction (Al/AlO x /Al) oscillator and a single-electron transistor (SET) with the superconducting island (Al) and normal-conducting leads (AuPd). The transistor is demonstrated to operate as a very sensitive photon detector, sensing down to a few tens of photons per second in the microwave frequency range around f ∼ 100 GHz. On the other hand, the Josephson oscillator, realized as a two-junction SQUID and coupled to the detector via a coplanar transmission line (Al), is shown to provide a tunable source of microwave radiation: controllable variations in power or in frequency were accompanied by significant changes in the detector output, when applying magnetic flux or adjusting the voltage across the SQUID, respectively. It was also shown that the effect of substrate-mediated phonons, generated by our microwave source, on the detector output was negligibly small.

Applied Sciences•Jan 27, 2016•8 citations

Experimental demonstrations of Josephson threshold detectors for broadband microwave photons detection

J. X. He, P. H. Ouyang, Y. Q. Chai +3 more

In this Letter, we experimentally demonstrated that Josephson threshold detectors (JTDs) could be developed to implement the sensitive detection of broadband microwave photons. Beginning with the numerical simulations of the damped dynamics for the macroscopic phase particle generated by a Josephson junction (JJ), we showed that the time-domain threshold voltage state switched measurements of the JJ driven by a low-frequency triangular wave current, which could be utilized to implement the sensitive microwave photons detection. The detectable signal power can be determined by using the Kumar–Caroll index to quantify the distinguishability between two statistical distributions on the measured threshold switched durations of the JJ with and without the signal input. Experimentally, we fabricated the Al/AlOx/Al JJ and measured its threshold responses, at 50 mK temperature, to the input microwave photons at the frequency of ∼5 GHz. The experimental results indicated that the weak microwave signals, which are phenomenologically threatened by the additional thermal noise that modifies the damped phase dynamics of the JJ, can be detected by the fabricated JTD. The detectable power of the microwave signals demonstrated here was calibrated as about −92 dBm (corresponding to the photons rate of ∼2×108 photons/ms). Based on the numerical simulations for optimizing the relevant performance indicators of the detectors, we further argue that the JTDs could be utilized to achieve the sensitive detection of broadband microwave photons at the single-photon level.

arXiv:2502.14300•Applied Physics Letters•May 19, 2025•6 citations

Development of a Josephson junction based single photon microwave detector for axion detection experiments

D Alesini, D Babusci, C. Barone +30 more

Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.

arXiv:2107.01118•Journal of Physics Conference Series•Jun 1, 2020•13 citations

Josephson Junctions as Narrow-Linewidth Tunable Microwave Oscillators

O. A. Levring, Matteo Cirillo, Bjørn Dueholm +6 more

Extensive measurements of radiation emitted from long Josephson junctions d.c.-current biased on zero-field and Fiske-steps are reported. The measurements were made in the band 8-10 GHz on long Nb-Nb oxide-Pb overlap tunnel junctions with the lengths 0.5 mm and 1.0 mm having fundamental frequencies of 10 GHz and 5 GHz, respectively. Depending on the fundamental frequency of the junction 1st or 2nd harmonic detection was employed. In the fundamental scheme the frequency f n vs. the d.c.-voltage V n along the steps follows a modified Josephson voltage/frequency relation f n / V n = 2 e/nh , where n is the step-number n = 1, 2, 3,... for Fiske-steps and n = 2, 4, 6,... for zero-field steps. On a given step the frequency could be tuned (200-500 MHz) by varying the bias point. The linewidth was measured to be less than 5 kHz. All the observed phenomena are consistent with a novel unified dynamic bunched fluxon model applicable to both zero-field and Fiske-steps and are in good agreement with recent numerical solutions of the perturbed sine-Gordon equation with proper boundary conditions. Taking advantage of operation on higher order steps and strong harmonic generation the present upper frequency limit for the Josephson fluxon oscillator is above 200 GHz. The maximum power observed so far is only 5 pW, but the estimated available power is of the order 1 μW, which is quite sufficient to pump other Josephson devices.

Physica Scripta•Jun 1, 1982•5 citations

DC-operated Josephson junction arrays as a cryogenic on-chip microwave measurement platform

Senne Vervoort, Lukas Nulens, Davi A. D. Chaves +8 more

Abstract Providing radio frequency (RF) signals to cryogenic circuits requires bulky and expensive cabling interfacing specialized RF electronics at room temperature. Superconducting-normal metal-superconducting Josephson junction arrays (JJAs) can change this paradigm by placing the RF source and detector on-chip. In this work, we demonstrate that DC-biased JJAs can emit signals in the C-band frequency spectrum and beyond, with a minimal linewidth of 106.5 ± 0.1 MHz and maximum power of 11.9 fW. We fabricate JJAs comprised of amorphous MoGe or NbTiN superconducting islands and metallic Au weak links. Temperature, magnetic field, applied current, and device design are explored to control the RF sources, while we identify important features that affect the ideal source behavior. Combined with the ability of these JJAs to detect microwave radiation, these sources allow us to propose a fully DC-operated cryogenic on-chip measurement platform that is an alternative to the high-frequency circuitry currently required for quantum applications.

arXiv:2412.17576•Communications Physics•Jul 12, 2025•4 citations

Interactions in small systems of coupled Josephson junctions at microwave frequencies

Thomas F. Finnegan, J. Wilson, J. Toots

A major factor in the practical utilization of any Josephson device for microwave and higher frequency applications (such as the generation and detection of electromagnetic radiation) is the success with which the junction device can be coupled to an external transmission line. As part of an experimental investigation of the electrodynamics of small arrays of Josephson tunnel junctions, the properties of the coherent radiation emitted both by individual junctions and by coupled junction systems have been studied at frequencies between 2 and 12 GHz. Near 9 GHz, more than 10-9 W of coherent radiation has been detected from a single Pb-Pb oxide-Pb junction coupled via waveguide. The development of thin film devices in which the tunnel junctions form part of a microstrip line have made it feasible to observe directly (in a single device) the radiation emitted both at the fundamental geometrical frequency and at the low order harmonics. The observed temperature dependence of the junction cavity Q indicate the low temperature losses are primarily due to cavity loading of the external transmission line.

Revue de Physique Appliquée•Jan 1, 1974•14 citations
Al/AlOx_{\rm {x}}x​/Al-Josephson-junction-based microwave generators for weak-signal applications below 100 mK
An application-specific Josephson generator is being developed as an on-chip calibration source for single-microwave-photon detectors operating below T∼T \sim T∼100 mK in the frequency range from 110 to 170 GHz. The targeted calibration power corresponds to the photon detection rate of 0.01 to 10 counts per second. We analyze the Josephson oscillations within the framework of the tunnel junction microscopic (TJM) model and find the corrections to be made to a standard RSJ model of the junction, operating as a quasi-monochromatic source of microwaves. Experimentally, we implemented a number of aluminium-based two-junction interferometers connected to the leads via microstripline resistors made of partly oxidized titanium films. The III-VVV curves exhibit a behaviour ensuring generation of the microwave signal in the frequency range required. By setting the biasing point Vˉ\bar{V}Vˉ and applying the magnetic field, one can tune the generator's frequency and power, respectively. A small oscillation linewidth, down to a few GHz, and a low level of black-body radiation emitted by hot parts of the circuit are predicted, using the experimental parameters.
The present work addresses quantum interaction phenomena of microwave radiation with a single-electron tunneling system. For this study, an integrated circuit is implemented, combining on the same chip a Josephson junction (Al/AlO x /Al) oscillator and a single-electron transistor (SET) with the superconducting island (Al) and normal-conducting leads (AuPd). The transistor is demonstrated to operate as a very sensitive photon detector, sensing down to a few tens of photons per second in the microwave frequency range around f ∼ 100 GHz. On the other hand, the Josephson oscillator, realized as a two-junction SQUID and coupled to the detector via a coplanar transmission line (Al), is shown to provide a tunable source of microwave radiation: controllable variations in power or in frequency were accompanied by significant changes in the detector output, when applying magnetic flux or adjusting the voltage across the SQUID, respectively. It was also shown that the effect of substrate-mediated phonons, generated by our microwave source, on the detector output was negligibly small.
In this Letter, we experimentally demonstrated that Josephson threshold detectors (JTDs) could be developed to implement the sensitive detection of broadband microwave photons. Beginning with the numerical simulations of the damped dynamics for the macroscopic phase particle generated by a Josephson junction (JJ), we showed that the time-domain threshold voltage state switched measurements of the JJ driven by a low-frequency triangular wave current, which could be utilized to implement the sensitive microwave photons detection. The detectable signal power can be determined by using the Kumar–Caroll index to quantify the distinguishability between two statistical distributions on the measured threshold switched durations of the JJ with and without the signal input. Experimentally, we fabricated the Al/AlOx/Al JJ and measured its threshold responses, at 50 mK temperature, to the input microwave photons at the frequency of ∼5 GHz. The experimental results indicated that the weak microwave signals, which are phenomenologically threatened by the additional thermal noise that modifies the damped phase dynamics of the JJ, can be detected by the fabricated JTD. The detectable power of the microwave signals demonstrated here was calibrated as about −92 dBm (corresponding to the photons rate of ∼2×108 photons/ms). Based on the numerical simulations for optimizing the relevant performance indicators of the detectors, we further argue that the JTDs could be utilized to achieve the sensitive detection of broadband microwave photons at the single-photon level.
Abstract Josephson junctions, in appropriate configurations, can be excellent candidates for detection of single photons in the microwave frequency band. Such possibility has been recently addressed in the framework of galactic axion detection. Here are reported recent developments in the modelling and simulation of dynamic behaviour of a Josephson junction single microwave photon detector. For a Josephson junction to be enough sensitive, small critical currents and operating temperatures of the order of ten of mK are necessary. Thermal and quantum tunnelling out of the zero-voltage state can also mask the detection process. Axion detection would require dark count rates in the order of 0.001 Hz. It is, therefore, is of paramount importance to identify proper device fabrication parameters and junction operation point.
Extensive measurements of radiation emitted from long Josephson junctions d.c.-current biased on zero-field and Fiske-steps are reported. The measurements were made in the band 8-10 GHz on long Nb-Nb oxide-Pb overlap tunnel junctions with the lengths 0.5 mm and 1.0 mm having fundamental frequencies of 10 GHz and 5 GHz, respectively. Depending on the fundamental frequency of the junction 1st or 2nd harmonic detection was employed. In the fundamental scheme the frequency f n vs. the d.c.-voltage V n along the steps follows a modified Josephson voltage/frequency relation f n / V n = 2 e/nh , where n is the step-number n = 1, 2, 3,... for Fiske-steps and n = 2, 4, 6,... for zero-field steps. On a given step the frequency could be tuned (200-500 MHz) by varying the bias point. The linewidth was measured to be less than 5 kHz. All the observed phenomena are consistent with a novel unified dynamic bunched fluxon model applicable to both zero-field and Fiske-steps and are in good agreement with recent numerical solutions of the perturbed sine-Gordon equation with proper boundary conditions. Taking advantage of operation on higher order steps and strong harmonic generation the present upper frequency limit for the Josephson fluxon oscillator is above 200 GHz. The maximum power observed so far is only 5 pW, but the estimated available power is of the order 1 μW, which is quite sufficient to pump other Josephson devices.
Abstract Providing radio frequency (RF) signals to cryogenic circuits requires bulky and expensive cabling interfacing specialized RF electronics at room temperature. Superconducting-normal metal-superconducting Josephson junction arrays (JJAs) can change this paradigm by placing the RF source and detector on-chip. In this work, we demonstrate that DC-biased JJAs can emit signals in the C-band frequency spectrum and beyond, with a minimal linewidth of 106.5 ± 0.1 MHz and maximum power of 11.9 fW. We fabricate JJAs comprised of amorphous MoGe or NbTiN superconducting islands and metallic Au weak links. Temperature, magnetic field, applied current, and device design are explored to control the RF sources, while we identify important features that affect the ideal source behavior. Combined with the ability of these JJAs to detect microwave radiation, these sources allow us to propose a fully DC-operated cryogenic on-chip measurement platform that is an alternative to the high-frequency circuitry currently required for quantum applications.
A major factor in the practical utilization of any Josephson device for microwave and higher frequency applications (such as the generation and detection of electromagnetic radiation) is the success with which the junction device can be coupled to an external transmission line. As part of an experimental investigation of the electrodynamics of small arrays of Josephson tunnel junctions, the properties of the coherent radiation emitted both by individual junctions and by coupled junction systems have been studied at frequencies between 2 and 12 GHz. Near 9 GHz, more than 10-9 W of coherent radiation has been detected from a single Pb-Pb oxide-Pb junction coupled via waveguide. The development of thin film devices in which the tunnel junctions form part of a microstrip line have made it feasible to observe directly (in a single device) the radiation emitted both at the fundamental geometrical frequency and at the low order harmonics. The observed temperature dependence of the junction cavity Q indicate the low temperature losses are primarily due to cavity loading of the external transmission line.