Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1407.4013

A modified Michelson interferometer type Raman laser system for atom interferometers

Ningfang Song, Xiangxiang Lu, Wei Li, Yang Li, Wang, Yingying, Jixun Liu, Xiaobin Xu, Xiong Pan

Published Jul 15, 2014• 0 citations
arXivHTMLPDF

Abstract

We have developed a modified Michelson interferometer type Raman laser system to manipulate cold 87 Rb atoms to interfere. A frequency modulated continuous wave technique was introduced to determine the optical path difference, thus compensating it to zero to minimize the effects of common mode noise. The linewidth (full width at half maximum) of the beat signal at 6.834 GHz was measured to 1Hz limited by the resolution bandwidth of the spectral analyzer. The measured rms phase variance of the phase noise at 166 MHz was 0.015 rad2, mainly restricted by our poor performance radio frequency microwave source. With modest improvements, we plan to apply this laser system to form an atom interferometer for acceleration and rotation measurements.

DOI
10.48550/arxiv.1407.4013

Related papers

Laser-optical system of atomic interferometer based on cold rubidium atoms.

G. V. Osipenko, M. S. Aleynikov, Ju. V. Pashkova +1 more

The paper presents the results of the development of a laser-optical system for atomic interferometer based on rubidium atoms cooled to sub-Doppler temperatures. The laser-optical scheme was created to ensure the processes of cooling, pumping, and detecting atoms involved in interferometric measurements of free-fall acceleration. The system utilizes frequency doubled fiber lasers and broadband fiber electro-optical modulators. The choice of fiber lasers is driven by their high efficiency, narrow spectral line, low phase noise levels, as well as ease of operation and reliability. Laser frequency stabilization was carried out using modulation transfer spectroscopy and optical phase-locking methods. Experimental setups were described that allow the generation of multichromatic radiation and minimize spontaneous scattering by detuning from excited levels. It was noted that the design provides a full set of optical frequencies necessary for Raman spectroscopy. The amplitudes of frequency fluctuations of the cooling and pumping lasers were studied. It was shown that the implemented laser-optical system can ensure continuous operation of an atomic interferometer based on clouds of cold rubidium atoms, and an assessment of the fundamental sensitivity limit was conducted.

Izmeritel`naya Tekhnika•Apr 3, 2025•0 citations

Phase stabilization of laser beams in a cold atom accelerometer

Nicole Byrne

A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.

•Jan 1, 2014•0 citations

Measuring the phase noise of Raman lasers with an atom-based method

Yaning Wang, Shuhua Yan, Dongyang Xu +9 more

Phase noise of Raman lasers is a major source of noise for a Raman-type cold atom interferometer, which is traditionally measured using the signal source analyzer. We report here an atom-based method to measure the phase noise performance between two Raman lasers. By analyzing and calibrating the system noise sources, we can characterize the contribution of phase noise from the total deviation of the relative atom population at the middle of the interference fringe. Knowing the transfer function specified by the operation sequence of the interferometer, we can obtain the transfer function and power spectrum density of the phase noise term. By varying the time sequences of the interferometer, we can measure the white phase noise floor and the phase noise performance over a large range of Fourier frequencies from 1 to 100 000 Hz with a minor difference of 1 dB compared with results from the traditional method using a signal analyzer, which proves the validity of the atom-based method. Compared with the traditional measurement method, the atom-based method can have higher accuracy and have the ability of self-calibrating.

Review of Scientific Instruments•Mar 1, 2021•4 citations

Fast phase stabilization of a low frequency beat note for atom interferometry

E. Oh, R. A. Horne, Charles A. Sackett

Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 μs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the (87)Rb recoil frequency.

Review of Scientific Instruments•Jun 1, 2016•5 citations

A microwave control system for continuous spatial-domain atom interferometers

Weichen Jia, Peiqiang Yan, Yanying Feng

We present a low-phase-noise microwave control system designed for spatial-domain atom interferometers, featuring the independent outputs of three microwave channels with minimal relative phase noise between them. Utilizing a nonlinear transmission line and single-sideband mixing with a digital signal source, we achieved three channels of 6835 MHz microwave frequency outputs, exhibiting absolute phase noises of −55, −100, and −124 dBc/Hz at 1 Hz, 1 kHz, and 1 MHz frequency offsets, respectively. We measured the relative phase noise between channels for a root mean square value of ∼251 μrad. A servo loop was integrated to stabilize the power ratio between Raman laser frequency components, ensuring long-term elimination of light shifts in the atom interferometer. The waveform parameters of the three microwave outputs can be adjusted independently, allowing for flexible manipulation of the atomic interference phase. These capabilities make the proposed microwave control system highly suitable for precise frequency and phase modulation in atom interferometer-based gyroscopes and accelerometers operating within continuous spatial-domain configurations.

AIP Advances•Mar 1, 2025•1 citation

Phase locking technology for Raman laser system based on 1560 nm external cavity lasers

Kainan Wang, Bing Cheng, Yin Zhou +8 more

The technology of generating Raman laser is not only an important research content in the field of quantum precision measurement, but also a core technology of quantum inertial sensors such as cold atom gravimeter, gyroscope. For 87Rb atoms, two 780-nm lasers with a frequency difference of 6.834 GHz and a stable phase are needed to generate Raman light. Raman lasers can be generated by optical phase-locked loops of two 780-nm narrow linewidth external cavity tunable semiconductor lasers (ECDL). But the system thus developed is complicated in structure and very poor in environmental adaptability. The other method to generate Raman laser is based on intracavity 1560-nm laser with frequency doubling and electro-optic modulation technology. This system is simple in structure and strong in environmental adaptability, but it will introduce sideband effects and cannot achieve phase lock due to the limit by the linewidth and feedback bandwidth performance of the laser. In view of this, based on two new 1560-nm external cavity lasers and a home-made phase-locked circuit, in this paper the phase lock of the laser is achieved, and a Raman laser with low phase noise is obtained. The phase noise of beat note signal is as low as –95 dBc/Hz at the Fourier frequency in a range from 1 kHz to 10 kHz. A comparison of this system with the phase-locked performance of the 780-nm dual laser and the hybrid dual laser shows that this scheme has a slight advantage. In addition, the effect of the phase-locking performance on the phase noise of the cold atom interferometer through the method of piecewise integration is analyzed in this work. The experimental results given in this work provide a scheme for developing a miniaturized Raman optical system suitable for external fields.

Acta Physica Sinica•Jan 1, 2021•1 citation
We have developed a modified Michelson interferometer type Raman laser system to manipulate cold 87 Rb atoms to interfere. A frequency modulated continuous wave technique was introduced to determine the optical path difference, thus compensating it to zero to minimize the effects of common mode noise. The linewidth (full width at half maximum) of the beat signal at 6.834 GHz was measured to 1Hz limited by the resolution bandwidth of the spectral analyzer. The measured rms phase variance of the phase noise at 166 MHz was 0.015 rad2, mainly restricted by our poor performance radio frequency microwave source. With modest improvements, we plan to apply this laser system to form an atom interferometer for acceleration and rotation measurements.
The paper presents the results of the development of a laser-optical system for atomic interferometer based on rubidium atoms cooled to sub-Doppler temperatures. The laser-optical scheme was created to ensure the processes of cooling, pumping, and detecting atoms involved in interferometric measurements of free-fall acceleration. The system utilizes frequency doubled fiber lasers and broadband fiber electro-optical modulators. The choice of fiber lasers is driven by their high efficiency, narrow spectral line, low phase noise levels, as well as ease of operation and reliability. Laser frequency stabilization was carried out using modulation transfer spectroscopy and optical phase-locking methods. Experimental setups were described that allow the generation of multichromatic radiation and minimize spontaneous scattering by detuning from excited levels. It was noted that the design provides a full set of optical frequencies necessary for Raman spectroscopy. The amplitudes of frequency fluctuations of the cooling and pumping lasers were studied. It was shown that the implemented laser-optical system can ensure continuous operation of an atomic interferometer based on clouds of cold rubidium atoms, and an assessment of the fundamental sensitivity limit was conducted.
A cold atom accelerometer measures the displacement of a proof mass of laser cooled atoms with respect to an instrument reference frame. The cold atom interferometer's reference frame is defined by a pair of specially prepared, counter-propagating laser beams, that measure inertially induced atom displacements with nm scale resolution. This corresponds to acceleration sensitivities comparable to state of the art electro-mechanical accelerometers. In dynamic environments, sensitivity is limited by the stability of the relative laser phase of the two interrogation laser beams, which is adversely affected by vibrations and temperature fluctuations of the interrogation beam optics. Without an independent measurement, the cold atom interferometer cannot distinguish platform acceleration from laser phase fluctuations, which thus are a potentially serious source of error. In this thesis, a Michelson optical interferometer and an optical feedback loop were used to stabilize the relative phase of the interrogation laser beams in a cold atom accelerometer. A digital controller stabilized the relative phase via an electro-optic phase modulator. This control loop's bandwidth encompasses 98.8% of the noise power as determined from the power spectral density of the open loop 795nm Michelson signal. Increasing the controller bandwidth would gain the system marginal improvement in noise reduction. At an atom interferometer dwell time of 1 msec, active laser phase stabilization improved the atom interferometer sensitivity; at an atom interferometer dwell time of 8msec, an improvement was no longer evident. Improvements to the laser phase stabilization system are proposed to increase atom interferometer stability at longer dwell times.
Phase noise of Raman lasers is a major source of noise for a Raman-type cold atom interferometer, which is traditionally measured using the signal source analyzer. We report here an atom-based method to measure the phase noise performance between two Raman lasers. By analyzing and calibrating the system noise sources, we can characterize the contribution of phase noise from the total deviation of the relative atom population at the middle of the interference fringe. Knowing the transfer function specified by the operation sequence of the interferometer, we can obtain the transfer function and power spectrum density of the phase noise term. By varying the time sequences of the interferometer, we can measure the white phase noise floor and the phase noise performance over a large range of Fourier frequencies from 1 to 100 000 Hz with a minor difference of 1 dB compared with results from the traditional method using a signal analyzer, which proves the validity of the atom-based method. Compared with the traditional measurement method, the atom-based method can have higher accuracy and have the ability of self-calibrating.
Atom interferometry experiments rely on the ability to obtain a stable signal that corresponds to an atomic phase. For interferometers that use laser beams to manipulate the atoms, noise in the lasers can lead to errors in the atomic measurement. In particular, it is often necessary to actively stabilize the optical phase between two frequency components of the beams. Typically this is achieved using a time-domain measurement of a beat note between the two frequencies. This becomes challenging when the frequency difference is small and the phase measurement must be made quickly. The method presented here instead uses a spatial interference detection to rapidly measure the optical phase for arbitrary frequency differences. A feedback system operating at a bandwidth of about 10 MHz could then correct the phase in about 3 μs. This time is short enough that the phase correction could be applied at the start of a laser pulse without appreciably degrading the fidelity of the atom interferometer operation. The phase stabilization system was demonstrated in a simple atom interferometer measurement of the (87)Rb recoil frequency.
We present a low-phase-noise microwave control system designed for spatial-domain atom interferometers, featuring the independent outputs of three microwave channels with minimal relative phase noise between them. Utilizing a nonlinear transmission line and single-sideband mixing with a digital signal source, we achieved three channels of 6835 MHz microwave frequency outputs, exhibiting absolute phase noises of −55, −100, and −124 dBc/Hz at 1 Hz, 1 kHz, and 1 MHz frequency offsets, respectively. We measured the relative phase noise between channels for a root mean square value of ∼251 μrad. A servo loop was integrated to stabilize the power ratio between Raman laser frequency components, ensuring long-term elimination of light shifts in the atom interferometer. The waveform parameters of the three microwave outputs can be adjusted independently, allowing for flexible manipulation of the atomic interference phase. These capabilities make the proposed microwave control system highly suitable for precise frequency and phase modulation in atom interferometer-based gyroscopes and accelerometers operating within continuous spatial-domain configurations.
The technology of generating Raman laser is not only an important research content in the field of quantum precision measurement, but also a core technology of quantum inertial sensors such as cold atom gravimeter, gyroscope. For 87Rb atoms, two 780-nm lasers with a frequency difference of 6.834 GHz and a stable phase are needed to generate Raman light. Raman lasers can be generated by optical phase-locked loops of two 780-nm narrow linewidth external cavity tunable semiconductor lasers (ECDL). But the system thus developed is complicated in structure and very poor in environmental adaptability. The other method to generate Raman laser is based on intracavity 1560-nm laser with frequency doubling and electro-optic modulation technology. This system is simple in structure and strong in environmental adaptability, but it will introduce sideband effects and cannot achieve phase lock due to the limit by the linewidth and feedback bandwidth performance of the laser. In view of this, based on two new 1560-nm external cavity lasers and a home-made phase-locked circuit, in this paper the phase lock of the laser is achieved, and a Raman laser with low phase noise is obtained. The phase noise of beat note signal is as low as –95 dBc/Hz at the Fourier frequency in a range from 1 kHz to 10 kHz. A comparison of this system with the phase-locked performance of the 780-nm dual laser and the hybrid dual laser shows that this scheme has a slight advantage. In addition, the effect of the phase-locking performance on the phase noise of the cold atom interferometer through the method of piecewise integration is analyzed in this work. The experimental results given in this work provide a scheme for developing a miniaturized Raman optical system suitable for external fields.