Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1406.3274 · Physical Review A

Optimal quantum-enhanced interferometry

Matthias D. Lang, Carlton M. Caves

Published Aug 25, 2014• 89 citations
arXivHTMLPDF

Abstract

We analyze the ultimate bounds on the phase sensitivity of an interferometer, given the constraint that the state input to the interferometer's initial 50:50 beam splitter $B$ is a product state of the two input modes. Requiring a product state is a natural restriction: If one were allowed to input an arbitrary, entangled two-mode state $|\ensuremath{\Xi}\ensuremath{\rangle}$ to the beam splitter, one could generally just as easily input the state $B|\ensuremath{\Xi}\ensuremath{\rangle}$ directly into the two modes after the beam splitter, thus rendering the beam splitter unnecessary. We find optimal states for a fixed photon number and for a fixed mean photon number.

DOI
10.1103/physreva.90.025802

Related papers

Criticality in two-mode interferometers

Hongbin Liang, Yuguo Su, Xiao Xiao +3 more

To achieve the optimal phase sensitivity in two-mode interferometers, one key problem is how to distribute photons between the two input ports, given a fixed total average photon number. In both the $\text{SU}(2)$ and $\text{SU}(1,1)$ interferometers with a product of coherent and Fock states as inputs, we find there exists a critical value of the total photon number, below which the optimal phase sensitivity can be achieved with the second port being the vacuum state. The critical points can be analytically fixed. We further consider a more general input state as a product of coherent and squeezed Fock states. Then we analytically identify three regions in the parameter space, similar to a phase diagram, and find that critical phenomena occur in two regions. If the total average input photon number is less than the critical value, the optimal distribution tends to minimize the average photon number in the second port. Our finding indicates that, in order to get interferometers with high sensitivity, one must carefully choose the photon number distribution according to the value of the input total average photon number. This central result will be useful in theoretical studies in the field of quantum parameter estimation.

Physical Review A•Jul 22, 2020•6 citations

Optimal Quantum-Enhanced Interferometry Using a Laser Power Source

Matthias D. Lang, Carlton M. Caves

We consider an interferometer powered by laser light (a coherent state) into one input port and ask the following question: what is the best state to inject into the second input port, given a constraint on the mean number of photons this state can carry, in order to optimize the interferometer's phase sensitivity? This question is the practical question for high-sensitivity interferometry. We answer the question by considering the quantum Cramér-Rao bound for such a setup. The answer is squeezed vacuum.

arXiv:1306.2677•Physical Review Letters•Oct 22, 2013•188 citations

Optimal entangled coherent states in lossy quantum-enhanced metrology

Su‐Yong Lee, Yong Sup Ihn, Zaeill Kim

We investigate an optimal distance of two components in an entangled coherent state for quantum phase estimation in lossy interferometry. The optimal distance is obtained by an economical point, representing the quantum Fisher information that we can extract per input energy. Maximizing the formula of the quantum Fisher information over an input mean photon number, we show that, as the losses of the interferometer increase, it can be more beneficial to prepare an initially entangled coherent state that is less entangled. This represents that the optimal distance of the two-mode components decreases with more loss in the interferometry. Under the constraint of the input mean photon number, we obtain that the optimal entangled coherent state is more robust than a separable coherent state, even in a high photon loss rate. The optimal entangled coherent state preserves quantum advantage over the standard interferometric limit of the separable coherent state. We also show that the corresponding optimal measurement requires correlation measurement bases.

arXiv:1906.05402•Physical Review A•Jan 21, 2020•23 citations

Measures of Nonclassical Correlations and Quantum-Enhanced Interferometry

Matthias Lang

In the first part of this dissertation a framework for categorizing entropic measures of nonclassical correlations in bipartite quantum states is presented. The measures are based on the difference between a quantum entropic quantity and the corresponding classical quantity obtained from measurements on the two systems. Three types of entropic quantities are used, and three different measurement strategies are applied to these quantities. Many of the resulting measures of nonclassical correlations have been proposed previously. Properties of the various measures are explored, and results of evaluating the measures for two-qubit quantum states are presented. To demonstrate how these measures differ from entanglement we move to the set of Bell-diagonal states for two qubits, which can be depicted as a tetrahedron in three dimensions. We consider the level surfaces of entanglement and of the correlation measures from our framework for Bell-diagonal states. This provides a complete picture of the structure of entanglement and discord for this simple case and, in particular, of their nonanalytic behavior under decoherence. The pictorial approach also indicates how to show that all of the proposed correlation measures are neither convex nor concave. In the second part we look at two practical interferometric setups that use nonclassical states of light to enhance their performance. First we consider an interferometer powered by laser light (a coherent state) into one input port and ask the following question: what is the best state to inject into the second input port, given a constraint on the mean number of photons this state can carry, in order to optimize the interferometer's phase sensitivity? This question is the practical question for high-sensitivity interferometry. We answer the question by considering the quantum Cram\'er-Rao bound for such a setup. The answer is squeezed vacuum. Then we analyze the ultimate bounds on the phase sensitivity of an interferometer, given the constraint that the state input to the interferometer's initial 50:50 beam splitter B is a product state of the two input modes. Requiring a product state is a natural restriction: if one were allowed to input an arbitrary, entangled two-mode state $|\Xi \rangle$ to the beam splitter, one could generally just as easily input the state $B|\Xi \rangle$ directly into the two modes after the beam splitter, thus rendering the beam splitter unnecessary. We find optimal states for a fixed photon number and for a fixed mean photon number. Our results indicate that entanglement is not a crucial resource for quantum-enhanced interferometry. Initially the analysis for both of these setups is performed for the idealized case of a lossless interferometer. Then the analysis is extended to the more realistic scenario where the interferometer suffers from photon losses.

•Jan 1, 2015•0 citations

Adaptive quantum estimation of phase shifts

Daniela Denot, Thorsten C. Bschorr, Matthias Freyberger

We discuss an adaptive interferometric approach to quantum estimation of phase shifts. In a first step we find optimized two-mode input states for a generalized Mach-Zehnder interferometer. These two states show a small phase variance at the so-called Heisenberg limit. It turns out that they can be generated by entangling a coherent state and a squeezed vacuum at a beam splitter. Moreover, the interferometric setup allows us to describe an adaptive estimation scheme for arbitrary phase shifts if we assume a fixed mean photon number as a quantum resource.

Physical Review A•Jan 30, 2006•8 citations

Quantum limit of precision for phase estimation in squeezing-enhanced interferometry with a single-mode readout

Dmitri B. Horoshko, Fedor Jelezko

We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We find the ultimate limit of precision for such an interferometer by calculating the quantum Fisher information of the mixed quantum state in one of the interferometer's outputs about the difference phase. We show that, in the vicinity of the black fringe, this information is asymptotically close to the quantum Fisher information about this phase for the two-mode readout. We conclude that the single-mode readout is optimal for phase estimation in squeezing-enhanced interferometry and allows for the Heisenberg scaling of precision. We also show that the optimal local measurement in the vicinity of the black fringe consists of amplifying the output field in a phase-sensitive way and measuring its photon number.

quant-pharXiv:2603.07556•Mar 10, 2026•1 citation
We analyze the ultimate bounds on the phase sensitivity of an interferometer, given the constraint that the state input to the interferometer's initial 50:50 beam splitter BBB is a product state of the two input modes. Requiring a product state is a natural restriction: If one were allowed to input an arbitrary, entangled two-mode state ∣\ensuremathΞ\ensuremath⟩|\ensuremath{\Xi}\ensuremath{\rangle}∣\ensuremathΞ\ensuremath⟩ to the beam splitter, one could generally just as easily input the state B∣\ensuremathΞ\ensuremath⟩B|\ensuremath{\Xi}\ensuremath{\rangle}B∣\ensuremathΞ\ensuremath⟩ directly into the two modes after the beam splitter, thus rendering the beam splitter unnecessary. We find optimal states for a fixed photon number and for a fixed mean photon number.
To achieve the optimal phase sensitivity in two-mode interferometers, one key problem is how to distribute photons between the two input ports, given a fixed total average photon number. In both the SU(2)\text{SU}(2)SU(2) and SU(1,1)\text{SU}(1,1)SU(1,1) interferometers with a product of coherent and Fock states as inputs, we find there exists a critical value of the total photon number, below which the optimal phase sensitivity can be achieved with the second port being the vacuum state. The critical points can be analytically fixed. We further consider a more general input state as a product of coherent and squeezed Fock states. Then we analytically identify three regions in the parameter space, similar to a phase diagram, and find that critical phenomena occur in two regions. If the total average input photon number is less than the critical value, the optimal distribution tends to minimize the average photon number in the second port. Our finding indicates that, in order to get interferometers with high sensitivity, one must carefully choose the photon number distribution according to the value of the input total average photon number. This central result will be useful in theoretical studies in the field of quantum parameter estimation.
We consider an interferometer powered by laser light (a coherent state) into one input port and ask the following question: what is the best state to inject into the second input port, given a constraint on the mean number of photons this state can carry, in order to optimize the interferometer's phase sensitivity? This question is the practical question for high-sensitivity interferometry. We answer the question by considering the quantum Cramér-Rao bound for such a setup. The answer is squeezed vacuum.
We investigate an optimal distance of two components in an entangled coherent state for quantum phase estimation in lossy interferometry. The optimal distance is obtained by an economical point, representing the quantum Fisher information that we can extract per input energy. Maximizing the formula of the quantum Fisher information over an input mean photon number, we show that, as the losses of the interferometer increase, it can be more beneficial to prepare an initially entangled coherent state that is less entangled. This represents that the optimal distance of the two-mode components decreases with more loss in the interferometry. Under the constraint of the input mean photon number, we obtain that the optimal entangled coherent state is more robust than a separable coherent state, even in a high photon loss rate. The optimal entangled coherent state preserves quantum advantage over the standard interferometric limit of the separable coherent state. We also show that the corresponding optimal measurement requires correlation measurement bases.
In the first part of this dissertation a framework for categorizing entropic measures of nonclassical correlations in bipartite quantum states is presented. The measures are based on the difference between a quantum entropic quantity and the corresponding classical quantity obtained from measurements on the two systems. Three types of entropic quantities are used, and three different measurement strategies are applied to these quantities. Many of the resulting measures of nonclassical correlations have been proposed previously. Properties of the various measures are explored, and results of evaluating the measures for two-qubit quantum states are presented. To demonstrate how these measures differ from entanglement we move to the set of Bell-diagonal states for two qubits, which can be depicted as a tetrahedron in three dimensions. We consider the level surfaces of entanglement and of the correlation measures from our framework for Bell-diagonal states. This provides a complete picture of the structure of entanglement and discord for this simple case and, in particular, of their nonanalytic behavior under decoherence. The pictorial approach also indicates how to show that all of the proposed correlation measures are neither convex nor concave. In the second part we look at two practical interferometric setups that use nonclassical states of light to enhance their performance. First we consider an interferometer powered by laser light (a coherent state) into one input port and ask the following question: what is the best state to inject into the second input port, given a constraint on the mean number of photons this state can carry, in order to optimize the interferometer's phase sensitivity? This question is the practical question for high-sensitivity interferometry. We answer the question by considering the quantum Cram\'er-Rao bound for such a setup. The answer is squeezed vacuum. Then we analyze the ultimate bounds on the phase sensitivity of an interferometer, given the constraint that the state input to the interferometer's initial 50:50 beam splitter B is a product state of the two input modes. Requiring a product state is a natural restriction: if one were allowed to input an arbitrary, entangled two-mode state ∣Ξ⟩|\Xi \rangle∣Ξ⟩ to the beam splitter, one could generally just as easily input the state B∣Ξ⟩B|\Xi \rangleB∣Ξ⟩ directly into the two modes after the beam splitter, thus rendering the beam splitter unnecessary. We find optimal states for a fixed photon number and for a fixed mean photon number. Our results indicate that entanglement is not a crucial resource for quantum-enhanced interferometry. Initially the analysis for both of these setups is performed for the idealized case of a lossless interferometer. Then the analysis is extended to the more realistic scenario where the interferometer suffers from photon losses.
We discuss an adaptive interferometric approach to quantum estimation of phase shifts. In a first step we find optimized two-mode input states for a generalized Mach-Zehnder interferometer. These two states show a small phase variance at the so-called Heisenberg limit. It turns out that they can be generated by entangling a coherent state and a squeezed vacuum at a beam splitter. Moreover, the interferometric setup allows us to describe an adaptive estimation scheme for arbitrary phase shifts if we assume a fixed mean photon number as a quantum resource.
We consider an optical interferometer with coherent light in one input and a squeezed vacuum in another. Such an interferometer is known to beat the standard quantum limit of sensitivity to the difference of phase shifts in its arms. We find the ultimate limit of precision for such an interferometer by calculating the quantum Fisher information of the mixed quantum state in one of the interferometer's outputs about the difference phase. We show that, in the vicinity of the black fringe, this information is asymptotically close to the quantum Fisher information about this phase for the two-mode readout. We conclude that the single-mode readout is optimal for phase estimation in squeezing-enhanced interferometry and allows for the Heisenberg scaling of precision. We also show that the optimal local measurement in the vicinity of the black fringe consists of amplifying the output field in a phase-sensitive way and measuring its photon number.