Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1405.5837 · Physical Review B

Isotopic identification of engineered nitrogen-vacancy spin qubits in ultrapure diamond

Takashi Yamamoto, Shinobu Onoda, Takeshi Ohshima, Tokuyuki Teraji, Kenji Watanabe, Satoshi Koizumi, Takahide Umeda, Liam Paul McGuinness, Christoph Müller, Boris Naydenov, Florian Dolde, Helmut Fedder, Jan Honert, Matthew Markham, Daniel J. Twitchen, Jörg Wrachtrup, Fedor Jelezko, Junichi Isoya

Published Aug 29, 2014• 16 citations
arXivHTMLPDF

Abstract

Nitrogen impurities help to stabilize the negatively-charged-state of ${\mathrm{NV}}^{\ensuremath{-}}$ in diamond, whereas magnetic fluctuations from nitrogen spins lead to decoherence of ${\mathrm{NV}}^{\ensuremath{-}}$ qubits. It is not known what donor concentration optimizes these conflicting requirements. Here we used 10-MeV ${}^{15}{\mathrm{N}}^{3+}$ ion implantation to create ${\mathrm{NV}}^{\ensuremath{-}}$ in ultrapure diamond. Optically detected magnetic resonance of single centers revealed a high creation yield of $40\ifmmode\pm\else\textpm\fi{}3%$ from ${}^{15}{\mathrm{N}}^{3+}$ ions and an additional yield of $56\ifmmode\pm\else\textpm\fi{}3%$ from $^{14}\mathrm{N}$ impurities. High-temperature anneal was used to reduce residual defects, and charge stable ${\mathrm{NV}}^{\ensuremath{-}}$, even in a dilute $^{14}\mathrm{N}$ impurity concentration of 0.06 ppb were created with long coherence times.

DOI
10.1103/physrevb.90.081117

Related papers

Extending spin coherence times of diamond qubits by high-temperature annealing

Takashi Yamamoto, Takahide Umeda, Kenji Watanabe +14 more

Spins of negatively charged nitrogen-vacancy (NV${}^{\ensuremath{-}}$) defects in diamond are among the most promising candidates for solid-state qubits. The fabrication of quantum devices containing these spin-carrying defects requires position-controlled introduction of NV${}^{\ensuremath{-}}$ defects having excellent properties such as spectral stability, a long spin coherence time, and a stable negative charge state. Nitrogen ion implantation and annealing enable the positioning of NV${}^{\ensuremath{-}}$ spin qubits with high precision, but to date, the coherence times of qubits produced this way are short, presumably because of the presence of residual radiation damage. In the present work, we demonstrate that a high-temperature annealing at 1000 ${}^{\ensuremath{\circ}}$C allows 2 ms coherence times to be achieved at room temperature. These results were obtained for implantation-produced NV${}^{\ensuremath{-}}$ defects in a high-purity, 99.99% ${}^{12}$C-enriched single crystal chemical vapor deposited diamond. We discuss these long coherence times in the context of the thermal behavior of residual defect spins.

arXiv:1309.4316•Physical Review B•Aug 23, 2013•179 citations

Characterization and optimization of NV centers in CVD diamond for sensing applications

Tingpeng Luo, Lukas Lindner, Julia Langer +13 more

The negatively charged nitrogen-vacancy (NV-) center in diamond is a promising spin system for quantum sensing applications. NV-ensembles are favored for an improved signal-to-noise ratio and sensitivity. The optimization of diamond with NV-ensembles often requires a high NV concentration, a long spin coherence time T2 and a stable charge state. However, these key requirements are interdependent and can be difficult to optimize: nitrogen impurities as the main decoherence source of the NV spin limits the coherence time T2, and pursuing high NV concentration can deteriorate the NV-charge-state stability. Consequently, their best achievable combination becomes an essential question for the material characterization. In this work, we systematically investigate the NV center creation and properties in chemical vapor deposition (CVD) diamond. We have grown CVD diamond series with a varying nitrogen flow over four orders of magnitude, leading to a broad range of single substitutional nitrogen (P1 center) densities from 0.2 to 20 ppm. On these series, we study P1, NV creations and NV charge states after growth, as well as their transformation under subsequent electron beam irradiation. Furthermore, for a fixed nitrogen concentration, we optimize electron-irradiation fluences with two different accelerated electron energies. We discuss a general approach to determine the optimal irradiation conditions, for which an enhanced NV concentration and an optimum of NV charge states can both be satisfied. Moreover, through irradiation and annealing treatments, we monitor the change in T2 and aim to increase the NV density without compromising T2. We achieve NV concentrations from 1 to 168 ppb with T2 from 549 to 45.5 µs respectively. This study shows a pathway to engineer properties of NV-doped CVD diamonds for improved sensitivity.

•Jun 8, 2022•0 citations

Ten-Second Electron-Spin Coherence in Isotopically Engineered Diamond

Takashi Yamamoto, H. Benjamin van Ommen, Kai-Niklas Schymik +7 more

Solid-state spin defects are a promising platform for quantum networks. A key requirement is to combine long ground-state spin-coherence times with a coherent optical transition for spin-photon entanglement. Here, we investigate the spin and optical coherence of single nitrogen-vacancy (NV) centres in (111)-grown isotopically engineered diamond. Our diamond-growth process yields a precisely controlled $^{13}\mathrm{C}$ concentration and low-ppb nitrogen concentrations. Combined with the mitigation of 50 Hz noise using a real-time feedforward scheme and tailored decoupling sequences, this enables record defect-electron-spin coherence times of $T_2 = 6.8(1)$ ms for a Hahn echo and of $T_2^{DD} = 11.2(8)$ s under dynamical decoupling. In addition, we observe coherent optical transitions with a near-lifetime-limited homogeneous linewidth of 16.9(4) MHz and characterize the spectral diffusion dynamics. These results provide new avenues to investigate the incorporation of impurities in diamond and new opportunities for improved spin-qubit control for quantum networks and other quantum technologies.

quant-pharXiv:2604.07439•npj Quantum Information•Apr 10, 2026•8 citations

Doping optimization of charge state stability for shallow nitrogen-vacancy center ensembles in HPHT diamonds

Qin Wu, Die Fang, Yu Ma +9 more

Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.

Applied Physics Letters•Jun 16, 2025•1 citation

Nitrogen ion implantation for controlled nitrogen-vacancy center creation in single- and polycrystalline diamond

Zeeshan Rashid, Nemanja Markešević, S. Lagomarsino +11 more

Precise control over the spatial distribution and charge state of nitrogen-vacancy (NV) centers in diamond is a key requirement for further advancing this platform in quantum sensing and photonic applications. Here, we investigate nitrogen ion implantation as a scalable method to engineer NV centers in bulk single-crystalline (SC) and a 5 μ m -thick polycrystalline (PC) diamond membrane. Nitrogen-doped regions (1–80 ppm) were fabricated using a 0.7 MeV ion beam and high-temperature annealing, with NV center formation verified by confocal fluorescence imaging and spectral analysis. In SC bulk diamond, we estimate the NV concentration from spectral analysis and model the fluorescence response as a function of implantation dose, capturing both the initial increase at low concentrations and a saturation behavior at higher doses due to quenching mechanisms. In contrast, PC diamond membranes show a weaker dependence at low implantation fluences, consistent with pre-existing nitrogen impurities, thus making a statistical model significantly more complex. The activation yield is found to be of order of 1%, which is lower than in N-rich diamond samples, as implanted N is predominantly interstitial. Photoluminescence spectroscopy indicates that NV 0 is the dominant charge state in both materials, with a laser-power-dependent redistribution between neutral and negative charge states. Optically detected magnetic resonance (ODMR) measurements in SC bulk diamond resolve the hyperfine structure and allow extraction of the dephasing time ( T 2 ∗ ), while in PC diamond membranes, where NV centers tend do form near the grain boundaries, the ODMR signals are observed but spectral resolution is currently limited by impurities, grain-dependent NV orientations, and photoluminescence background.

Diamond and Related Materials•Sep 12, 2026•0 citations

Generation and Characterization of NV Quantum Registers Using Isotopically Enriched Molecular Ions

Onoda Shinobu, Kimura Kosuke, Oguro Tsubasa +5 more

A nitrogen vacancy (NV) center in diamond is known as a solid-state spin quantum bit (qubit) at room temperature. The fabrication of scalable quantum registers based on NV centers is a long-standing issue. In 2005, spin-spin interaction between NV-N pairs, which were fabricated by N2 ion implantation, was reported. An entanglement between two electron-spin qubits becomes an excellent quantum information processing component, as accomplished by an NV-NV pair with a nanometer-scale distance in 2010 and 2013. More recently,strongly dipolar coupled NV-NV pairs were realized by 14N 30 keV implantationvia nanoholes in PMMA resist mask. The creation yields of NV-NV pairs dramatically improved, and the nanohole implantation had been thought to be the most promising technique to integrate NV centers. However, the problem of the technique is the finite size of nanoholes. The distribution of nitrogen atoms is determined by both ion straggling and nanohole diameter. The scaling of NV centers is stagnant up to two for several years. To overcome the barrier of triple NV centers, our previous research gave a ground-breaking idea of a highly populated NV center complex by introducing a molecular ion implantation technique in 2019. Since the molecular ion is regarded as an idea point source, the distribution of nitrogen atoms is determined by only ion straggling. Therefore, our proposed method is more effective than other implantation techniques including nanohole implantation. Instead of a pure nitrogen cluster which is commonly unstable, the stable organic molecular ions (adenine; C5N5H5) were utilized as the ion source. We successfully implanted C5N4Hn ions into single crystalline diamonds. Three NV centers were integrated, and the dipolar interactions among them were successfully observed. In 2022, we succeeded in creating more than 5 NV centers by phthalocyanine (C32H18N8) ion implantation. The next challenge is the implantation of isotopically enriched molecular ions. The isotopically enriched ion contains 13C and 15N. The implantation of isotopically enriched molecular ions is able to create 15NV-13C hybrid quantum registers. In this presentation, we will show the development of the isotopically enriched molecular ion beam and the characterization of created NV centers by laboratory-built confocal microscopy (CFM) and optically detected magnetic resonance (ODMR).

•Jul 7, 2025•0 citations
Nitrogen impurities help to stabilize the negatively-charged-state of NV\ensuremath−{\mathrm{NV}}^{\ensuremath{-}}NV\ensuremath− in diamond, whereas magnetic fluctuations from nitrogen spins lead to decoherence of NV\ensuremath−{\mathrm{NV}}^{\ensuremath{-}}NV\ensuremath− qubits. It is not known what donor concentration optimizes these conflicting requirements. Here we used 10-MeV 15N3+{}^{15}{\mathrm{N}}^{3+}15N3+ ion implantation to create NV\ensuremath−{\mathrm{NV}}^{\ensuremath{-}}NV\ensuremath− in ultrapure diamond. Optically detected magnetic resonance of single centers revealed a high creation yield of 40\ifmmode±\else\textpm\fi340\ifmmode\pm\else\textpm\fi{}3%40\ifmmode±\else\textpm\fi3 from 15N3+{}^{15}{\mathrm{N}}^{3+}15N3+ ions and an additional yield of 56\ifmmode±\else\textpm\fi356\ifmmode\pm\else\textpm\fi{}3%56\ifmmode±\else\textpm\fi3 from 14N^{14}\mathrm{N}14N impurities. High-temperature anneal was used to reduce residual defects, and charge stable NV\ensuremath−{\mathrm{NV}}^{\ensuremath{-}}NV\ensuremath−, even in a dilute 14N^{14}\mathrm{N}14N impurity concentration of 0.06 ppb were created with long coherence times.
Spins of negatively charged nitrogen-vacancy (NV${}^{\ensuremath{-}}$) defects in diamond are among the most promising candidates for solid-state qubits. The fabrication of quantum devices containing these spin-carrying defects requires position-controlled introduction of NV${}^{\ensuremath{-}}$ defects having excellent properties such as spectral stability, a long spin coherence time, and a stable negative charge state. Nitrogen ion implantation and annealing enable the positioning of NV${}^{\ensuremath{-}}$ spin qubits with high precision, but to date, the coherence times of qubits produced this way are short, presumably because of the presence of residual radiation damage. In the present work, we demonstrate that a high-temperature annealing at 1000 ${}^{\ensuremath{\circ}}$C allows 2 ms coherence times to be achieved at room temperature. These results were obtained for implantation-produced NV${}^{\ensuremath{-}}$ defects in a high-purity, 99.99% 12{}^{12}12C-enriched single crystal chemical vapor deposited diamond. We discuss these long coherence times in the context of the thermal behavior of residual defect spins.
The negatively charged nitrogen-vacancy (NV-) center in diamond is a promising spin system for quantum sensing applications. NV-ensembles are favored for an improved signal-to-noise ratio and sensitivity. The optimization of diamond with NV-ensembles often requires a high NV concentration, a long spin coherence time T2 and a stable charge state. However, these key requirements are interdependent and can be difficult to optimize: nitrogen impurities as the main decoherence source of the NV spin limits the coherence time T2, and pursuing high NV concentration can deteriorate the NV-charge-state stability. Consequently, their best achievable combination becomes an essential question for the material characterization. In this work, we systematically investigate the NV center creation and properties in chemical vapor deposition (CVD) diamond. We have grown CVD diamond series with a varying nitrogen flow over four orders of magnitude, leading to a broad range of single substitutional nitrogen (P1 center) densities from 0.2 to 20 ppm. On these series, we study P1, NV creations and NV charge states after growth, as well as their transformation under subsequent electron beam irradiation. Furthermore, for a fixed nitrogen concentration, we optimize electron-irradiation fluences with two different accelerated electron energies. We discuss a general approach to determine the optimal irradiation conditions, for which an enhanced NV concentration and an optimum of NV charge states can both be satisfied. Moreover, through irradiation and annealing treatments, we monitor the change in T2 and aim to increase the NV density without compromising T2. We achieve NV concentrations from 1 to 168 ppb with T2 from 549 to 45.5 µs respectively. This study shows a pathway to engineer properties of NV-doped CVD diamonds for improved sensitivity.
Solid-state spin defects are a promising platform for quantum networks. A key requirement is to combine long ground-state spin-coherence times with a coherent optical transition for spin-photon entanglement. Here, we investigate the spin and optical coherence of single nitrogen-vacancy (NV) centres in (111)-grown isotopically engineered diamond. Our diamond-growth process yields a precisely controlled 13C^{13}\mathrm{C}13C concentration and low-ppb nitrogen concentrations. Combined with the mitigation of 50 Hz noise using a real-time feedforward scheme and tailored decoupling sequences, this enables record defect-electron-spin coherence times of T2=6.8(1)T_2 = 6.8(1)T2​=6.8(1) ms for a Hahn echo and of T2DD=11.2(8)T_2^{DD} = 11.2(8)T2DD​=11.2(8) s under dynamical decoupling. In addition, we observe coherent optical transitions with a near-lifetime-limited homogeneous linewidth of 16.9(4) MHz and characterize the spectral diffusion dynamics. These results provide new avenues to investigate the incorporation of impurities in diamond and new opportunities for improved spin-qubit control for quantum networks and other quantum technologies.
Since nitrogen-vacancy (NV) centers in diamond have emerged as crucial quantum sensors in physics and biology, the massive preparation of high-quality and high-concentration shallow NV center samples has become urgent and demanding. As NV centers approach the surface and their concentration increases, charge state instability can degrade coherence and introduce additional noise. This problem is further complicated in high-pressure and high-temperature (HPHT) diamonds due to the presence of unclear impurities and inhomogeneous strain. Through optically detected magnetic resonance testing on various implanted samples, we analyzed the spin and charge state properties of shallow NV center ensembles. Our results reveal that the doping dose significantly influences the quantity of NV−, charge, and charge stability. Our findings indicate that over-implanting nitrogen as electron donors before starting graphitization helps stabilize the charge environment of the shallow NV center ensembles. By controlling the nitrogen ion implantation dose, we optimized charge state stability under photoionization and prepared high-quality NV center ensemble samples in HPHT diamonds at the optimal implantation dose range of 2×1013–8×1013 ions/cm2. This method, which relies solely on nitrogen ion implantation and annealing on HPHT diamond, significantly reduces the cost of sensor samples, greatly benefiting the promotion of quantum sensing.
Precise control over the spatial distribution and charge state of nitrogen-vacancy (NV) centers in diamond is a key requirement for further advancing this platform in quantum sensing and photonic applications. Here, we investigate nitrogen ion implantation as a scalable method to engineer NV centers in bulk single-crystalline (SC) and a 5 μ m -thick polycrystalline (PC) diamond membrane. Nitrogen-doped regions (1–80 ppm) were fabricated using a 0.7 MeV ion beam and high-temperature annealing, with NV center formation verified by confocal fluorescence imaging and spectral analysis. In SC bulk diamond, we estimate the NV concentration from spectral analysis and model the fluorescence response as a function of implantation dose, capturing both the initial increase at low concentrations and a saturation behavior at higher doses due to quenching mechanisms. In contrast, PC diamond membranes show a weaker dependence at low implantation fluences, consistent with pre-existing nitrogen impurities, thus making a statistical model significantly more complex. The activation yield is found to be of order of 1%, which is lower than in N-rich diamond samples, as implanted N is predominantly interstitial. Photoluminescence spectroscopy indicates that NV 0 is the dominant charge state in both materials, with a laser-power-dependent redistribution between neutral and negative charge states. Optically detected magnetic resonance (ODMR) measurements in SC bulk diamond resolve the hyperfine structure and allow extraction of the dephasing time ( T 2 ∗ ), while in PC diamond membranes, where NV centers tend do form near the grain boundaries, the ODMR signals are observed but spectral resolution is currently limited by impurities, grain-dependent NV orientations, and photoluminescence background.
A nitrogen vacancy (NV) center in diamond is known as a solid-state spin quantum bit (qubit) at room temperature. The fabrication of scalable quantum registers based on NV centers is a long-standing issue. In 2005, spin-spin interaction between NV-N pairs, which were fabricated by N2 ion implantation, was reported. An entanglement between two electron-spin qubits becomes an excellent quantum information processing component, as accomplished by an NV-NV pair with a nanometer-scale distance in 2010 and 2013. More recently,strongly dipolar coupled NV-NV pairs were realized by 14N 30 keV implantationvia nanoholes in PMMA resist mask. The creation yields of NV-NV pairs dramatically improved, and the nanohole implantation had been thought to be the most promising technique to integrate NV centers. However, the problem of the technique is the finite size of nanoholes. The distribution of nitrogen atoms is determined by both ion straggling and nanohole diameter. The scaling of NV centers is stagnant up to two for several years. To overcome the barrier of triple NV centers, our previous research gave a ground-breaking idea of a highly populated NV center complex by introducing a molecular ion implantation technique in 2019. Since the molecular ion is regarded as an idea point source, the distribution of nitrogen atoms is determined by only ion straggling. Therefore, our proposed method is more effective than other implantation techniques including nanohole implantation. Instead of a pure nitrogen cluster which is commonly unstable, the stable organic molecular ions (adenine; C5N5H5) were utilized as the ion source. We successfully implanted C5N4Hn ions into single crystalline diamonds. Three NV centers were integrated, and the dipolar interactions among them were successfully observed. In 2022, we succeeded in creating more than 5 NV centers by phthalocyanine (C32H18N8) ion implantation. The next challenge is the implantation of isotopically enriched molecular ions. The isotopically enriched ion contains 13C and 15N. The implantation of isotopically enriched molecular ions is able to create 15NV-13C hybrid quantum registers. In this presentation, we will show the development of the isotopically enriched molecular ion beam and the characterization of created NV centers by laboratory-built confocal microscopy (CFM) and optically detected magnetic resonance (ODMR).