Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1404.3133 · Physical Review A

Utilizing nitrogen-vacancy centers to measure oscillating magnetic fields

Adam Zaman Chaudhry

Published Oct 7, 2014• 20 citations
arXivHTMLPDF

Abstract

We show how nitrogen-vacancy centers can be used to determine the amplitude, phase, and frequency of unknown weak monochromatic and multichromatic oscillating magnetic fields using only the periodic dynamical decoupling and Carr-Purcell-Meiboom-Gill sequences. The effect of decoherence on the measurement of the magnetic field parameters is explicitly analyzed, and we take into account the fact that different pulse sequences suppress decoherence to different extents. Since the sensitivity increases with increasing sensing time while it decreases due to decoherence and limited photon detection efficiency, we use the Fisher information matrix in order to optimize the number of pulses that should be used.

DOI
10.1103/physreva.90.042104

Related papers

Detecting the presence of weak magnetic fields using nitrogen-vacancy centers

Adam Zaman Chaudhry

We show how nitrogen-vacancy centers can be used to detect the presence of weak magnetic fields, that is, to find out whether a magnetic field, about which we may not have complete information, is actually present or not. The solution to this problem comes from quantum state discrimination theory. The effect of decoherence is taken into account to optimize the time over which the nitrogen-vacancy center is allowed to interact with the magnetic field before making a measurement. We also find the optimum measurement that should be performed. We then show how multiple measurements reduce the error in detecting the magnetic field. Finally, a major limitation of the measurement process, namely, limited photon detection efficiency, is taken into account. Our proposals should be implementable with current experimental technology.

arXiv:1412.0389•Physical Review A•Jun 11, 2015•15 citations

Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures

Demitry Farfurnik, A Jarmola, D Budker +1 more

Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.

arXiv:1709.03368•Journal of Optics•Dec 14, 2017•15 citations

Ambiguous resonances in multipulse quantum sensing with nitrogen-vacancy centers

Lucas Tsunaki, Anmol Singh, Kseniia Volkova +4 more

Dynamical decoupling multipulse sequences can be applied to solid-state spins for sensing weak oscillating fields from nearby single nuclear spins. By periodically reversing the probing system's evolution, other noises are counteracted and filtered out over the total evolution. However, the technique is subject to intricate interactions resulting in additional resonant responses, which can be misinterpreted with the actual signal intended to be measured. We experimentally characterize three of these effects present in single nitrogen-vacancy centers in diamond, where we also develop a numerical simulation model without rotating-wave approximation, showing robust correlation to the experimental data. Regarding centers with the N 15 nitrogen isotope, we observe that a small misalignment in the bias magnetic field causes the precession of the nitrogen nuclear spin to be sensed by the electronic spin of the center. Another studied case of ambiguous resonances comes from the coupling with lattice C 13 nuclei, where we use the echo modulation frequencies to obtain the interaction Hamiltonian and then utilize the latter to simulate multipulse sequences. Finally, we also measure and simulate the effects from the free evolution of the quantum system during finite pulse durations. Due to the large data volume and the strong dependence of these ambiguous resonances with specific experimental parameters, we provide a simulations data set with a user-friendly graphical interface, where users can compare simulations with their own experimental data for spectral disambiguation. Although focused on nitrogen-vacancy centers and dynamical decoupling sequences, these results and the developed model can potentially be applied to other solid-state spins and quantum sensing techniques.

arXiv:2407.09411•Physical Review A•Feb 7, 2025•12 citations

Detection of weak magnetic fields using nitrogen-vacancy centers with maximum confidence

Ghazi Khan, Adam Zaman Chaudhry

The problem of detection of magnetic fields using NV centers, that is, to check whether a weak magnetic field is present or not, can be tackled using quantum state discrimination theory. In this regard, we find the POVMs that maximize the confidence of any given measurement, taking the interaction time as well as decoherence into account. We apply our formalism over a wide range of scenarios encompassing constant and oscillating magnetic fields, while also using techniques such as dynamical decoupling to improve the confidence and extending our treatment to ensembles of NV centers.

arXiv:2112.04856•Dec 9, 2021•0 citations

Comparison of dynamical decoupling protocols for a nitrogen-vacancy center in diamond

Zhi‐Hui Wang, G. de Lange, Diego Ristè +2 more

We perform a detailed theoretical-experimental study of the dynamical decoupling (DD) of the nitrogen-vacancy (NV) center in diamond. We investigate the DD sequences applied to suppress the dephasing of the electron spin of the NV center induced by the coupling to a spin bath composed of the substitutional nitrogen atoms. The decoupling efficiency of various DD schemes is studied, including both periodic and aperiodic pulse sequences. For ideal control pulses, we find that the DD protocols with the Carr-Purcell-Meiboom-Gill (CPMG) timing of the pulses provides best performance. We show that, as the number of control pulses increases, the decoupling fidelity scaling differs qualitatively from the predictions of the Magnus expansion, and explain the origin of this difference. In particular, more advanced symmetrized or concatenated protocols do not improve the DD performance. Next, we investigate the impact of the systematic instrumental pulse errors in different periodic and aperiodic pulse sequences. The DD protocols with the single-axis control do not preserve all spin components in the presence of the pulse errors, and the two-axis control is needed. We demonstrate that the two-axis control sequence with the CPMG timing is very robust with respect to the pulse errors. The impact of the pulse errors can be diminished further by symmetrizing this protocol. For all protocols studied here, we present a detailed account of the pulse error parameters which make the strongest impact on the DD performance. In conclusion, we give specific recommendations about choosing the decoupling protocol for the system under investigation.

arXiv:1202.0462•Physical Review B•Apr 11, 2012•131 citations

Sensitive measurement of phase shift of an AC magnetic field by quantum sensing with multiple-pulse decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.

arXiv:1808.03784•Journal of Applied Physics•Aug 12, 2019•2 citations
We show how nitrogen-vacancy centers can be used to determine the amplitude, phase, and frequency of unknown weak monochromatic and multichromatic oscillating magnetic fields using only the periodic dynamical decoupling and Carr-Purcell-Meiboom-Gill sequences. The effect of decoherence on the measurement of the magnetic field parameters is explicitly analyzed, and we take into account the fact that different pulse sequences suppress decoherence to different extents. Since the sensitivity increases with increasing sensing time while it decreases due to decoherence and limited photon detection efficiency, we use the Fisher information matrix in order to optimize the number of pulses that should be used.
We show how nitrogen-vacancy centers can be used to detect the presence of weak magnetic fields, that is, to find out whether a magnetic field, about which we may not have complete information, is actually present or not. The solution to this problem comes from quantum state discrimination theory. The effect of decoherence is taken into account to optimize the time over which the nitrogen-vacancy center is allowed to interact with the magnetic field before making a measurement. We also find the optimum measurement that should be performed. We then show how multiple measurements reduce the error in detecting the magnetic field. Finally, a major limitation of the measurement process, namely, limited photon detection efficiency, is taken into account. Our proposals should be implementable with current experimental technology.
Abstract Ensembles of nitrogen-vacancy centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10–250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure 12 C sample, we find that the Carr-Purcell–Meiboom-Gill protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ( > 500 ) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (∼10 kHz), for which the experiment time approaches T 1 at a small number of applied DD pulses.
Dynamical decoupling multipulse sequences can be applied to solid-state spins for sensing weak oscillating fields from nearby single nuclear spins. By periodically reversing the probing system's evolution, other noises are counteracted and filtered out over the total evolution. However, the technique is subject to intricate interactions resulting in additional resonant responses, which can be misinterpreted with the actual signal intended to be measured. We experimentally characterize three of these effects present in single nitrogen-vacancy centers in diamond, where we also develop a numerical simulation model without rotating-wave approximation, showing robust correlation to the experimental data. Regarding centers with the N 15 nitrogen isotope, we observe that a small misalignment in the bias magnetic field causes the precession of the nitrogen nuclear spin to be sensed by the electronic spin of the center. Another studied case of ambiguous resonances comes from the coupling with lattice C 13 nuclei, where we use the echo modulation frequencies to obtain the interaction Hamiltonian and then utilize the latter to simulate multipulse sequences. Finally, we also measure and simulate the effects from the free evolution of the quantum system during finite pulse durations. Due to the large data volume and the strong dependence of these ambiguous resonances with specific experimental parameters, we provide a simulations data set with a user-friendly graphical interface, where users can compare simulations with their own experimental data for spectral disambiguation. Although focused on nitrogen-vacancy centers and dynamical decoupling sequences, these results and the developed model can potentially be applied to other solid-state spins and quantum sensing techniques.
The problem of detection of magnetic fields using NV centers, that is, to check whether a weak magnetic field is present or not, can be tackled using quantum state discrimination theory. In this regard, we find the POVMs that maximize the confidence of any given measurement, taking the interaction time as well as decoherence into account. We apply our formalism over a wide range of scenarios encompassing constant and oscillating magnetic fields, while also using techniques such as dynamical decoupling to improve the confidence and extending our treatment to ensembles of NV centers.
We perform a detailed theoretical-experimental study of the dynamical decoupling (DD) of the nitrogen-vacancy (NV) center in diamond. We investigate the DD sequences applied to suppress the dephasing of the electron spin of the NV center induced by the coupling to a spin bath composed of the substitutional nitrogen atoms. The decoupling efficiency of various DD schemes is studied, including both periodic and aperiodic pulse sequences. For ideal control pulses, we find that the DD protocols with the Carr-Purcell-Meiboom-Gill (CPMG) timing of the pulses provides best performance. We show that, as the number of control pulses increases, the decoupling fidelity scaling differs qualitatively from the predictions of the Magnus expansion, and explain the origin of this difference. In particular, more advanced symmetrized or concatenated protocols do not improve the DD performance. Next, we investigate the impact of the systematic instrumental pulse errors in different periodic and aperiodic pulse sequences. The DD protocols with the single-axis control do not preserve all spin components in the presence of the pulse errors, and the two-axis control is needed. We demonstrate that the two-axis control sequence with the CPMG timing is very robust with respect to the pulse errors. The impact of the pulse errors can be diminished further by symmetrizing this protocol. For all protocols studied here, we present a detailed account of the pulse error parameters which make the strongest impact on the DD performance. In conclusion, we give specific recommendations about choosing the decoupling protocol for the system under investigation.
Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.