Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1403.6586 · Physical Review B

Microwave nanobolometer based on proximity Josephson junctions

Joonas Govenius, Russell E. Lake, Kuan Yen Tan, Ville Pietilä, J. K. Julin, Ilari J. Maasilta, Pauli Virtanen, Mikko Möttönen

Published Aug 11, 2014• 43 citations
arXivHTMLPDF

Abstract

We introduce a microwave bolometer aimed at high-quantum-efficiency detection of wave packet energy within the framework of circuit quantum electrodynamics, the ultimate goal being single microwave photon detection. We measure the differential thermal conductance between the detector and its heat bath, obtaining values as low as $5\phantom{\rule{4.pt}{0ex}}\text{fW}/\mathrm{K}$ at $50\phantom{\rule{4.pt}{0ex}}\text{mK}$. This is one tenth of the thermal conductance quantum and corresponds to a theoretical lower bound on noise-equivalent power of order ${10}^{\ensuremath{-}20}\phantom{\rule{4.pt}{0ex}}\text{W}/\sqrt{\text{Hz}}$ at $50\phantom{\rule{4.pt}{0ex}}\text{mK}$. By measuring the differential thermal conductance of the same bolometer design in substantially different environments and materials, we determine that electron-photon coupling dominates the thermalization of our nanobolometer.

DOI
10.1103/physrevb.90.064505

Related papers

Bolometric detection of Josephson radiation

Bayan Karimi, Gorm O. Steffensen, Andrew P. Higginbotham +3 more

One of the most promising approaches towards large-scale quantum computation uses devices based on many Josephson junctions. Yet, even today, open questions regarding the single junction remain unsolved, such as the detailed understanding of the quantum phase transitions, the coupling of the Josephson junction to the environment or how to improve the coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir connected to a Josephson junction that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium, that is, biased conditions. The bolometer converts the a.c. Josephson current at microwave frequencies up to about 100 GHz into a temperature rise measured by d.c. thermometry. A circuit model based on realistic parameter values captures both the current-voltage characteristics and the measured power quantitatively. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements.

arXiv:2402.09314•Nature Nanotechnology•Aug 22, 2024•13 citations

Reaching the ultimate energy resolution of a quantum detector

Bayan Karimi, Fredrik Brange, Peter Samuelsson +1 more

Quantum calorimetry, the thermal measurement of quanta, is a method of choice for ultrasensitive radiation detection ranging from microwaves to gamma rays. The fundamental temperature fluctuations of the calorimeter, dictated by the coupling of it to the heat bath, set the ultimate lower bound of its energy resolution. Here we reach this limit of fundamental equilibrium fluctuations of temperature in a nanoscale electron calorimeter, exchanging energy with the phonon bath at very low temperatures. The approach allows noninvasive measurement of energy transport in superconducting quantum circuits in the microwave regime with high efficiency, opening the way, for instance, to observe quantum jumps, detecting their energy to tackle central questions in quantum thermodynamics.

Nature Communications•Jan 17, 2020•90 citations

Mikroaaltopulssien reaaliaikainen havaitseminen heikosti suprajohtavalla bolometrilla

Kohvakka, Kassius

Sensitive and reliable photon detectors are ubiquitous tools in countless fields of engineering and the sciences. One of the most mature and widely applied approaches to photodetection is bolometry, where the absorption of radiation causes a measurable change in the temperature of the absorber material. Applications of bolometry include fields such as astrophysics, medicine, particle physics, and metrology, all of which greatly benefit from the development of more versatile and efficient detectors. In the field of superconducting quantum circuits, considerable progress has recently been made in developing ultrasensitive superconducting bolometers. Operating in the single-photon regime, these devices hold great potential for several applications within quantum technology, including qubit state measurement and characterization of microwave components and cryogenic environments. State-of-the-art bolometers based on graphene have been shown to reach sufficient energy resolution and operation speed to be applicable in the context of circuit quantum electrodynamics. In this thesis, a superconducting bolometer based on superconductor-normal-metal-superconductor Josephson junctions is studied. In particular, a detection protocol based on optimal filtering of the noisy detector output signal is implemented to detect microwave pulses during continuous operation of the device. The fidelity of the implemented real-time detection scheme is experimentally tested and compared to the theoretical energy resolution of the studied bolometer, computed from noise equivalent power. The device is found to reach 50% detection probability with minimal dark-count rate at pulse energies of approximately 2.2 zJ, exceeding the predicted resolution of 0.75 zJ by only a factor of three. In addition, the characteristic energy of the detector is determined to be approximately 1.5 zJ based on the total energy of pulses detected with fidelity F=0.5. The results give hope of future applications of the detection scheme to more sensitive bolometer samples.

•Jan 26, 2021•0 citations

Experimental demonstrations of Josephson threshold detectors for broadband microwave photons detection

J. X. He, P. H. Ouyang, Y. Q. Chai +3 more

In this Letter, we experimentally demonstrated that Josephson threshold detectors (JTDs) could be developed to implement the sensitive detection of broadband microwave photons. Beginning with the numerical simulations of the damped dynamics for the macroscopic phase particle generated by a Josephson junction (JJ), we showed that the time-domain threshold voltage state switched measurements of the JJ driven by a low-frequency triangular wave current, which could be utilized to implement the sensitive microwave photons detection. The detectable signal power can be determined by using the Kumar–Caroll index to quantify the distinguishability between two statistical distributions on the measured threshold switched durations of the JJ with and without the signal input. Experimentally, we fabricated the Al/AlOx/Al JJ and measured its threshold responses, at 50 mK temperature, to the input microwave photons at the frequency of ∼5 GHz. The experimental results indicated that the weak microwave signals, which are phenomenologically threatened by the additional thermal noise that modifies the damped phase dynamics of the JJ, can be detected by the fabricated JTD. The detectable power of the microwave signals demonstrated here was calibrated as about −92 dBm (corresponding to the photons rate of ∼2×108 photons/ms). Based on the numerical simulations for optimizing the relevant performance indicators of the detectors, we further argue that the JTDs could be utilized to achieve the sensitive detection of broadband microwave photons at the single-photon level.

arXiv:2502.14300•Applied Physics Letters•May 19, 2025•6 citations

Detecting Single Photons with Graphene-Based Josephson Junctions

Evan D. Walsh

In this work I present theory, modeling, and experimentation demonstrating that the graphene-based Josephson junction (GJJ) is a capable system for the detection of single photons across the electromagnetic spectrum, from the microwave to the infrared. Two different detection mechanisms are exposed: 1) heating of the graphene weak link in the GJJ and 2) quasiparticle generation in the GJJ superconducting contacts. The first relies on graphene's exceptionally low heat capacity and its decoupled electron and phonon systems. I show in modeling that these thermal properties can lead to a GJJ photon detector for very low energy microwave photons. Experimentally, I show that a GJJ bolometer with its graphene weak link coupled to a microwave resonator can achieve an energy resolution equivalent to a single 32-GHz photon. The second detection mechanism reveals itself in the illumination of a GJJ with near-infrared light. I experimentally demonstrate single-photon detection in this system and show that the data is well fit by a model where photon-induced quasiparticles in the superconducting contacts cause the GJJ phase particle to escape. I give an overview of the single-photon, graphene, and Josephson-junction physics required to arrive at these results before presenting the experimental evidence for single-microwave-photon sensitivity and single-infrared-photon detection with the GJJ.

•Nov 23, 2020•0 citations

Noise Measurements in Hot-Electron Titanium Nanobolometers

Boris S. Karasik, Sergei V. Pereverzev, David I. Olaya +3 more

We are presenting experimental results on the electrical noise in small titanium hot-electron nanobolometers with the critical temperature above 300 mK. The noise data demonstrate good agreement with the conventional bolometer theory prediction. The noise is dominated by the thermal energy fluctuations (phonon noise) when the operating temperature is set just a few mK below the superconducting transition. The corresponding noise equivalent power (NEP) is about 3 times 10-18W/Hz1/2for the smallest measured device. The relative NEP's for the two devices measured scale roughly as the square root of the device volume as one would expect from the theory. Therefore an additional factor of 2-3 reduction of NEP may be feasible if the length and width of our device are further reduced. The demonstrated combination of the low NEP and the relatively high operating temperature is attractive for submillimeter low-background applications.

IEEE Transactions on Applied Superconductivity•Jun 1, 2009•14 citations
We introduce a microwave bolometer aimed at high-quantum-efficiency detection of wave packet energy within the framework of circuit quantum electrodynamics, the ultimate goal being single microwave photon detection. We measure the differential thermal conductance between the detector and its heat bath, obtaining values as low as 5fW/K5\phantom{\rule{4.pt}{0ex}}\text{fW}/\mathrm{K}5fW/K at 50mK50\phantom{\rule{4.pt}{0ex}}\text{mK}50mK. This is one tenth of the thermal conductance quantum and corresponds to a theoretical lower bound on noise-equivalent power of order 10\ensuremath−20W/Hz{10}^{\ensuremath{-}20}\phantom{\rule{4.pt}{0ex}}\text{W}/\sqrt{\text{Hz}}10\ensuremath−20W/Hz​ at 50mK50\phantom{\rule{4.pt}{0ex}}\text{mK}50mK. By measuring the differential thermal conductance of the same bolometer design in substantially different environments and materials, we determine that electron-photon coupling dominates the thermalization of our nanobolometer.
One of the most promising approaches towards large-scale quantum computation uses devices based on many Josephson junctions. Yet, even today, open questions regarding the single junction remain unsolved, such as the detailed understanding of the quantum phase transitions, the coupling of the Josephson junction to the environment or how to improve the coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir connected to a Josephson junction that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium, that is, biased conditions. The bolometer converts the a.c. Josephson current at microwave frequencies up to about 100 GHz into a temperature rise measured by d.c. thermometry. A circuit model based on realistic parameter values captures both the current-voltage characteristics and the measured power quantitatively. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements.
Quantum calorimetry, the thermal measurement of quanta, is a method of choice for ultrasensitive radiation detection ranging from microwaves to gamma rays. The fundamental temperature fluctuations of the calorimeter, dictated by the coupling of it to the heat bath, set the ultimate lower bound of its energy resolution. Here we reach this limit of fundamental equilibrium fluctuations of temperature in a nanoscale electron calorimeter, exchanging energy with the phonon bath at very low temperatures. The approach allows noninvasive measurement of energy transport in superconducting quantum circuits in the microwave regime with high efficiency, opening the way, for instance, to observe quantum jumps, detecting their energy to tackle central questions in quantum thermodynamics.
Sensitive and reliable photon detectors are ubiquitous tools in countless fields of engineering and the sciences. One of the most mature and widely applied approaches to photodetection is bolometry, where the absorption of radiation causes a measurable change in the temperature of the absorber material. Applications of bolometry include fields such as astrophysics, medicine, particle physics, and metrology, all of which greatly benefit from the development of more versatile and efficient detectors. In the field of superconducting quantum circuits, considerable progress has recently been made in developing ultrasensitive superconducting bolometers. Operating in the single-photon regime, these devices hold great potential for several applications within quantum technology, including qubit state measurement and characterization of microwave components and cryogenic environments. State-of-the-art bolometers based on graphene have been shown to reach sufficient energy resolution and operation speed to be applicable in the context of circuit quantum electrodynamics. In this thesis, a superconducting bolometer based on superconductor-normal-metal-superconductor Josephson junctions is studied. In particular, a detection protocol based on optimal filtering of the noisy detector output signal is implemented to detect microwave pulses during continuous operation of the device. The fidelity of the implemented real-time detection scheme is experimentally tested and compared to the theoretical energy resolution of the studied bolometer, computed from noise equivalent power. The device is found to reach 50% detection probability with minimal dark-count rate at pulse energies of approximately 2.2 zJ, exceeding the predicted resolution of 0.75 zJ by only a factor of three. In addition, the characteristic energy of the detector is determined to be approximately 1.5 zJ based on the total energy of pulses detected with fidelity F=0.5. The results give hope of future applications of the detection scheme to more sensitive bolometer samples.
In this Letter, we experimentally demonstrated that Josephson threshold detectors (JTDs) could be developed to implement the sensitive detection of broadband microwave photons. Beginning with the numerical simulations of the damped dynamics for the macroscopic phase particle generated by a Josephson junction (JJ), we showed that the time-domain threshold voltage state switched measurements of the JJ driven by a low-frequency triangular wave current, which could be utilized to implement the sensitive microwave photons detection. The detectable signal power can be determined by using the Kumar–Caroll index to quantify the distinguishability between two statistical distributions on the measured threshold switched durations of the JJ with and without the signal input. Experimentally, we fabricated the Al/AlOx/Al JJ and measured its threshold responses, at 50 mK temperature, to the input microwave photons at the frequency of ∼5 GHz. The experimental results indicated that the weak microwave signals, which are phenomenologically threatened by the additional thermal noise that modifies the damped phase dynamics of the JJ, can be detected by the fabricated JTD. The detectable power of the microwave signals demonstrated here was calibrated as about −92 dBm (corresponding to the photons rate of ∼2×108 photons/ms). Based on the numerical simulations for optimizing the relevant performance indicators of the detectors, we further argue that the JTDs could be utilized to achieve the sensitive detection of broadband microwave photons at the single-photon level.
In this work I present theory, modeling, and experimentation demonstrating that the graphene-based Josephson junction (GJJ) is a capable system for the detection of single photons across the electromagnetic spectrum, from the microwave to the infrared. Two different detection mechanisms are exposed: 1) heating of the graphene weak link in the GJJ and 2) quasiparticle generation in the GJJ superconducting contacts. The first relies on graphene's exceptionally low heat capacity and its decoupled electron and phonon systems. I show in modeling that these thermal properties can lead to a GJJ photon detector for very low energy microwave photons. Experimentally, I show that a GJJ bolometer with its graphene weak link coupled to a microwave resonator can achieve an energy resolution equivalent to a single 32-GHz photon. The second detection mechanism reveals itself in the illumination of a GJJ with near-infrared light. I experimentally demonstrate single-photon detection in this system and show that the data is well fit by a model where photon-induced quasiparticles in the superconducting contacts cause the GJJ phase particle to escape. I give an overview of the single-photon, graphene, and Josephson-junction physics required to arrive at these results before presenting the experimental evidence for single-microwave-photon sensitivity and single-infrared-photon detection with the GJJ.
We are presenting experimental results on the electrical noise in small titanium hot-electron nanobolometers with the critical temperature above 300 mK. The noise data demonstrate good agreement with the conventional bolometer theory prediction. The noise is dominated by the thermal energy fluctuations (phonon noise) when the operating temperature is set just a few mK below the superconducting transition. The corresponding noise equivalent power (NEP) is about 3 times 10-18W/Hz1/2for the smallest measured device. The relative NEP's for the two devices measured scale roughly as the square root of the device volume as one would expect from the theory. Therefore an additional factor of 2-3 reduction of NEP may be feasible if the length and width of our device are further reduced. The demonstrated combination of the low NEP and the relatively high operating temperature is attractive for submillimeter low-background applications.