We used an atom interferometer for atom optical shop testing of lenses for atomic de Broglie waves. We measured focal lengths and spherical aberrations of electrostatic lenses in three independent ways based on contrast data, phase data, or calculations of de Broglie wavefront curvature. We report focal lengths of -2.5 km and -21.7 km with 5% uncertainty for different lenses. All three methods give consistent results. Understanding how lenses magnify and distort atom interference fringes helps improve atom beam velocity measurements made with phase choppers [New J. Phys. 13, 115007 (2011)], which in turn will improve the accuracy of atomic polarizability measurements.
We used an atom interferometer for atom optical shop testing of lenses for atomic de Broglie waves. We measured focal lengths and spherical aberrations of electrostatic lenses in three independent ways based on contrast data, phase data, or calculations of de Broglie wavefront curvature. We report focal lengths of -2.5 km and -21.7 km with 5% uncertainty for different lenses. All three methods give consistent results. Understanding how lenses magnify and distort atom interference fringes helps improve atom beam velocity measurements made with phase choppers [New J. Phys. 13, 115007 (2011)], which in turn will improve the accuracy of atomic polarizability measurements.
To improve precision measurements made with atom interferometers, the effect of de Broglie wave-front curvature induced by a lens inside an atom interferometer is experimentally demonstrated and theoretically analyzed. Electrostatic lenses shift, magnify, and distort atom interference fringes, which modifies the phase and the contrast of the interference signals. Informed by these observations, an improved method is presented for analyzing measurements of atomic beam velocity distributions using phase choppers [W. F. Holmgren, I. Hromada, C. E. Klauss, and A. D. Cronin, New J. Phys. 13, 115007 (2011)].
Atom interferometers, in which de Broglie waves are coherently split and recombined to make interference fringes, now serve as precision measurement tools for several quantities in physics. Examples include measurements of Newton's constant, the fine structure constant, van der Waals potentials, and atomic polarizabilities. To make next-generation measurements of static electric dipole atomic polarizabilities with an atom beam interferometer, I worked on new methods to precisely measure the velocity distribution for atom beams. I will explain how I developed and used phase choppers to measure lithium, sodium, potassium, and cesium atomic beam velocities with 0.07% accuracy. I also present new measurements of polarizability for these atoms. I classify systematic errors into two broad categories: (1) fractional errors that are similar for all different types of atoms in our experiments, and (2), errors that scale with de Broglie wavelength or inverse atomic momentum in our experiments. This distinction is important for estimating the uncertainty in our measurements of ratios of atomic polarizabilities, e.g., αCs / αNₐ = 2.488(12).
Two experiments are presented which measure atomic properties using an atom interferometer. The interferometer splits the sodium de Broglie wave into two paths, one of which travels through an interaction region. The paths are recombined, and the interference pattern exhibits a phase shift depending on the strength of the interaction. In the first experiment, the interaction involves a gas. De Broglie waves traveling through the gas experience a phase shift represented by an index of refraction. By measuring the index of refraction at various wavelengths, the predicted phenomenon of glory oscillations in the phase shift has been observed for the first time. The index of refraction has been measured for sodium atoms in gases of argon, krypton, xenon, and nitrogen over a wide range of wavelength. These measurements offer detailed insight into the interatomic potential between sodium atoms and the gases. Theoretical predictions of the interatomic potentials are challenged by these results, which should encourage a renewed effort to better understand these potentials. The second experiment measures atomic polarizability with an atom interferometer. Here, the interaction is with an electric field; the atom experiences a phase shift proportional to its energy inside the field. Previously, this method was used to perform the most accurate (< 1%) measurement of sodium polarizability. The precision was limited, however, by the spread of velocities in the atomic beam-the phase shift is different depending on velocity, and the -interference pattern is washed out.
We describe a new method to measure atom beam velocity in an atom interferometer using phase choppers. Phase choppers are analogous to mechanical chopping discs, but rather than being transmitted or blocked by mechanical choppers, an atom receives different differential phase shifts (e.g. zero or π radians) from phase choppers. Phase choppers yield 0.1% uncertainty measurements of beam velocity in our interferometer with 20 min of data and enable new measurements of polarizability with unprecedented precision.
We have built an atom interferometer and, by applying an electric field on one of the two interfering beams, we have measured the static electric polarizability of lithium $\ensuremath{\alpha}=(24.33\ifmmode\pm\else\textpm\fi{}0.16)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}30}\phantom{\rule{0.3em}{0ex}}{\mathrm{m}}^{3}$ with a 0.66% uncertainty. Our experiment is similar to an experiment done on sodium in 1995 by Pritchard and co-workers, with several improvements: the electric field can be calculated analytically and the interference signals have a large intensity and a high visibility, resulting in accurate phase measurements. This experiment illustrates the extreme sensitivity of atom interferometry: when the atom enters the electric field, its velocity increases and the fractional change, equal to $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}9}$ for our largest field, is measured with a ${10}^{\ensuremath{-}3}$ accuracy.
I used a Mach-Zehnder atom interferometer to measure the static electric-dipole polarizabilities of K, Rb, and Cs atoms with 0.11\% uncertainty. Static polarizability measurements serve as benchmark tests for 𝑎𝑏 𝑖𝑛𝑖𝑡𝑖𝑜 atomic structure calculations. Calculating atomic properties such as polarizabilities, van der Waals coefficients, state lifetimes, or oscillator strengths involves accurately calculating the valence electrons' electric-dipole transition matrix elements. Additionally, testing Cs atomic structure calculations helps interpret the results of parity non-conservation experiments, which in turn places constraints on beyond-the-standard-model physics. I discuss improvements to our experiment that allowed us to measure static polarizabilities with 0.11% uncertainty, and we present our results in the context of recent 𝑎𝑏 𝑖𝑛𝑖𝑡𝑖𝑜 and semi-empirical static polarizabilities and recent, high-precision measurements of excited state lifetimes and van der Waals C₆ coefficients. I also used our interferometer to develop a new technique for inertial sensing. High precision, portable, atom-interferometer gyroscopes and accelerometers are desirable for self-contained inertial navigation and in the future may be used for tests of General Relativity and searches for gravitational waves using satellite-mounted inertial sensors. Satellite-mounted atom interferometers are challenging to build because of size, weight, power, and reliability constraints. Atom interferometers that use nanogratings to diffract atoms are attractive for satellite-mounted inertial sensing applications because nanogratings weigh approximately nothing and require no power. We developed a new 𝑖𝑛 𝑠𝑖𝑡𝑢 measurement technique using our nanograting atom interferometer, and we used it to measure inertial forces for the benefit of our static polarizability measurements. I also review how to calculate the sensitivity of a nanograting atom interferometer, and I employed these calculations in order to design a portable, nanograting atom interferometer inertial sensor.