Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1309.2814 · Nature

Coherent control of the waveforms of recoilless γ-ray photons

Farit G. Vagizov, V. A. Antonov, Yevgeny V. Radeonychev, R. N. Shakhmuratov, Olga A. Kocharovskaya

Published Mar 16, 2014• 130 citations
arXivHTMLPDF
DOI
10.1038/nature13018

Related papers

Coherent γ-ray optics

J. P. Hannon, G. T. Trammell

Hyperfine Interactions•Mar 1, 1999•117 citations

Gamma-ray emission harnessed for single photon pulses

Physics Today•Mar 18, 2014•0 citations

Ultimate capabilities for compression of the waveform of a recoilless γ-ray photon into a pulse sequence in an optically deep vibrating resonant absorber

I. R. Khairulin, V. A. Antonov, Yevgeny V. Radeonychev +1 more

Recently, an exponentially decaying waveform (the time dependence of detection probability) of a M\"ossbauer \ensuremath{\gamma}-ray photon was transformed into a regular sequence of short pulses in a sinusoidally vibrating recoilless resonant absorber [F. Vagizov, V. Antonov, Y. V. Radeonychev, R. N. Shakhmuratov, and O. Kocharovskaya, Coherent control of the waveforms of recoilless \ensuremath{\gamma}-photons, Nature (London) 508, 80 (2014)]. In the present paper, we show that the peak amplitude of the pulses can be considerably increased via joint adjustment of optical depth of the absorber and the initial phase of its vibration. This is due to reduction of the photoelectric absorption and maximizing the constructive temporal interference of spectral content of the single-photon wave packet in an optically deep absorber. The ultimate capabilities for transforming a waveform of a 14.4-keV photon from a $^{57}\mathrm{Co}$ radioactive source into a regular train of pulses in a harmonically vibrating $^{57}\mathrm{Fe}$ recoilless resonant absorber are discussed. We show that the shortest pulse duration, produced by this technique, is limited by the highest available vibration frequency of a piezoelectric transducer and at present can be as short as 7.7 ps. The maximum achievable detection probability of the transformed photon at the experimentally feasible conditions is more than two times higher than peak detection probability of the photon emitted by the source and nearly 5.5 times higher than obtained in the above reference.

Physical Review A•Oct 31, 2018•14 citations

Transformation of Mössbauer γ -ray photon waveform into short pulses in dual-tone vibrating resonant absorber

I. R. Khairulin, V. A. Antonov, Yevgeny V. Radeonychev +1 more

Abstract The transformation of exponentially decaying waveform (the time dependence of detection probability) of a Mössbauer γ -ray photon into a regular sequence of short nearly bandwidth-limited pulses in a vibrating recoilless resonant absorber is studied. The case of dual-tone vibration at the fundamental frequency and its second harmonic under experimentally feasible conditions is considered. We show that this technique allows one to shorten pulses and increase the ratio of pulse separation to pulse length as well as to enlarge pulse amplitude compared to the pulses produced in harmonically vibrating absorber. The obtained results pave the way to the development of the time-resolved Mössbauer γ -ray spectroscopy and manipulation of quantum information in hard x-ray/ γ -ray range.

Journal of Physics B Atomic Molecular and Optical Physics•Oct 25, 2018•9 citations

Coherent Control of Single Photons

Shengwang Du

•Jan 1, 2015•1 citation

Toward flexible intensity control of resonantly scattered γ -rays using multi-frequency vibrating resonant absorber

Aleš Stejskal, Vlastimil Vrba, Vít Procházka

We report a method for coherent control of γ-photons, enabling the shaping of γ-ray intensity in nearly arbitrary waveforms. Different intensity waveforms are created by adjusting the motion profile of a resonant absorber (an ensemble of Mössbauer nuclei) and tuning the energy of the incident radiation. A crucial aspect of this method is the use of a low fundamental frequency of vibrations, which broadens the possibilities for γ-ray control. The results of numerical simulations are experimentally validated by generating single and double γ-pulses and inducing short-term absorption. For this, a resonant absorber containing 57Fe nuclei was vibrated with different motion profiles composed of 12 harmonics with a fundamental frequency of 1 MHz. The proposed technique represents an advancement in the manipulation of γ-rays, and potentially x rays, paving the way for the performance of unique types of γ-ray or x-ray quantum experiments and the development of tools such as adjustable table-top γ-pulse sources or γ-ray or x-ray delays and gates. Moreover, inverse application of the method enables investigation of motion at the picometer scale.

arXiv:2410.05277•Applied Physics Letters•Feb 1, 2025•2 citations
Recently, an exponentially decaying waveform (the time dependence of detection probability) of a M\"ossbauer \ensuremath{\gamma}-ray photon was transformed into a regular sequence of short pulses in a sinusoidally vibrating recoilless resonant absorber [F. Vagizov, V. Antonov, Y. V. Radeonychev, R. N. Shakhmuratov, and O. Kocharovskaya, Coherent control of the waveforms of recoilless \ensuremath{\gamma}-photons, Nature (London) 508, 80 (2014)]. In the present paper, we show that the peak amplitude of the pulses can be considerably increased via joint adjustment of optical depth of the absorber and the initial phase of its vibration. This is due to reduction of the photoelectric absorption and maximizing the constructive temporal interference of spectral content of the single-photon wave packet in an optically deep absorber. The ultimate capabilities for transforming a waveform of a 14.4-keV photon from a 57Co^{57}\mathrm{Co}57Co radioactive source into a regular train of pulses in a harmonically vibrating 57Fe^{57}\mathrm{Fe}57Fe recoilless resonant absorber are discussed. We show that the shortest pulse duration, produced by this technique, is limited by the highest available vibration frequency of a piezoelectric transducer and at present can be as short as 7.7 ps. The maximum achievable detection probability of the transformed photon at the experimentally feasible conditions is more than two times higher than peak detection probability of the photon emitted by the source and nearly 5.5 times higher than obtained in the above reference.
Abstract The transformation of exponentially decaying waveform (the time dependence of detection probability) of a Mössbauer γ -ray photon into a regular sequence of short nearly bandwidth-limited pulses in a vibrating recoilless resonant absorber is studied. The case of dual-tone vibration at the fundamental frequency and its second harmonic under experimentally feasible conditions is considered. We show that this technique allows one to shorten pulses and increase the ratio of pulse separation to pulse length as well as to enlarge pulse amplitude compared to the pulses produced in harmonically vibrating absorber. The obtained results pave the way to the development of the time-resolved Mössbauer γ -ray spectroscopy and manipulation of quantum information in hard x-ray/ γ -ray range.
We report a method for coherent control of γ-photons, enabling the shaping of γ-ray intensity in nearly arbitrary waveforms. Different intensity waveforms are created by adjusting the motion profile of a resonant absorber (an ensemble of Mössbauer nuclei) and tuning the energy of the incident radiation. A crucial aspect of this method is the use of a low fundamental frequency of vibrations, which broadens the possibilities for γ-ray control. The results of numerical simulations are experimentally validated by generating single and double γ-pulses and inducing short-term absorption. For this, a resonant absorber containing 57Fe nuclei was vibrated with different motion profiles composed of 12 harmonics with a fundamental frequency of 1 MHz. The proposed technique represents an advancement in the manipulation of γ-rays, and potentially x rays, paving the way for the performance of unique types of γ-ray or x-ray quantum experiments and the development of tools such as adjustable table-top γ-pulse sources or γ-ray or x-ray delays and gates. Moreover, inverse application of the method enables investigation of motion at the picometer scale.