arXiv:1307.4524 · Annals of Physics

Weak values and weak coupling maximizing the output of weak measurements

Antonio Di Lorenzo

Published Mar 21, 2014• 13 citations
arXivHTMLPDF
DOI
10.1016/j.aop.2014.03.007

Related papers

Weak Value and Weak Measurements

Lev Vaidman A

Springer eBooks•Jan 1, 2009•7 citations

Full counting statistics of weak-value measurement

Antonio Di Lorenzo

A weak measurement consists of coupling a system to a probe in such a way that constructive interference generates a large output. So far, only the average output of the probe and its variance were studied. Here, the characteristic function for the moments of the output is provided. The outputs considered are not limited to the eigenstates of the pointer or of its conjugate variable, so the results apply to any observable $\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{o}$ of the probe. Furthermore, a family of well-behaved complex quantities, the normal weak values, is introduced, in terms of which the statistics of the weak measurement can be described. It is shown that, within a good approximation, the whole statistics of weak measurement is described by a complex parameter, the weak value, and a real one.

arXiv:1109.4183•Physical Review A•Mar 5, 2012•49 citations

Demystifying Weak Measurements

Ruth E. Kastner

arXiv:1702.04021•Foundations of Physics•Apr 8, 2017•25 citations

Simultaneous path weak-measurements in neutron interferometry

Armin Danner, Ismaele Vincent Masiello, Andreas Dvorak +4 more

The statistical properties of the detection events constituting the interference fringes at the output of an interferometer are well-known. Nevertheless, there is still no unified view of what is happening to a quantum system inside an interferometer. Strong measurements of path operators destroy the interference effect. In weak measurements, an observable is weakly coupled to a pointer system and the resulting weak values quantify the observable by minimally disturbing the system. Previous which-way experiments with weak measurements could extract either the real or imaginary part of a single weak value with each ensemble. Here, we present the simultaneous full complex quantification of two path weak values with a single ensemble in a Mach-Zehnder neutron interferometer. Magnetic fields, oscillating with different frequencies, change the energy state in each interferometer path. The time-dependent phase between the energy states distinctly marks each path. The resulting beating intensity modulation at the interferometer output gives both path weak values. For the present experiment, the weak values' absolute value and phase directly describe the observed amplitude and phase of the intensity modulation.

Scientific Reports•Oct 29, 2024•5 citations

Limits on amplification by Aharonov-Albert-Vaidman weak measurement

Tatsuhiko Koike, Saki Tanaka

We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.

arXiv:1108.2050•Physical Review A•Dec 5, 2011•60 citations

Reconstructing weak values without weak measurements

Lars M. Johansen

arXiv:0705.0108•Physics Letters A•Feb 17, 2007•26 citations
A weak measurement consists of coupling a system to a probe in such a way that constructive interference generates a large output. So far, only the average output of the probe and its variance were studied. Here, the characteristic function for the moments of the output is provided. The outputs considered are not limited to the eigenstates of the pointer or of its conjugate variable, so the results apply to any observable $\stackrel{\ifmmode \hat{}\else \^{}\fi{}}{o}$ of the probe. Furthermore, a family of well-behaved complex quantities, the normal weak values, is introduced, in terms of which the statistics of the weak measurement can be described. It is shown that, within a good approximation, the whole statistics of weak measurement is described by a complex parameter, the weak value, and a real one.
The statistical properties of the detection events constituting the interference fringes at the output of an interferometer are well-known. Nevertheless, there is still no unified view of what is happening to a quantum system inside an interferometer. Strong measurements of path operators destroy the interference effect. In weak measurements, an observable is weakly coupled to a pointer system and the resulting weak values quantify the observable by minimally disturbing the system. Previous which-way experiments with weak measurements could extract either the real or imaginary part of a single weak value with each ensemble. Here, we present the simultaneous full complex quantification of two path weak values with a single ensemble in a Mach-Zehnder neutron interferometer. Magnetic fields, oscillating with different frequencies, change the energy state in each interferometer path. The time-dependent phase between the energy states distinctly marks each path. The resulting beating intensity modulation at the interferometer output gives both path weak values. For the present experiment, the weak values' absolute value and phase directly describe the observed amplitude and phase of the intensity modulation.
We analyze the amplification by the Aharonov-Albert-Vaidman weak quantum measurement on a Sagnac interferometer [Dixon et al., Phys. Rev. Lett. 102, 173601 (2009)] up to all orders of the coupling strength between the measured system and the measuring device. The amplifier transforms a small tilt of a mirror into a large transverse displacement of the laser beam. The conventional analysis has shown that the measured value is proportional to the weak value, so that the amplification can be made arbitrarily large in the cost of decreasing output laser intensity. It is shown that the measured displacement and the amplification factor are in fact not proportional to the weak value and rather vanish in the limit of infinitesimal output intensity. We derive the optimal overlap of the pre- and postselected states with which the amplification become maximum. We also show that the nonlinear effects begin to arise in the performed experiments so that any improvements in the experiment, typically with an amplification greater than 100, should require the nonlinear theory in translating the observed value to the original displacement.