Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1307.3070 · Physical Review A

Optimal probabilistic measurement of phase

Petr Marek

Published Oct 18, 2013• 5 citations
arXivHTMLPDF

Abstract

When measuring the phase of quantum states of light, the optimal single-shot measurement implements a projection on the unphysical phase states. If we want to improve the precision further we need to accept a reduced probability of success, either by implementing a probabilistic measurement or by probabilistically manipulating the measured quantum state by means of noiseless amplification. We analyze the limits of this approach by finding the optimal probabilistic measurement that, for a given rate of success, maximizes the precision with which the phase can be measured.

DOI
10.1103/physreva.88.045802

Related papers

Phase estimation of coherent states with a noiseless linear amplifier

Syed M. Assad, Mark Bradshaw, Ping Koy Lam

Amplification of quantum states is inevitably accompanied with the introduction of noise at the output. For protocols that are probabilistic with heralded success, noiseless linear amplification in theory may still be possible. When the protocol is successful, it can lead to an output that is a noiselessly amplified copy of the input. When the protocol is unsuccessful, the output state is degraded and is usually discarded. Probabilistic protocols may improve the performance of some quantum information protocols, but not for metrology if the whole statistics is taken into consideration. We calculate the precision limits on estimating the phase of coherent states using a noiseless linear amplifier by computing its quantum Fisher information and we show that on average, the noiseless linear amplifier does not improve the phase estimate. We also discuss the case where abstention from measurement can reduce the cost for estimation.

arXiv:1608.01777•International Journal of Quantum Information•Feb 1, 2017•3 citations

Single-Shot Non-Gaussian Measurements for Optical Phase Estimation

M. T. DiMario, F. E. Becerra

Estimation of the properties of a physical system with minimal uncertainty is a central task in quantum metrology. Optical phase estimation is at the center of many metrological tasks where the value of a physical parameter is mapped to the phase of an electromagnetic field and single-shot measurements of this phase are necessary. While there are measurements able to estimate the phase of light in a single shot with small uncertainties, demonstrations of near-optimal single-shot measurements for an unknown phase of a coherent state remain elusive. Here, we propose and demonstrate strategies for single-shot measurements for ab initio phase estimation of coherent states that surpass the sensitivity limit of heterodyne measurement and approach the Cramer-Rao lower bound for coherent states. These single-shot estimation strategies are based on real-time optimization of coherent displacement operations, single photon counting with photon number resolution, and fast feedback. We show that our demonstration of these optimized estimation strategies surpasses the heterodyne limit for a wide range of optical powers without correcting for detection efficiency with a moderate number of adaptive measurement steps. This is, to our knowledge, the most sensitive single-shot measurement of an unknown phase encoded in optical coherent states.

arXiv:2008.08185•Physical Review Letters•Sep 18, 2020•12 citations

Probabilistic quantum multimeters

Jaromír Fiurášek, Miloslav Dušek

We propose quantum devices that can realize probabilistically different projective measurements on a qubit. The desired measurement basis is selected by the quantum state of a program register. First we analyze the phase-covariant multimeters for a large class of program states and then the universal multimeters for a special choice of program. In both cases we start with deterministic but error-prone devices and then proceed to devices that never make a mistake but from time to time give an inconclusive result. These multimeters are optimized (for a given type of program) with respect to the minimum probability of an inconclusive result. This concept is further generalized to multimeters that minimize the error rate for a given probability of an inconclusive result (or vice versa). Finally, we propose a generalization for qudits.

arXiv:quant-ph/0308111•Physical Review A•Mar 8, 2004•27 citations

On the measurement probability of quantum phases

Thomas Schürmann

We consider the probability by which quantum phase measurements of a given precision can be done successfully. The least upper bound of this probability is derived and the associated optimal state vectors are determined. The probability bound represents an unique and continuous transition between macroscopic and microscopic measurement precisions.

arXiv:quant-ph/0612171•Dec 20, 2006•0 citations

Optimal Quantum Measurements for Phase Estimation

Barry C. Sanders, Gerard J Milburn

Quantum information theory is applied to practical interferometer-based phase measurements to deduce the optimal phase measurement scheme with two optical modes. Optimal phase measurements, given ideal input states, reveal an asymptotic $1/n$ decrease in phase uncertainty $\ensuremath{\Delta}\ensuremath{\theta}$ for $n$ the mean photon number of the input state. In contradistinction to previous schemes for realizing the number-phase uncertainty limit, the $1/n$ limit achieved here is independent of the interferometer phase shift; prior information about the expected phase shift is not necessary to attain this limit. These results apply more generally to su(2) and so(3) phase parameter estimation.

Physical Review Letters•Oct 16, 1995•232 citations

Universality cost of non-Gaussian enhancement in continuous-variable quantum teleportation: A fidelity--deviation trade-off

Kyoungho Cho, Bongjune Kim, Jeongho Bang

Continuous-variable (CV) quantum teleportation is usually benchmarked by average fidelity, but when the teleportation is repeatedly used within optical networks or measurement-based architectures, uniformity across the input ensemble becomes equally important. We analyze this issue using two complementary figures of merit: the average fidelity and the fidelity deviation, which quantifies the input dependence of the single-shot teleportation fidelity. We prove that any deterministic unity-gain teleportation channel that is displacement covariant has vanishing fidelity deviation for coherent-state benchmarking, irrespective of whether the shared entangled resource is Gaussian or non-Gaussian. Nonzero deviation therefore diagnoses covariance breaking rather than non-Gaussianity. We then show that when a protocol raises the average fidelity through input-selective conditioning, the deviation generically increases in tandem, giving a quantitative universality cost. As a concrete example, we study teleportation enhanced by the so-called measurement-based noiseless linear amplification, where a heralded filter acts on the Bell-measurement record. The resulting trade-off among average fidelity, fidelity deviation, and success probability shows that stronger filtering can improve the conditional fidelity only by concentrating the successful events in favored regions of phase space, thereby suppressing the success probability and reducing input uniformity. Our results provide an operational framework for distinguishing genuine channel improvement from selectivity-driven post-selected advantage and suggest that the probabilistic CV teleportation should be assessed with average quality, universality, and heralding rate treated on an equal footing.

quant-pharXiv:2604.20103•Physical Review A•Apr 23, 2026•1 citation
When measuring the phase of quantum states of light, the optimal single-shot measurement implements a projection on the unphysical phase states. If we want to improve the precision further we need to accept a reduced probability of success, either by implementing a probabilistic measurement or by probabilistically manipulating the measured quantum state by means of noiseless amplification. We analyze the limits of this approach by finding the optimal probabilistic measurement that, for a given rate of success, maximizes the precision with which the phase can be measured.
Amplification of quantum states is inevitably accompanied with the introduction of noise at the output. For protocols that are probabilistic with heralded success, noiseless linear amplification in theory may still be possible. When the protocol is successful, it can lead to an output that is a noiselessly amplified copy of the input. When the protocol is unsuccessful, the output state is degraded and is usually discarded. Probabilistic protocols may improve the performance of some quantum information protocols, but not for metrology if the whole statistics is taken into consideration. We calculate the precision limits on estimating the phase of coherent states using a noiseless linear amplifier by computing its quantum Fisher information and we show that on average, the noiseless linear amplifier does not improve the phase estimate. We also discuss the case where abstention from measurement can reduce the cost for estimation.
Estimation of the properties of a physical system with minimal uncertainty is a central task in quantum metrology. Optical phase estimation is at the center of many metrological tasks where the value of a physical parameter is mapped to the phase of an electromagnetic field and single-shot measurements of this phase are necessary. While there are measurements able to estimate the phase of light in a single shot with small uncertainties, demonstrations of near-optimal single-shot measurements for an unknown phase of a coherent state remain elusive. Here, we propose and demonstrate strategies for single-shot measurements for ab initio phase estimation of coherent states that surpass the sensitivity limit of heterodyne measurement and approach the Cramer-Rao lower bound for coherent states. These single-shot estimation strategies are based on real-time optimization of coherent displacement operations, single photon counting with photon number resolution, and fast feedback. We show that our demonstration of these optimized estimation strategies surpasses the heterodyne limit for a wide range of optical powers without correcting for detection efficiency with a moderate number of adaptive measurement steps. This is, to our knowledge, the most sensitive single-shot measurement of an unknown phase encoded in optical coherent states.
We propose quantum devices that can realize probabilistically different projective measurements on a qubit. The desired measurement basis is selected by the quantum state of a program register. First we analyze the phase-covariant multimeters for a large class of program states and then the universal multimeters for a special choice of program. In both cases we start with deterministic but error-prone devices and then proceed to devices that never make a mistake but from time to time give an inconclusive result. These multimeters are optimized (for a given type of program) with respect to the minimum probability of an inconclusive result. This concept is further generalized to multimeters that minimize the error rate for a given probability of an inconclusive result (or vice versa). Finally, we propose a generalization for qudits.
Quantum information theory is applied to practical interferometer-based phase measurements to deduce the optimal phase measurement scheme with two optical modes. Optimal phase measurements, given ideal input states, reveal an asymptotic 1/n1/n1/n decrease in phase uncertainty $\ensuremath{\Delta}\ensuremath{\theta}$ for nnn the mean photon number of the input state. In contradistinction to previous schemes for realizing the number-phase uncertainty limit, the 1/n1/n1/n limit achieved here is independent of the interferometer phase shift; prior information about the expected phase shift is not necessary to attain this limit. These results apply more generally to su(2) and so(3) phase parameter estimation.
Continuous-variable (CV) quantum teleportation is usually benchmarked by average fidelity, but when the teleportation is repeatedly used within optical networks or measurement-based architectures, uniformity across the input ensemble becomes equally important. We analyze this issue using two complementary figures of merit: the average fidelity and the fidelity deviation, which quantifies the input dependence of the single-shot teleportation fidelity. We prove that any deterministic unity-gain teleportation channel that is displacement covariant has vanishing fidelity deviation for coherent-state benchmarking, irrespective of whether the shared entangled resource is Gaussian or non-Gaussian. Nonzero deviation therefore diagnoses covariance breaking rather than non-Gaussianity. We then show that when a protocol raises the average fidelity through input-selective conditioning, the deviation generically increases in tandem, giving a quantitative universality cost. As a concrete example, we study teleportation enhanced by the so-called measurement-based noiseless linear amplification, where a heralded filter acts on the Bell-measurement record. The resulting trade-off among average fidelity, fidelity deviation, and success probability shows that stronger filtering can improve the conditional fidelity only by concentrating the successful events in favored regions of phase space, thereby suppressing the success probability and reducing input uniformity. Our results provide an operational framework for distinguishing genuine channel improvement from selectivity-driven post-selected advantage and suggest that the probabilistic CV teleportation should be assessed with average quality, universality, and heralding rate treated on an equal footing.