arXiv:1307.2405 · Laser Physics Letters

Compensation of anisotropy effects in a nonlinear crystal for squeezed vacuum generation

A M Pérez, F Just, A Cavanna, Maria V. Chekhova, Gerd Leuchs

Published Oct 29, 2013• 14 citations
arXivHTMLPDF

Abstract

Squeezed vacuum can be obtained by an optical parametric amplifier (OPA) with the quantum vacuum state at the input. We are interested in a degenerate type-I OPA based on parametric down-conversion (PDC) where, due to phase matching requirements, an extraordinary polarized pump must impinge onto a birefringent crystal with a large χ (2) nonlinearity. As a consequence of the optical anisotropy of the medium, the spatial spectrum of the generated radiation is affected by the transverse walk-off. In this work we describe a method that reduces the spatial distortions, by using two consecutive crystals instead of one. We show that after anisotropy compensation the two-photon amplitude becomes symmetric, allowing for a simple Schmidt expansion, a procedure that in practice requires states that come from experimental systems free of anisotropy effects. Qualitative experimental observations are made for the case of high-gain PDC.

DOI
10.1088/1612-2011/10/12/125201

Related papers

Compensation of anisotropy effects in the generation of two-photon light

Andrea Cavanna, Angela M. Pérez, Felix Just +2 more

We analyse a method to compensate for anisotropy effects in the spatial distribution of parametric down-conversion (PDC) radiation in bulk crystals. In this method, a single nonlinear crystal is replaced by two consecutive crystals with opposite transverse walk-off directions. We implement a simple numerical model to calculate the spatial distribution of intensity and correlations, as well as the Schmidt mode structure, with an account for the anisotropy. Experimental results are presented which prove the validity of both the model and the method.

arXiv:1402.5888•Optics Express•Apr 17, 2014•7 citations

Bright correlated twin-beam generation and radiation shaping in high-gain parametric down-conversion with anisotropy

Matvei Riabinin, Polina R. Sharapova, T. Meier

Uniaxial anisotropy in nonlinear birefringent crystals limits the efficiency of nonlinear optical interactions and breaks the spatial symmetry of light generated in the parametric down-conversion (PDC) process. Therefore, this effect is usually undesirable and must be compensated for. However, high gain may be used to overcome the destructive role of anisotropy in order to generate bright two-mode correlated twin-beams. In this work, we provide a rigorous theoretical description of the spatial properties of bright squeezed light in the presence of strong anisotropy. We investigate a single crystal and a system of two crystals with an air gap (corresponding to a nonlinear SU(1,1) interferometer) and demonstrate the generation of bright correlated twin-beams in such configurations at high gain due to anisotropy. We explore the mode structure of the generated light and show how anisotropy, together with crystal spacing, can be used for radiation shaping.

arXiv:2103.04305•Optics Express•May 25, 2021•0 citations

Effect of spatial walk-off on squeezing properties of quantum optical frequency combs

Juan Li, Peng Liu, Xiao Xiang +3 more

Quantum optical frequency combs are of great significance in the fields of quantum computing, quantum information, and high precision quantum measurement, which can be produced by using a degenerate type-I synchronously pumped optical parametric oscillator (SPOPO). When anisotropic crystal is used as a nonlinear medium in the SPOPO, the spatial walk-off effect will occur due to the birefringence effect, which cannot be ignored and will adversely affect the generation of squeezed state. In this work, we investigate the influence of spatial walk-off effect on the squeezing level of quantum optical frequency combs both theoretically and experimentally. A Ti∶sapphire mode-locked femtosecond pulsed laser which produces 130 fs pulse trains at 815 nm with a repetition rate of 76 MHz is utilized as a fundamental source. Its second harmonic at 407.5 nm is used to pump the collinear BiB3O6 (BIBO) crystal for generating the squeezed vacuum frequency comb. It is indicated that as the crystal length increases, the area of interaction between pump light and signal light decreases gradually. Thus the enhancement of squeezing is eventually limited by the spatial walk-off effect. According to the simulations, the squeezing level reaches a maximum value when the crystal length is 1.49 mm. The quantum properties of squeezed vacuum optical frequency combs obtained for four crystal lengths (0.5, 1.0, 1.5 and 2.0 mm) are subsequently measured experimentally. When the length of BIBO is 1.5 mm, the maximum vacuum squeezing of (3.6±0.2) dB is obtained, which is (7.0±0.2) dB after being corrected for detection loss. The experimental results are consistent with the numerical simulations. This study demonstrates that the spatial walk-off effect in nonlinear crystal is a significant factor affecting the quantum optical frequency comb, and the theoretical model presented in this paper can be used to provide a guideline for optimizing the experimental implementation.

Acta Physica Sinica•Jan 1, 2023•1 citation

Single-cycle squeezing from chirped quasi-phase-matched optical parametric down-conversion

D. B. Horoshko, Mikhail I. Kolobov

Parametric down-conversion of light (PDC) in a quasi-phase-matched (QPM) nonlinear crystal can be spectrally very broad when the spatial frequency of periodical poling is linearly chirped. The present day technology makes possible the fabrication of chirped QPM crystals phase-matched for PDC in all optical spectrum. In the low-gain regime this allows for generation of biphotons with the correlation time of the order of a single optical cycle. A natural next step is the study of the PDC light produced by such a crystal in the high-gain regime, where PDC is widely used as a source of squeezed states of light. Up to now only a classical treatment of this regime was undertaken. In the present work we demonstrate a possibility to generate single-cycle squeezing in a chirped QPM nonlinear crystal with squeezing spectrum covering almost all the optical octave.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2013•0 citations

Pre- and post-compensation to suppress birefringent walk-off effects of entangled photons

Tianxuan Feng, Rong Fan, Ronghua Fan +6 more

Photon-based entanglement sources, crucial for obtaining entangled states, are typically generated via spontaneous parametric down-conversion. However, birefringence in nonlinear crystals causes spatial or temporal walk-off, reducing entangled photon quality. The theoretical analysis attributes birefringent walk-off to dispersive materials curbed by pre- and post-compensation. We experimentally validate this method, enhancing polarization-entangled photon quality. We measured the Bell state along with a violation of CHSH-Bell's inequality by ∼366 standard deviations (S = 2.623 ± 0.0017). Our approach, simple and stable, does not complicate setups. Its applicability extends to optimizing various entanglement source schemes, aiding optical quantum technologies such as computation, sensing, and communication.

Optics Express•Oct 13, 2024•4 citations

Quantum fluctuations in an optical parametric amplifier

Silvania F. Pereira, Z. Y. Ou, K. C. Peng +1 more

The nondegenerate optical parametric amplifier (OPA) has many uses for investigating quantum fluctuations of light. Among them are EPR-type quadrature-phase correlations,1 QND measurement,2 and phase-sensitive quantum amplification.3 To study these problems, a reliable high-gain low-loss optical parametric amplifier (OPA) is crucial. Although OPAs operated at 1064 nm with KTP crystals pumped by a frequency doubled YAG laser exist,1 their performance is compromised because of problems with beam walk-off and polarization mixing for pairs of critically phase-matched KTP crystals. To avoid such problems, we have constructed a different nondegenerate OPA, which is operated at 1080 nm and consists of a single KTP crystal with type II noncritical phase matching. The pump beam at 540 nm for the amplifier is obtained from intracavity frequency doubling of a single-mode Nd: YAP laser with a similar KTP crystal as in the OPA.

Annual Meeting Optical Society of America•Jan 1, 1991•0 citations
Squeezed vacuum can be obtained by an optical parametric amplifier (OPA) with the quantum vacuum state at the input. We are interested in a degenerate type-I OPA based on parametric down-conversion (PDC) where, due to phase matching requirements, an extraordinary polarized pump must impinge onto a birefringent crystal with a large χ (2) nonlinearity. As a consequence of the optical anisotropy of the medium, the spatial spectrum of the generated radiation is affected by the transverse walk-off. In this work we describe a method that reduces the spatial distortions, by using two consecutive crystals instead of one. We show that after anisotropy compensation the two-photon amplitude becomes symmetric, allowing for a simple Schmidt expansion, a procedure that in practice requires states that come from experimental systems free of anisotropy effects. Qualitative experimental observations are made for the case of high-gain PDC.
We analyse a method to compensate for anisotropy effects in the spatial distribution of parametric down-conversion (PDC) radiation in bulk crystals. In this method, a single nonlinear crystal is replaced by two consecutive crystals with opposite transverse walk-off directions. We implement a simple numerical model to calculate the spatial distribution of intensity and correlations, as well as the Schmidt mode structure, with an account for the anisotropy. Experimental results are presented which prove the validity of both the model and the method.
Uniaxial anisotropy in nonlinear birefringent crystals limits the efficiency of nonlinear optical interactions and breaks the spatial symmetry of light generated in the parametric down-conversion (PDC) process. Therefore, this effect is usually undesirable and must be compensated for. However, high gain may be used to overcome the destructive role of anisotropy in order to generate bright two-mode correlated twin-beams. In this work, we provide a rigorous theoretical description of the spatial properties of bright squeezed light in the presence of strong anisotropy. We investigate a single crystal and a system of two crystals with an air gap (corresponding to a nonlinear SU(1,1) interferometer) and demonstrate the generation of bright correlated twin-beams in such configurations at high gain due to anisotropy. We explore the mode structure of the generated light and show how anisotropy, together with crystal spacing, can be used for radiation shaping.
Quantum optical frequency combs are of great significance in the fields of quantum computing, quantum information, and high precision quantum measurement, which can be produced by using a degenerate type-I synchronously pumped optical parametric oscillator (SPOPO). When anisotropic crystal is used as a nonlinear medium in the SPOPO, the spatial walk-off effect will occur due to the birefringence effect, which cannot be ignored and will adversely affect the generation of squeezed state. In this work, we investigate the influence of spatial walk-off effect on the squeezing level of quantum optical frequency combs both theoretically and experimentally. A Ti∶sapphire mode-locked femtosecond pulsed laser which produces 130 fs pulse trains at 815 nm with a repetition rate of 76 MHz is utilized as a fundamental source. Its second harmonic at 407.5 nm is used to pump the collinear BiB3O6 (BIBO) crystal for generating the squeezed vacuum frequency comb. It is indicated that as the crystal length increases, the area of interaction between pump light and signal light decreases gradually. Thus the enhancement of squeezing is eventually limited by the spatial walk-off effect. According to the simulations, the squeezing level reaches a maximum value when the crystal length is 1.49 mm. The quantum properties of squeezed vacuum optical frequency combs obtained for four crystal lengths (0.5, 1.0, 1.5 and 2.0 mm) are subsequently measured experimentally. When the length of BIBO is 1.5 mm, the maximum vacuum squeezing of (3.6±0.2) dB is obtained, which is (7.0±0.2) dB after being corrected for detection loss. The experimental results are consistent with the numerical simulations. This study demonstrates that the spatial walk-off effect in nonlinear crystal is a significant factor affecting the quantum optical frequency comb, and the theoretical model presented in this paper can be used to provide a guideline for optimizing the experimental implementation.
Parametric down-conversion of light (PDC) in a quasi-phase-matched (QPM) nonlinear crystal can be spectrally very broad when the spatial frequency of periodical poling is linearly chirped. The present day technology makes possible the fabrication of chirped QPM crystals phase-matched for PDC in all optical spectrum. In the low-gain regime this allows for generation of biphotons with the correlation time of the order of a single optical cycle. A natural next step is the study of the PDC light produced by such a crystal in the high-gain regime, where PDC is widely used as a source of squeezed states of light. Up to now only a classical treatment of this regime was undertaken. In the present work we demonstrate a possibility to generate single-cycle squeezing in a chirped QPM nonlinear crystal with squeezing spectrum covering almost all the optical octave.
Photon-based entanglement sources, crucial for obtaining entangled states, are typically generated via spontaneous parametric down-conversion. However, birefringence in nonlinear crystals causes spatial or temporal walk-off, reducing entangled photon quality. The theoretical analysis attributes birefringent walk-off to dispersive materials curbed by pre- and post-compensation. We experimentally validate this method, enhancing polarization-entangled photon quality. We measured the Bell state along with a violation of CHSH-Bell's inequality by ∼366 standard deviations (S = 2.623 ± 0.0017). Our approach, simple and stable, does not complicate setups. Its applicability extends to optimizing various entanglement source schemes, aiding optical quantum technologies such as computation, sensing, and communication.
The nondegenerate optical parametric amplifier (OPA) has many uses for investigating quantum fluctuations of light. Among them are EPR-type quadrature-phase correlations,1 QND measurement,2 and phase-sensitive quantum amplification.3 To study these problems, a reliable high-gain low-loss optical parametric amplifier (OPA) is crucial. Although OPAs operated at 1064 nm with KTP crystals pumped by a frequency doubled YAG laser exist,1 their performance is compromised because of problems with beam walk-off and polarization mixing for pairs of critically phase-matched KTP crystals. To avoid such problems, we have constructed a different nondegenerate OPA, which is operated at 1080 nm and consists of a single KTP crystal with type II noncritical phase matching. The pump beam at 540 nm for the amplifier is obtained from intracavity frequency doubling of a single-mode Nd: YAP laser with a similar KTP crystal as in the OPA.