arXiv:1306.6321 · Physical Review X

When Amplification with Weak Values Fails to Suppress Technical Noise

George C. Knee, Erik M. Gauger

Published Mar 6, 2014• 177 citations
arXivHTMLPDF

Abstract

``Weak-value amplification,'' a quantum-mechanical phenomenon discovered only two decades ago, has received considerable interest for its potential as a metrological tool. However, its operation requires special circumstances, therefore carries costs. A new analysis shows that the associated costs outweigh the advantages when compared to other methods of signal amplification.

DOI
10.1103/physrevx.4.011032

Related papers

Weak-value amplification: state of play

George C. Knee, Joshua Combes, Christopher Ferrie +1 more

Abstract Weak values arise in quantum theory when the result of a weak measurement is conditioned on a subsequent strong measurement. The majority of the trials are discarded, leaving only very few successful events. Intriguingly those can display a substantial signal amplification. This raises the question of whether weak values carry potential to improve the performance of quantum sensors, and indeed a number of impressive experimental results suggested this may be the case. By contrast, recent theoretical studies have found the opposite: using weak-values to obtain an amplification generally worsens metrological performance. This survey summarises the implications of those studies, which call for a reappraisal of weak values’ utility and for further work to reconcile theory and experiment.

arXiv:1410.6252•Quantum Measurements and Quantum Metrology•Jan 1, 2016•39 citations

An Introduction to Weak Values

John C. Howell

I will give a brief background to weak values, discuss their implications and review some of the recent experiments employing weak value techniques including: weak value amplification, wave function measurement and technical noise suppression. Article not available.

Latin America Optics and Photonics Conference•Jan 1, 2014•0 citations

Technical Advantages for Weak-Value Amplification: When Less Is More

Andrew N. Jordan, Julián Martínez-Rincón, John C. Howell

``Weak-value amplification,'' an interference effect that was introduced quantum mechanically, but can also be realized using classical electromagnetic waves, uses only a small fraction of the available events to make precise measurements. How can this be? Theorists reveal that weak-value amplification achieves that by funneling all the information into a small fraction of events.

arXiv:1309.5011•Physical Review X•Mar 6, 2014•316 citations

Weak-measurement-enhanced Metrology in the Presence of CCD Noise and Saturation

Liang Xu, Zexuan Liu, Lijian Zhang

We experimentally demonstrate that the measurement using weak value amplification offers metrological advantages over the conventional measurement in the presence of classical noise and detection saturation with a generic scientific CCD.

Frontiers in Optics•Jan 1, 2018•2 citations

Weak Values and Balanced Homodyne Detection Working Together

Julián Martínez-Rincón, Wei-Tao Liu, Gerardo I. Viza +1 more

We present a metrological technique which, without discarding of data, resembles a larger anomalous amplification than weak-value-amplification (WVA). The protocol surpasses WVA techniques by amplifying an almost-balanced homodyne signal.

Frontiers in Optics•Jan 1, 2016•0 citations

Noise resilience in the transition regime of inverse weak-value amplification metrology

Zi-Rui Zhong, Shuang Song, Qian He +3 more

We demonstrate the superior robustness of the transition regime in inverse weak-value amplification (IWVA) metrology against key experimental noise sources. For standard IWVA schemes, the transition regime provides enhanced resilience compared to the conventional IWVA regime when subjected to uncorrelated Gaussian technical noise and phase fluctuations. While a larger beam width σ generally suppresses technical noise, we identify that phase fluctuations impose a strict upper bound on the optimal σ . In power-recycled IWVA schemes, where cavity loss and the inherent walk-off effect typically degrade the signal, the transition regime maintains a consistent advantage. Our findings establish the transition regime as the optimal operational point for high-precision measurements, balancing significant signal amplification with robustness against practical noise in both standard and power-recycled configurations.

Journal of the Optical Society of America B•Jun 2, 2026•0 citations
``Weak-value amplification,'' a quantum-mechanical phenomenon discovered only two decades ago, has received considerable interest for its potential as a metrological tool. However, its operation requires special circumstances, therefore carries costs. A new analysis shows that the associated costs outweigh the advantages when compared to other methods of signal amplification.
Abstract Weak values arise in quantum theory when the result of a weak measurement is conditioned on a subsequent strong measurement. The majority of the trials are discarded, leaving only very few successful events. Intriguingly those can display a substantial signal amplification. This raises the question of whether weak values carry potential to improve the performance of quantum sensors, and indeed a number of impressive experimental results suggested this may be the case. By contrast, recent theoretical studies have found the opposite: using weak-values to obtain an amplification generally worsens metrological performance. This survey summarises the implications of those studies, which call for a reappraisal of weak values’ utility and for further work to reconcile theory and experiment.
We demonstrate the superior robustness of the transition regime in inverse weak-value amplification (IWVA) metrology against key experimental noise sources. For standard IWVA schemes, the transition regime provides enhanced resilience compared to the conventional IWVA regime when subjected to uncorrelated Gaussian technical noise and phase fluctuations. While a larger beam width σ generally suppresses technical noise, we identify that phase fluctuations impose a strict upper bound on the optimal σ . In power-recycled IWVA schemes, where cavity loss and the inherent walk-off effect typically degrade the signal, the transition regime maintains a consistent advantage. Our findings establish the transition regime as the optimal operational point for high-precision measurements, balancing significant signal amplification with robustness against practical noise in both standard and power-recycled configurations.