arXiv:1305.5708 · Quantum Matter

Quantum and Classical Characterization of Single/Few Photon Detectors

M. G. Mingolla, Fabrizio Piacentini, Alessio Avella, Marco Gramegna, L. Lolli, Alice Meda, Ivano Ruo Berchera, E. Taralli, P. Traina, M. Rajteri, G. Brida, Ivo Pietro Degiovanni, Marco Genovese

Published Jun 1, 2015• 2 citations
arXivHTMLPDF

Abstract

This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we focus on photon-number-resolving detectors, discussing both the classical and quantum characterization of such devices.

DOI
10.1166/qm.2015.1275

Related papers

Quantum Characterization of Single Photon Detectors

M. G. Mingolla

The research activities described in this thesis have basically an experimental profile, and were realized in the Quantum Optics Laboratories of the Optic Division in the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.). The experiments presented here are oriented to the characterization of single- and few-photon detectors calibration, exploiting quantum properties. The first chapter has an introductory character, oriented to the study of nonlinear optics phenomena and focused in the spontaneous parametric down conversion (PDC) process. After the quantization of the free electromagnetic field, we recall the quantum theory of PDC. In the second chapter the Klyshko's two-photon calibration technique is presented and applied to an Avalanche Photo Diode (APD) based single photon counting module. Chapter three is an introduction to quantum measurements and quantum operation theories where the concept of positive-operator valued measurement (POVM) is presented. In chapter four, the quantum characterization of a true photon-number resolving detector (PNRD) based on a transition edge sensor (TES) is presented. In this experiment, the POVM of the TES is reconstructed by realizing a tomography of the detection process's quantum operation, using as a probe a set of known coherent states. In the fifth and last chapter, the POVM of a tree type PNRD is reconstructed exploiting strong quantum correlations of PDC twin beams

•Jan 1, 2014•0 citations

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•26 citations

Single photon sources for quantum radiometry: a brief review about the current state-of-the-art

S. Kück, Marco López, Helmuth Hofer +17 more

Abstract Single-photon sources have a variety of applications. One of these is quantum radiometry, which is reported on in this paper in the form of an overview, specifically of the current state of the art in the application of deterministic single photon sources to the calibration of single photon detectors. To optimize single-photon sources for this purpose, extensive research is currently carried out at the European National Metrology Institutes (NMIs), in collaboration with partners from universities. Single-photon sources of different types are currently under investigation, including sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots. We will present, summarise, and compare the current results obtained at European NMIs for single-photon sources in terms of photon flux, single-photon purity, and spectral power distribution as well as the results of single-photon detector calibrations carried out with this type of light sources.

Applied Physics B•Jan 23, 2022•13 citations

TOWARDS THE IMPLEMENTATION OF A SINGLE-PHOTON DETECTOR ABSOLUTE CALIBRATION SYSTEM WITH CORRELATED PHOTON-PAIRS

T. Ferreira da Silva, I B Couceiro, H.P. Grieneisen +1 more

Abstract − An experimental system using correlated photon pairs for absolute measurements of single-photon detectors quantum efficiency has been set up at the Brazilian National Institute of Metrology (INMETRO). The establishment of this methodology is of special significance for the absolute calibration of detectors, especially for near infrared range as an alternative to the conventional radiometric methods. This paper describes the preliminary implementation of this absolute calibration method. Our first experimental results are reported and the optimization of the system is pointed out for obtaining further improvements the near future.

•Jan 1, 2009•0 citations

Single photon sources for absolute radiometry – A review about the current state of the art

S. Kück

In this presentation a review about the current state of the art concerning the application of deterministic single photon sources for absolute radiometry, i.e. the calibration of single photon detectors, is given. At the Physikalisch-Technische Bundesanstalt, the German national Metrology institute, an extensive research is carried out to optimize single photon sources for this purpose. Different single photon sources are currently under investigation, these are sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots.

Measurement Sensors•Oct 19, 2021•9 citations

Metrology of single-photon sources and detectors: a review

Christopher J. Chunnilall, Ivo Pietro Degiovanni, S. Kück +2 more

The generation, measurement, and manipulation of light at the single- and few-photon levels underpin a rapidly expanding range of applications. These range from applications moving into the few-photon regime in order to achieve improved sensitivity and/or energy efficiency, as well as new applications that operate solely in this regime, such as quantum key distribution and physical quantum random number generation. There is intensive research to develop new quantum optical technologies, for example, quantum sensing, simulation, and computing. These applications rely on the performance of the single-photon sources and detectors they employ; this review article gives an overview of the methods, both conventional and recently developed, that are available for measuring the performance of these devices, with traceability to the SI system.

Optical Engineering•Jul 10, 2014•191 citations
This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we focus on photon-number-resolving detectors, discussing both the classical and quantum characterization of such devices.
The research activities described in this thesis have basically an experimental profile, and were realized in the Quantum Optics Laboratories of the Optic Division in the Istituto Nazionale di Ricerca Metrologica (I.N.Ri.M.). The experiments presented here are oriented to the characterization of single- and few-photon detectors calibration, exploiting quantum properties. The first chapter has an introductory character, oriented to the study of nonlinear optics phenomena and focused in the spontaneous parametric down conversion (PDC) process. After the quantization of the free electromagnetic field, we recall the quantum theory of PDC. In the second chapter the Klyshko's two-photon calibration technique is presented and applied to an Avalanche Photo Diode (APD) based single photon counting module. Chapter three is an introduction to quantum measurements and quantum operation theories where the concept of positive-operator valued measurement (POVM) is presented. In chapter four, the quantum characterization of a true photon-number resolving detector (PNRD) based on a transition edge sensor (TES) is presented. In this experiment, the POVM of the TES is reconstructed by realizing a tomography of the detection process's quantum operation, using as a probe a set of known coherent states. In the fifth and last chapter, the POVM of a tree type PNRD is reconstructed exploiting strong quantum correlations of PDC twin beams
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
Abstract Single-photon sources have a variety of applications. One of these is quantum radiometry, which is reported on in this paper in the form of an overview, specifically of the current state of the art in the application of deterministic single photon sources to the calibration of single photon detectors. To optimize single-photon sources for this purpose, extensive research is currently carried out at the European National Metrology Institutes (NMIs), in collaboration with partners from universities. Single-photon sources of different types are currently under investigation, including sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots. We will present, summarise, and compare the current results obtained at European NMIs for single-photon sources in terms of photon flux, single-photon purity, and spectral power distribution as well as the results of single-photon detector calibrations carried out with this type of light sources.
Abstract − An experimental system using correlated photon pairs for absolute measurements of single-photon detectors quantum efficiency has been set up at the Brazilian National Institute of Metrology (INMETRO). The establishment of this methodology is of special significance for the absolute calibration of detectors, especially for near infrared range as an alternative to the conventional radiometric methods. This paper describes the preliminary implementation of this absolute calibration method. Our first experimental results are reported and the optimization of the system is pointed out for obtaining further improvements the near future.
In this presentation a review about the current state of the art concerning the application of deterministic single photon sources for absolute radiometry, i.e. the calibration of single photon detectors, is given. At the Physikalisch-Technische Bundesanstalt, the German national Metrology institute, an extensive research is carried out to optimize single photon sources for this purpose. Different single photon sources are currently under investigation, these are sources based on defect centres in (nano-)diamonds, on molecules and on semiconductor quantum dots.
The generation, measurement, and manipulation of light at the single- and few-photon levels underpin a rapidly expanding range of applications. These range from applications moving into the few-photon regime in order to achieve improved sensitivity and/or energy efficiency, as well as new applications that operate solely in this regime, such as quantum key distribution and physical quantum random number generation. There is intensive research to develop new quantum optical technologies, for example, quantum sensing, simulation, and computing. These applications rely on the performance of the single-photon sources and detectors they employ; this review article gives an overview of the methods, both conventional and recently developed, that are available for measuring the performance of these devices, with traceability to the SI system.