arXiv:1304.4533 · Journal of Applied Physics

An analysis method for transmission measurements of superconducting resonators with applications to quantum-regime dielectric-loss measurements

Chunqing Deng, Martin R. Otto, Adrian Lupaşcu

Published Aug 6, 2013• 32 citations
arXivHTMLPDF

Abstract

Superconducting resonators provide a convenient way to measure loss tangents of various dielectrics at low temperature. For the purpose of examining the microscopic loss mechanisms in dielectrics, precise measurements of the internal quality factor at different values of energy stored in the resonators are required. Here, we present a consistent method to analyze a LC superconducting resonator coupled to a transmission line. We first derive an approximate expression for the transmission S-parameter S21(ω), with ω the excitation frequency, based on a complete circuit model. In the weak coupling limit, we show that the internal quality factor is reliably determined by fitting the approximate form of S21(ω). Since the voltage V of the capacitor of the LC circuit is required to determine the energy stored in the resonator, we next calculate the relation between V and the forward propagating wave voltage Vin+, with the latter being the parameter controlled in experiments. Due to the dependence of the quality factor on voltage, V is not simply proportional to Vin+. We find a self-consistent way to determine the relation between V and Vin+, which employs only the fitting parameters for S21(ω) and a linear scaling factor. We then examine the resonator transmission in the cases of port reflection and impedance mismatch. We find that resonator transmission asymmetry is primarily due to the reflection from discontinuity in transmission lines. We show that our analysis method to extract the internal quality factor is robust in the non-ideal cases above. Finally, we show that the analysis method used for the LC resonator can be generalized to arbitrary weakly coupled lumped and distributed resonators. The generalization uses a systematic approximation on the response function based on the pole and zero which are closest to the resonance frequency. This Closest Pole and Zero Method is a valuable tool for analyzing physical measurements of high-Q resonators.

DOI
10.1063/1.4817512

Related papers

An analysis method for asymmetric resonator transmission applied to superconducting devices

M. S. Khalil, M. J. A. Stoutimore, F. C. Wellstood +1 more

We examine the transmission through nonideal microwave resonant circuits. The general analytical resonance line shape is derived for both inductive and capacitive coupling with mismatched input and output transmission impedances, and it is found that, for certain non-ideal conditions, the line shape is asymmetric. We describe an analysis method for extracting an accurate internal quality factor (Qi), the diameter correction method (DCM), and compare it to the conventional method used for millikelvin resonator measurements, the φ rotation method (φRM). We analytically find that the φRM deterministically overestimates Qi when the asymmetry of the resonance line shape is high, and that this error is eliminated with the DCM. A consistent discrepancy between the two methods is observed when they are used to analyze both simulations from a numerical linear solver and data from asymmetric coplanar superconducting thin-film resonators.

arXiv:1108.3117•Journal of Applied Physics•Mar 1, 2012•313 citations

Network modeling of non-ideal superconducting resonator circuits

H. Guan, M Dai, Qing He +5 more

Abstract We originally develop a network analysis method to study the non-ideal superconducting resonator circuits. We model the resonator device by a 3-block serial network, consisting of input feedline, resonator-coupler and output feedline. We show that the resonance curve will be modified if non-negligible discontinuity (reflection) exists at input or output side of the resonator. The extracted resonance parameters (such as coupling quality factor Q c ) from only fitting the transmission deviate from their true values as originally defined in matched impedance conditions, and the deviation depends on a single parameter which includes all the non-ideal effects from the circuits. We prove that the internal quality factor Q i can be accurately extracted from the modified transmission curve by using a very simple graphical method. Our methods and results are quantitatively verified by both simulations and experiments on superconducting microstrip resonators. Comparing to the usual circuit analysis, our network analysis method is more intuitive and easier to understand. It can serve as a general tool to study the non-ideal superconducting resonator circuits.

Superconductor Science and Technology•Apr 16, 2020•13 citations

Measuring Reactive-Load Impedance with Transmission-Line Resonators Beyond the Perturbative Limit

Xuanjing Chu, Jinho Park, Jesse Balgley +8 more

We develop an analytic framework to extract circuit parameters and loss tangent from superconducting transmission-line resonators terminated by reactive loads, extending analysis beyond the perturbative regime. The formulation yields closed-form relations between resonant frequency, participation ratio, and internal quality factor, removing the need for full-wave simulations. We validate the framework through circuit simulations, finite-element modeling, and experimental measurements of van der Waals parallel-plate capacitors, using it to extract the dielectric constant and loss tangent of hexagonal boron nitride. Statistical analysis across multiple reference resonators, together with multimode self-calibration, demonstrates consistent and reproducible extraction of both capacitance and loss tangent in close agreement with literature values. In addition to parameter extraction, the analytic relations provide practical design guidelines for maximizing energy participation ratio in the load and improving the precision of resonator-based material metrology.

quant-pharXiv:2511.14621•Physical Review Applied•Nov 19, 2025•2 citations

New method for fitting complex resonance curve to study nonlinear superconducting resonators

Xingyun Dai, X Liu, Qing He +8 more

Abstract We present a new fitting method that can robustly and accurately fit the complex transmission curve of a superconducting resonator in the nonlinear regime. This method takes into account the varying internal current in the resonator at different frequencies and the nonlinear dependence of the inductance on the internal current L = L 0 ( 1 + I 2 / I ∗ 2 ) , where I ∗ is a characteristic current. We demonstrate using this method to retrieve important resonator parameters, such as the quality factor and the resonance frequency, from resonators driven below, near, and above bifurcation. We further use this method to retrieve I ∗ for lumped-element TiN resonators with various inductor designs. By fitting the resonance frequency shift at different readout powers of each resonator, we can determine the characteristic current I ∗ , which is found to be linearly related to the cross-sectional area of the narrow inductor strip. Our method has wide applications in superconducting detector, superconducting qubit and parametric amplifier data analysis where the resonator is driven in the nonlinear regime.

Superconductor Science and Technology•Nov 21, 2022•9 citations

Analysis and calibration techniques for superconducting resonators

Giuseppe Cataldo, Edward J. Wollack, Emily M. Barrentine +3 more

A method is proposed and experimentally explored for in-situ calibration of complex transmission data for superconducting microwave resonators. This cryogenic calibration method accounts for the instrumental transmission response between the vector network analyzer reference plane and the device calibration plane. Once calibrated, the observed resonator response is analyzed in detail by two approaches. The first, a phenomenological model based on physically realizable rational functions, enables the extraction of multiple resonance frequencies and widths for coupled resonators without explicit specification of the circuit network. In the second, an ABCD-matrix representation for the distributed transmission line circuit is used to model the observed response from the characteristic impedance and propagation constant. When used in conjunction with electromagnetic simulations, the kinetic inductance fraction can be determined with this method with an accuracy of 2%. Datasets for superconducting microstrip and coplanar-waveguide resonator devices were investigated and a recovery within 1% of the observed complex transmission amplitude was achieved with both analysis approaches. The experimental configuration used in microwave characterization of the devices and self-consistent constraints for the electromagnetic constitutive relations for parameter extraction are also presented.

arXiv:1411.1343•Review of Scientific Instruments•Jan 1, 2015•18 citations

Cryogenic single-port calibration for superconducting microwave resonator measurements

H. Wang, Suren Singh, Corey Rae McRae +8 more

Abstract Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.

arXiv:2103.01491•Quantum Science and Technology•Jun 1, 2021•38 citations
Superconducting resonators provide a convenient way to measure loss tangents of various dielectrics at low temperature. For the purpose of examining the microscopic loss mechanisms in dielectrics, precise measurements of the internal quality factor at different values of energy stored in the resonators are required. Here, we present a consistent method to analyze a LC superconducting resonator coupled to a transmission line. We first derive an approximate expression for the transmission S-parameter S21(ω), with ω the excitation frequency, based on a complete circuit model. In the weak coupling limit, we show that the internal quality factor is reliably determined by fitting the approximate form of S21(ω). Since the voltage V of the capacitor of the LC circuit is required to determine the energy stored in the resonator, we next calculate the relation between V and the forward propagating wave voltage Vin+, with the latter being the parameter controlled in experiments. Due to the dependence of the quality factor on voltage, V is not simply proportional to Vin+. We find a self-consistent way to determine the relation between V and Vin+, which employs only the fitting parameters for S21(ω) and a linear scaling factor. We then examine the resonator transmission in the cases of port reflection and impedance mismatch. We find that resonator transmission asymmetry is primarily due to the reflection from discontinuity in transmission lines. We show that our analysis method to extract the internal quality factor is robust in the non-ideal cases above. Finally, we show that the analysis method used for the LC resonator can be generalized to arbitrary weakly coupled lumped and distributed resonators. The generalization uses a systematic approximation on the response function based on the pole and zero which are closest to the resonance frequency. This Closest Pole and Zero Method is a valuable tool for analyzing physical measurements of high-Q resonators.
We examine the transmission through nonideal microwave resonant circuits. The general analytical resonance line shape is derived for both inductive and capacitive coupling with mismatched input and output transmission impedances, and it is found that, for certain non-ideal conditions, the line shape is asymmetric. We describe an analysis method for extracting an accurate internal quality factor (Qi), the diameter correction method (DCM), and compare it to the conventional method used for millikelvin resonator measurements, the φ rotation method (φRM). We analytically find that the φRM deterministically overestimates Qi when the asymmetry of the resonance line shape is high, and that this error is eliminated with the DCM. A consistent discrepancy between the two methods is observed when they are used to analyze both simulations from a numerical linear solver and data from asymmetric coplanar superconducting thin-film resonators.
Abstract We originally develop a network analysis method to study the non-ideal superconducting resonator circuits. We model the resonator device by a 3-block serial network, consisting of input feedline, resonator-coupler and output feedline. We show that the resonance curve will be modified if non-negligible discontinuity (reflection) exists at input or output side of the resonator. The extracted resonance parameters (such as coupling quality factor Q c ) from only fitting the transmission deviate from their true values as originally defined in matched impedance conditions, and the deviation depends on a single parameter which includes all the non-ideal effects from the circuits. We prove that the internal quality factor Q i can be accurately extracted from the modified transmission curve by using a very simple graphical method. Our methods and results are quantitatively verified by both simulations and experiments on superconducting microstrip resonators. Comparing to the usual circuit analysis, our network analysis method is more intuitive and easier to understand. It can serve as a general tool to study the non-ideal superconducting resonator circuits.
We develop an analytic framework to extract circuit parameters and loss tangent from superconducting transmission-line resonators terminated by reactive loads, extending analysis beyond the perturbative regime. The formulation yields closed-form relations between resonant frequency, participation ratio, and internal quality factor, removing the need for full-wave simulations. We validate the framework through circuit simulations, finite-element modeling, and experimental measurements of van der Waals parallel-plate capacitors, using it to extract the dielectric constant and loss tangent of hexagonal boron nitride. Statistical analysis across multiple reference resonators, together with multimode self-calibration, demonstrates consistent and reproducible extraction of both capacitance and loss tangent in close agreement with literature values. In addition to parameter extraction, the analytic relations provide practical design guidelines for maximizing energy participation ratio in the load and improving the precision of resonator-based material metrology.
Abstract We present a new fitting method that can robustly and accurately fit the complex transmission curve of a superconducting resonator in the nonlinear regime. This method takes into account the varying internal current in the resonator at different frequencies and the nonlinear dependence of the inductance on the internal current L = L 0 ( 1 + I 2 / I ∗ 2 ) , where I ∗ is a characteristic current. We demonstrate using this method to retrieve important resonator parameters, such as the quality factor and the resonance frequency, from resonators driven below, near, and above bifurcation. We further use this method to retrieve I ∗ for lumped-element TiN resonators with various inductor designs. By fitting the resonance frequency shift at different readout powers of each resonator, we can determine the characteristic current I ∗ , which is found to be linearly related to the cross-sectional area of the narrow inductor strip. Our method has wide applications in superconducting detector, superconducting qubit and parametric amplifier data analysis where the resonator is driven in the nonlinear regime.
A method is proposed and experimentally explored for in-situ calibration of complex transmission data for superconducting microwave resonators. This cryogenic calibration method accounts for the instrumental transmission response between the vector network analyzer reference plane and the device calibration plane. Once calibrated, the observed resonator response is analyzed in detail by two approaches. The first, a phenomenological model based on physically realizable rational functions, enables the extraction of multiple resonance frequencies and widths for coupled resonators without explicit specification of the circuit network. In the second, an ABCD-matrix representation for the distributed transmission line circuit is used to model the observed response from the characteristic impedance and propagation constant. When used in conjunction with electromagnetic simulations, the kinetic inductance fraction can be determined with this method with an accuracy of 2%. Datasets for superconducting microstrip and coplanar-waveguide resonator devices were investigated and a recovery within 1% of the observed complex transmission amplitude was achieved with both analysis approaches. The experimental configuration used in microwave characterization of the devices and self-consistent constraints for the electromagnetic constitutive relations for parameter extraction are also presented.
Abstract Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.