We design and fabricate two types of superconducting niobium coplanar waveguide microwave resonators with different coupling capacitors on high purity Si substrates. Their microwave transmissions are measured at 20 mK. It is found that these two types of resonators possess significantly different loaded quality factors; one is 5.6 × 10 3 and the other is 4.0 × 10 4 . The measured data are fitted well by classical ABCD matrix approach and consequently the coupling capacitances are determined. It is found that the transmission peak deviates from the standard Lorentizian with a frequency broadening.
We design and fabricate two types of superconducting niobium coplanar waveguide microwave resonators with different coupling capacitors on high purity Si substrates. Their microwave transmissions are measured at 20 mK. It is found that these two types of resonators possess significantly different loaded quality factors; one is 5.6 × 10 3 and the other is 4.0 × 10 4 . The measured data are fitted well by classical ABCD matrix approach and consequently the coupling capacitances are determined. It is found that the transmission peak deviates from the standard Lorentizian with a frequency broadening.
We successfully designed and fabricated an absorption-type of superconducting coplanar waveguide (CPW) resonators. The resonators are made from a niobium film (about 160 nm thick) on a high-resistance Si substrate, and each resonator is fabricated as a meandered quarter-wavelength transmission line (one end is short to the ground and another end is capacitively coupled to a through feedline). With a vector network analyzer we measured the transmissions of the applied microwave through the resonators at ultra-low temperature. The obtained loaded quality factors are significantly high, i.e. up to ∼10 6 . When the temperature increases slowly from the base temperature (20 mK), the resonance frequencies of the resonators are blue shifted and the quality factors are lowered slightly. In principle, this type of device can integrate a series of CPW resonators with a common feedline, making it a promising candidate as the data bus for coupling distant solid-state qubits and the sensitive detector of single photons.
The use of a transmission line resonator offers the possibility for different sensor readout methods, e.g. flux qubit and kinetic inductance detectors. Both cases require a high quality factor, Q L , of the cavity circuit to detect small deviations in the resonance frequency. Various superconducting niobium coplanar waveguide resonators of λ/4 and λ/2 wavelength for 3 and 6 GHz were developed. Different layouts for the coplanar resonators were designed, simulated and measured on common silicon and sapphire substrates at 4.2 K. We found a very good agreement between simulation and measurement results, with Q L between 10 4 and 10 5 at helium temperatures. The presented results show the dependences on the chosen cross section geometries, the coupling factor and the complex layout of the transmission line.
The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.
We report our development on design, fabrication and characterization of various superconducting resonators for quantum device applications. The resonators are developed mainly for superconducting qubit implementation in circuit QED structure, but future application will include photon detectors such as microwave kinetic inductance detectors. First we designed and fabricated half-wavelength coplanar waveguide resonators with niobium thin film on a high resistive silicon wafer, with the fundamental frequencies in the range of 1 to 8 GHz. The loaded quality factors are controlled by the coupling capacitors, and the lower bound of the intrinsic quality factor was measured down to 7 mK in the dilution refrigerator. We have also designed quarter-wavelength resonators and lumped LC resonators coupled to a transmission line, and characterized multiple resonators in a single transmission line. For the 3D transmon qubit application, we designed and fabricated a rectangular box resonator with superconducting aluminum. The intrinsic quality factor of the box resonator exceeds three million at 7 mK. We will also present basic results on the integration of a transmon qubit in the superconducting resonator.
The high critical magnetic field and relatively high critical temperature of niobium nitride (NbN) make it a promising material for applications in superconducting quantum technology. However, NbN-based superconducting circuits are sensitive to decoherence sources such as two-level system (TLS) defects. Here, we numerically and experimentally investigate NbN superconducting microwave coplanar waveguide resonator arrays with a 100 nm thickness, capacitively coupled to a common coplanar waveguide on a silicon chip. We observe that the resonators' internal quality factor (Qi) decreases fromQi∼1.07×106in a high power regime toQi∼1.36×105in the single photon regime. Data from this study is consistent with the TLS theory, which describes the TLS interactions in resonator substrates and interfaces. Moreover, we study the temperature (T) dependence ofQiand resonance frequencyfrof coplanar waveguide resonators to characterize the quasiparticle density. We observe that the increase in kinetic inductance at higher temperatures is the main reason for the frequency shift. Finally, we measurefrandQiin response to in-plane magnetic fields (B∣∣). We verify thatQistays well above104up toB∣∣= 240 mT in the photon number<nph>= 1.8 atT= 100 mK. Our results could enable the development of robust microwave superconducting circuits for circuit quantum electrodynamics at high magnetic fields required for hybrid superconducting-semiconducting quantum circuits.
In this master's thesis, I present the design, fabrication, and characterisation of superconducting microwave resonators. These resonators are quarter-wavelength coplanar waveguide resonators, operating at resonance frequencies between 4 GHz and 8 GHz. This kind of resonator is a key component in several applications, ranging from quantum computation devices to parametric amplifiers. Minimising the losses (achieving high internal quality factors) in these resonators is important to maximise performance of the applications they are used for. During the thesis work, we have studied several possible changes to improve the resonator quality.\n\nFabrication of the resonators was done in the Nanofabrication Laboratory at Chalmers University of Technology, and consist of the following steps: cleaning a sapphire or silicon wafer, depositing a layer of superconducting niobium, photolithography, and etching the waveguide. We then measured the resonators in a cryogen-free dilution refrigerator, at a temperature of 10 mK. The measurements consisted of a power sweep, in order to quantify the quality factor at high and low excitation powers. As an example, the first resonator we fabricated had a quality factor of 4.3 x 10^4 at high power (about 10^5 photons in the resonator), and quality factor of 3.7 x 10^4 at the single-photon level.\n\nWe then investigated different loss mechanisms that we expect to negatively affect the quality factor, and how to reduce this loss. Firstly, to reduce radiation losses and magnetic vortex losses, we reduced the lateral dimensions of the resonator. Secondly, as two-level system (TLS) losses are believed to mainly reside at the surfaces of the materials and interfaces between them, we etched into the substrate to selectively move a part of the TLS away from the resonator. We also studied the effect of the meandering of the resonator on the quality factor, as well as using two different etching gasses.\n\nBy gathering all this data, we were then able to compare the different combinations to see the effect of the changing parameters. In conclusion, the reduced lateral dimensions and the removal of part of the substrate indeed reduce the losses, as expected from the theory. We also found interesting behaviour with regards to the meandering, namely that having a meandered structure negatively affects the quality factor.\n\nCombining all results, we can give a guideline for the fabrication of resonators in the future, which gave us a quality factor up to 4.9 x 10^5 at high excitation power, and 3.0 x 10^5 at the single photon level.