Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1301.1170 · Physical Review Letters

Optimal Design and Quantum Benchmarks for Coherent State Amplifiers

Giulio Chiribella, Jinyu Xie

Published May 22, 2013• 42 citations
arXivHTMLPDF

Abstract

We establish the ultimate quantum limits to the amplification of an unknown coherent state, both in the deterministic and probabilistic case, investigating the realistic scenario where the expected photon number is finite. In addition, we provide the benchmark that experimental realizations have to surpass in order to beat all classical amplification strategies and to demonstrate genuine quantum amplification. Our result guarantees that a successful demonstration is in principle possible for every finite value of the expected photon number.

DOI
10.1103/physrevlett.110.213602

Related papers

Quantum amplification and purification of noisy coherent states

Xiaobin Zhao, Giulio Chiribella

Quantum-limited amplifiers increase the amplitude of quantum signals at the price of introducing additional noise. Quantum purification protocols operate in the reverse way, by reducing the noise while attenuating the signal. Here we investigate a scenario that interpolates between these two extremes. We search for the optimal physical process that generates $M$ approximate copies of a pure and amplified coherent state, starting from $N$ copies of a noisy coherent state with Gaussian modulation. We prove that the optimal deterministic processes are always Gaussian, whereas non-Gaussianity powers up probabilistic advantages in suitable parameter regimes. The optimal processes are experimentally realizable with current technology, both in the deterministic and in the probabilistic scenario. In view of this fact, we provide benchmarks that can be used to certify the experimental demonstration of the quantum-enhanced amplification and purification of coherent states.

arXiv:1701.04602•Physical Review A•Apr 4, 2017•15 citations

Truly noiseless probabilistic amplification

Vedran Dunjko, Erika Andersson

Most of the schemes for ``noiseless'' amplification of coherent states, which have recently been attracting theoretical and experimental interest, share a common trait: The amplification is not truly noiseless, or perfect, for nonzero success probability. While this must hold true for all phase-independent amplification schemes, in this work we point out that truly noiseless amplification is indeed possible, provided that the states which we wish to amplify come from a finite set. Perfect amplification with unlimited average gain is then possible with finite success probability, for example, using techniques for unambiguously distinguishing between quantum states. Such realizations require only linear optics, no single-photon sources, and no photon counting. We also investigate the optimal success probability of perfect amplification of a symmetric set of coherent states. There are two regimes: low-amplitude amplification, where the target amplitude is below one, and general amplification. For the low-amplitude regime, analytic results for the optimal amplification success probabilities can be obtained. In this case a natural bound imposed by the ratio of success probabilities of optimal unambiguous discrimination of the source and amplified states can always be reached. We also show that for general amplification this bound cannot always be satisfied.

arXiv:1811.08670•Physical Review A•Oct 18, 2012•15 citations

Benchmarking the state comparison amplifier

Klaudia Kleczkowska, Ittoop Vergheese Puthoor, Lauren Bain +1 more

The state comparison amplifier is a recently proposed probabilistic quantum amplifier, intended especially for amplifying coherent states. Its realization is simple and uses only linear optics and photodetectors, and the preparation of a ``guess'' state, typically a coherent state. Fidelity and success probability can be high compared with other probabilistic amplifiers. State comparison amplification does, however, extract information about the amplified state, which means that it is especially important to benchmark it against a simple measure-and-resend procedure. We compare state comparison quantum amplifiers to measure-and-resend strategies, and identify parameter regimes and scenarios where these can and where they cannot provide an advantage.

Physical Review A•Oct 9, 2017•1 citation

A heralded quantum amplifier of multi-photon states

Luis Villegas-Aguilar, Farzad Ghafari, Matthew S. Winnel +5 more

Large-scale quantum networking systems will inevitably require methods to overcome photon loss. While the no-cloning theorem forbids perfect and deterministic amplification of unknown quantum states, probabilistic heralded amplification schemes offer a viable path forward. Yet, for over a decade, successful multi-photon state amplification has remained out of reach, despite the fundamental importance of such states in achieving quantum advantage in optical applications. Here, we experimentally demonstrate a high-fidelity and post-selection-free amplifier for multi-photon states. We achieve heralded amplification of states with up to two photons in a single optical mode, with over a hundredfold intensity gain, and verify the coherence-preserving operation of our scheme. Our approach is scalable to higher photon numbers and enables noiseless amplification of complex multi-photon quantum states, with applications in large-scale quantum communication systems, distributed quantum metrology, and information processing.

arXiv:2505.13992•May 20, 2025•0 citations

Coherent-state phase concentration by quantum probabilistic amplification

Petr Marek, Radim Filip

We propose a probabilistic measurement-induced amplification for coherent states. The amplification scheme uses a counterintuitive architecture: a thermal noise addition (instead of a single-photon addition) followed by a feasible multiple-photon subtraction using a realistic photon-number-resolving detector. It allows one to substantially amplify weak coherent states and simultaneously reduce their phase uncertainty, which is impossible when using a deterministic Gaussian amplifier.

arXiv:0907.2402•Physical Review A•Feb 4, 2010•98 citations

A learning scheme with coherent state receiver (Conference Presentation)

Luca Mazzarella, Ross J. Donaldson, Robert John Collins +5 more

The laws of quantum mechanics pose stringent constraints on the amplification of a quantum signal. Deterministic amplification of an unknown quantum state always implies the addition of a minimal amount of noise. In principle, linear and noiseless amplification is allowed provided it works only probabilistically [1,2]. The state comparison amplifier [3] is an approximate probabilistic amplifier that amplifies a coherent state chosen at random from a set of coherent states with known mean photon number. The amplification process works as follows: Alice picks uniformly at random an input state and passes it to Bob. He desires to amplify the state so he mixes it with a guess coherent state at a beam splitter in an attempt to achieve destructive interference in one of the output arms. This output is fed into an APD detector. The lack of trigger at the detector is an imperfect indication that Bob’s guess is right and that the output contains the correct amplified state. On the other hand, if the first detector fires Bob knows that his guess was wrong but he can still correct the output by changing the input state for a second amplification stage via a feed-forward loop. In summary, Bob declares success when both the detectors do not fire or when the first detector does fire and state correction is performed. We generalize this mechanism for an arbitrary number of input states and beam splitters, using an on-line learning strategy based on maximum a posteriori probability. The success probability-fidelity product [2] of the SCAMP is the joint probability of success and of passing a measurement test on the output comparing it to right amplified state. Our figures of merit compare favorably with other schemes. The success probability-fidelity product of the SCAMP is always bigger than that of a USD based amplifier [2] that, when inconclusive, delivers a conveniently chosen random output. The SCAMP can be realized with classical resources (i.e., lasers, linear optics and APD detectors), the ability to switch between input states on the fly requires delay lines and fast switching but it can still be achieved with classical resources and the loss introduced by the delay can be offset at the second stage. Similar systems, with no state correction, proved to achieve high-gain, high fidelity and high repetition rates, e.g. [4, 5]. Due to its simplicity, the system we propose might represent an ideal candidate either as a recovery station to counteract quantum signal degradation due to propagation in a lossy fibre or across the turbulent atmosphere or as a quantum receiver to improve the key-rate of continuous-variable quantum key distribution with discrete modulation. The system is also suitable for on-chip implementation. [1] T.C. Ralph & A.P. Lund, Proceedings of the 9th QCMC Conference 2009. [2] S. Pandey, et al., Phys. Rev. A 88, 033852 (2013). [3] E. Eleftheriadou et al., Phys. Rev. Lett. 111, 213601 (2013). [4] R. Donaldson et al., Phys. Rev. Lett. 114, 120505 (2015). [5] R. Donaldson et al., in preparation.

SPIE Quantum Information Science and Technology•Oct 11, 2018•0 citations
We establish the ultimate quantum limits to the amplification of an unknown coherent state, both in the deterministic and probabilistic case, investigating the realistic scenario where the expected photon number is finite. In addition, we provide the benchmark that experimental realizations have to surpass in order to beat all classical amplification strategies and to demonstrate genuine quantum amplification. Our result guarantees that a successful demonstration is in principle possible for every finite value of the expected photon number.
Quantum-limited amplifiers increase the amplitude of quantum signals at the price of introducing additional noise. Quantum purification protocols operate in the reverse way, by reducing the noise while attenuating the signal. Here we investigate a scenario that interpolates between these two extremes. We search for the optimal physical process that generates MMM approximate copies of a pure and amplified coherent state, starting from NNN copies of a noisy coherent state with Gaussian modulation. We prove that the optimal deterministic processes are always Gaussian, whereas non-Gaussianity powers up probabilistic advantages in suitable parameter regimes. The optimal processes are experimentally realizable with current technology, both in the deterministic and in the probabilistic scenario. In view of this fact, we provide benchmarks that can be used to certify the experimental demonstration of the quantum-enhanced amplification and purification of coherent states.
Most of the schemes for ``noiseless'' amplification of coherent states, which have recently been attracting theoretical and experimental interest, share a common trait: The amplification is not truly noiseless, or perfect, for nonzero success probability. While this must hold true for all phase-independent amplification schemes, in this work we point out that truly noiseless amplification is indeed possible, provided that the states which we wish to amplify come from a finite set. Perfect amplification with unlimited average gain is then possible with finite success probability, for example, using techniques for unambiguously distinguishing between quantum states. Such realizations require only linear optics, no single-photon sources, and no photon counting. We also investigate the optimal success probability of perfect amplification of a symmetric set of coherent states. There are two regimes: low-amplitude amplification, where the target amplitude is below one, and general amplification. For the low-amplitude regime, analytic results for the optimal amplification success probabilities can be obtained. In this case a natural bound imposed by the ratio of success probabilities of optimal unambiguous discrimination of the source and amplified states can always be reached. We also show that for general amplification this bound cannot always be satisfied.
The state comparison amplifier is a recently proposed probabilistic quantum amplifier, intended especially for amplifying coherent states. Its realization is simple and uses only linear optics and photodetectors, and the preparation of a ``guess'' state, typically a coherent state. Fidelity and success probability can be high compared with other probabilistic amplifiers. State comparison amplification does, however, extract information about the amplified state, which means that it is especially important to benchmark it against a simple measure-and-resend procedure. We compare state comparison quantum amplifiers to measure-and-resend strategies, and identify parameter regimes and scenarios where these can and where they cannot provide an advantage.
Large-scale quantum networking systems will inevitably require methods to overcome photon loss. While the no-cloning theorem forbids perfect and deterministic amplification of unknown quantum states, probabilistic heralded amplification schemes offer a viable path forward. Yet, for over a decade, successful multi-photon state amplification has remained out of reach, despite the fundamental importance of such states in achieving quantum advantage in optical applications. Here, we experimentally demonstrate a high-fidelity and post-selection-free amplifier for multi-photon states. We achieve heralded amplification of states with up to two photons in a single optical mode, with over a hundredfold intensity gain, and verify the coherence-preserving operation of our scheme. Our approach is scalable to higher photon numbers and enables noiseless amplification of complex multi-photon quantum states, with applications in large-scale quantum communication systems, distributed quantum metrology, and information processing.
The laws of quantum mechanics pose stringent constraints on the amplification of a quantum signal. Deterministic amplification of an unknown quantum state always implies the addition of a minimal amount of noise. In principle, linear and noiseless amplification is allowed provided it works only probabilistically [1,2]. The state comparison amplifier [3] is an approximate probabilistic amplifier that amplifies a coherent state chosen at random from a set of coherent states with known mean photon number. The amplification process works as follows: Alice picks uniformly at random an input state and passes it to Bob. He desires to amplify the state so he mixes it with a guess coherent state at a beam splitter in an attempt to achieve destructive interference in one of the output arms. This output is fed into an APD detector. The lack of trigger at the detector is an imperfect indication that Bob’s guess is right and that the output contains the correct amplified state. On the other hand, if the first detector fires Bob knows that his guess was wrong but he can still correct the output by changing the input state for a second amplification stage via a feed-forward loop. In summary, Bob declares success when both the detectors do not fire or when the first detector does fire and state correction is performed. We generalize this mechanism for an arbitrary number of input states and beam splitters, using an on-line learning strategy based on maximum a posteriori probability. The success probability-fidelity product [2] of the SCAMP is the joint probability of success and of passing a measurement test on the output comparing it to right amplified state. Our figures of merit compare favorably with other schemes. The success probability-fidelity product of the SCAMP is always bigger than that of a USD based amplifier [2] that, when inconclusive, delivers a conveniently chosen random output. The SCAMP can be realized with classical resources (i.e., lasers, linear optics and APD detectors), the ability to switch between input states on the fly requires delay lines and fast switching but it can still be achieved with classical resources and the loss introduced by the delay can be offset at the second stage. Similar systems, with no state correction, proved to achieve high-gain, high fidelity and high repetition rates, e.g. [4, 5]. Due to its simplicity, the system we propose might represent an ideal candidate either as a recovery station to counteract quantum signal degradation due to propagation in a lossy fibre or across the turbulent atmosphere or as a quantum receiver to improve the key-rate of continuous-variable quantum key distribution with discrete modulation. The system is also suitable for on-chip implementation. [1] T.C. Ralph & A.P. Lund, Proceedings of the 9th QCMC Conference 2009. [2] S. Pandey, et al., Phys. Rev. A 88, 033852 (2013). [3] E. Eleftheriadou et al., Phys. Rev. Lett. 111, 213601 (2013). [4] R. Donaldson et al., Phys. Rev. Lett. 114, 120505 (2015). [5] R. Donaldson et al., in preparation.