Measurement of the Coulomb Logarithm in a Radio-Frequency Paul Trap

Kuang Chen, Scott T. Sullivan, Wade G. Rellergert, Eric R. Hudson

Published Apr 23, 2013• 25 citations
arXivHTMLPDF

Abstract

Samples of ultracold 174Yb+ ions, confined in a linear radio-frequency Paul trap, are heated via micromotion interruption, while their temperature, density, and therefore structural phase are monitored and simulated. The observed time evolution of the ion temperature is compared to a theoretical model for ion-ion heating allowing a direct measurement of the Coulomb logarithm in a linear Paul trap. This result permits a simple, yet accurate, analytical description of ion cloud thermodynamic properties, e.g., density, temperature, and structural phase, as well as suggests limits to and improvements for ongoing trapped-ion quantum information efforts.

DOI
10.1103/physrevlett.110.173003

Related papers

Dynamics of charged particles in a Paul radio-frequency quadrupole trap

John D. Prestage, Ann Katherine Williams, Lute Maleki +2 more

We have carried out a molecular-dynamics simulation of hundreds of ions confined in a Paul trap. The simulation includes the trapped particles' micromotion and interparticle Coulomb interactions. We have implemented a random walk in velocity to bring the secular motion to a given temperature which we have numerically measured. When the coupling \ensuremath{\Gamma} is large the ions form concentric shells which undergo a quadrupole oscillation at the rf frequency, while the ions within a shell form a 2D hexagonal lattice. Ion clouds at 5 mK show no rf heating for ${\mathit{q}}_{\mathit{z}}$\ensuremath{\lesssim}0.6, whereas rapid heating is seen for ${\mathit{q}}_{\mathit{z}}$=0.8.

Physical Review Letters•Jun 10, 1991•66 citations

Experimental setup for studying an ultracold mixture of trapped Yb+–Li6

Henrik Hirzler, Thomas Feldker, Henning A. Fürst +7 more

We describe and characterize an experimental apparatus that has been used to study interactions between ultracold lithium atoms and ytterbium ions. The preparation of ultracold clouds of Li atoms is described as well as their subsequent transport and overlap with ${\mathrm{Yb}}^{+}$ ions trapped in a Paul trap. We show how the kinetic energy of the ion after interacting with the atoms can be obtained by laser spectroscopy. We analyze the dynamics of the buffer-gas-cooled ion after releasing the atoms, which indicates that background heating, due to electric-field noise, limits attainable buffer gas cooling temperatures. This effect can be mitigated by increasing the density of the Li gas in order to improve its cooling power. Imperfections in the Paul trap lead to so-called excess micromotion, which poses another limitation to the buffer gas cooling. We describe in detail how we measure and subsequently minimize excess micromotion in our setup. We measure the effect of excess micromotion on attainable ion temperatures after buffer gas cooling and compare this to molecular dynamics simulations, which describe the observed data very well.

arXiv:2005.06375•Physical Review A•Sep 18, 2020•12 citations

Toward Production of Ultracold Molecular Ions

Kuang Chen

Ultracold cold molecular ions promise new directions in various studies of fundamental physics, such as precision measurements, ultracold chemistry and quantum information sciences. All these exciting applications require the molecular ion to be prepared at ground state of motional and internal degrees of freedom. It has been proposed that this stringent goal could be achieved through sympa-thetic cooling via collisions with laser-cooled neutral atoms. Three fundamentalissues of this method are addressed in this thesis.First, an analytical model is established to accurately describe collision-induced heating of a single ion in contact with cold neutral atoms. This model reveals that micromotion interruption is the cause of heating, and gives results about steady-state temperature and sympathetic cooling rate verified by Monte-Carlo simulations. It also provides insight into the power-law tails observed in theenergy distribution of the trapped ion.Next, we consider the case of multiple ions, whose inter-particle Coulomb repulsion causes ions in the Coulomb crystal state to spontaneously melt into a gas phase ion cloud, due to the same micromotion interruption mechanism. The analysis of this problem with a plasma model leads to the experimental determination of a quantity central to plasma physics, Coulomb Logarithm, in anion trap.Finally, we demonstrate a molecular ion spectroscopy technique through the example of trap-depletion photodissociation of BaCl + . Although not sensitive to rotational structure, this method already reveals much about the fundamental quantum physics in the photodissociation process. The measured cross-section results paves the road toward state-selective spectroscopy currently going on in our lab.

•Jan 1, 2013•0 citations

Improving Molecular Dynamics Simulations of Ion Coulomb Crystals in Linear Paul Traps

Kevin M Loeffler

Molecular dynamics simulations of ion Coulomb crystals in linear Paul traps allow for the extraction of properties such as ion temperature and ion counts enabling the investigation of ion chemistry in the ultra-cold regime. These simulations reproduce experimental CCD images using density plots of simulated ions allowing for comparisons to be drawn between simulated and experimental results and providing information inaccessible to the researcher, such as the locations of clouds of non- uorescing species. In this thesis, a method for creating these simulated CCD images is presented, as well as the demonstration of a fourth order integrator for producing more accurate calculations of the ion energy. The simulation of a single frequency Paul trap is presented and the ability to match simulations with experimental parameters as inputs to experimental results is demonstrated in order to show that the simulations that have been constructed can be used to analyze experimental data and work as a predictive lab tool for future explorations of ultra-cold chemistry.

•Jan 1, 2017•0 citations

Second-order Doppler frequency shifts of trapped ions in a linear Paul trap

S. N. Miao, Jianwei Zhang, Yajing Zheng +5 more

The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS of ions. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a model to accurately evaluate the total SODFS for an ion ensemble with temperature less than 100 mK, which consists of three contributions of ion motion. The effectiveness of the model has been verified by MD simulation, and the experimental results of the excess micromotion of trapped ions are consistent with the theory. We believe that our model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.

arXiv:2206.08136•Physical Review A•Sep 29, 2022•8 citations

Quantum analysis of atom-ion sympathetic cooling in the presence of micromotion

Michał Krych, Zbigniew Idziaszek

We investigate the problem of a single ion in a radio-frequency trap and immersed in an ultracold Bose gas either in condensed or non-condensed phase. We develop master equation formalism describing the sympathetic cooling and we determine the cooling rates and final energies of ions. We show that cold atomic reservoir modifies the stability diagram of the ion in the Paul trap creating the regions where the ion is either cooled or heated due to the energy quanta exchanged with the time-dependent potential. Our calculation indicates that micromotion constitutes an important source of heating limiting the final temperature of ions to values higher than 100$\mu$K for parameters of present experiments.

Bulletin of the American Physical Society•Dec 1, 2013•0 citations
Samples of ultracold 174Yb+ ions, confined in a linear radio-frequency Paul trap, are heated via micromotion interruption, while their temperature, density, and therefore structural phase are monitored and simulated. The observed time evolution of the ion temperature is compared to a theoretical model for ion-ion heating allowing a direct measurement of the Coulomb logarithm in a linear Paul trap. This result permits a simple, yet accurate, analytical description of ion cloud thermodynamic properties, e.g., density, temperature, and structural phase, as well as suggests limits to and improvements for ongoing trapped-ion quantum information efforts.
We have carried out a molecular-dynamics simulation of hundreds of ions confined in a Paul trap. The simulation includes the trapped particles' micromotion and interparticle Coulomb interactions. We have implemented a random walk in velocity to bring the secular motion to a given temperature which we have numerically measured. When the coupling \ensuremath{\Gamma} is large the ions form concentric shells which undergo a quadrupole oscillation at the rf frequency, while the ions within a shell form a 2D hexagonal lattice. Ion clouds at 5 mK show no rf heating for qz{\mathit{q}}_{\mathit{z}}qz​\ensuremath{\lesssim}0.6, whereas rapid heating is seen for qz{\mathit{q}}_{\mathit{z}}qz​=0.8.
We describe and characterize an experimental apparatus that has been used to study interactions between ultracold lithium atoms and ytterbium ions. The preparation of ultracold clouds of Li atoms is described as well as their subsequent transport and overlap with Yb+{\mathrm{Yb}}^{+}Yb+ ions trapped in a Paul trap. We show how the kinetic energy of the ion after interacting with the atoms can be obtained by laser spectroscopy. We analyze the dynamics of the buffer-gas-cooled ion after releasing the atoms, which indicates that background heating, due to electric-field noise, limits attainable buffer gas cooling temperatures. This effect can be mitigated by increasing the density of the Li gas in order to improve its cooling power. Imperfections in the Paul trap lead to so-called excess micromotion, which poses another limitation to the buffer gas cooling. We describe in detail how we measure and subsequently minimize excess micromotion in our setup. We measure the effect of excess micromotion on attainable ion temperatures after buffer gas cooling and compare this to molecular dynamics simulations, which describe the observed data very well.
Ultracold cold molecular ions promise new directions in various studies of fundamental physics, such as precision measurements, ultracold chemistry and quantum information sciences. All these exciting applications require the molecular ion to be prepared at ground state of motional and internal degrees of freedom. It has been proposed that this stringent goal could be achieved through sympa-thetic cooling via collisions with laser-cooled neutral atoms. Three fundamentalissues of this method are addressed in this thesis.First, an analytical model is established to accurately describe collision-induced heating of a single ion in contact with cold neutral atoms. This model reveals that micromotion interruption is the cause of heating, and gives results about steady-state temperature and sympathetic cooling rate verified by Monte-Carlo simulations. It also provides insight into the power-law tails observed in theenergy distribution of the trapped ion.Next, we consider the case of multiple ions, whose inter-particle Coulomb repulsion causes ions in the Coulomb crystal state to spontaneously melt into a gas phase ion cloud, due to the same micromotion interruption mechanism. The analysis of this problem with a plasma model leads to the experimental determination of a quantity central to plasma physics, Coulomb Logarithm, in anion trap.Finally, we demonstrate a molecular ion spectroscopy technique through the example of trap-depletion photodissociation of BaCl + . Although not sensitive to rotational structure, this method already reveals much about the fundamental quantum physics in the photodissociation process. The measured cross-section results paves the road toward state-selective spectroscopy currently going on in our lab.
Molecular dynamics simulations of ion Coulomb crystals in linear Paul traps allow for the extraction of properties such as ion temperature and ion counts enabling the investigation of ion chemistry in the ultra-cold regime. These simulations reproduce experimental CCD images using density plots of simulated ions allowing for comparisons to be drawn between simulated and experimental results and providing information inaccessible to the researcher, such as the locations of clouds of non- uorescing species. In this thesis, a method for creating these simulated CCD images is presented, as well as the demonstration of a fourth order integrator for producing more accurate calculations of the ion energy. The simulation of a single frequency Paul trap is presented and the ability to match simulations with experimental parameters as inputs to experimental results is demonstrated in order to show that the simulations that have been constructed can be used to analyze experimental data and work as a predictive lab tool for future explorations of ultra-cold chemistry.
The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS of ions. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a model to accurately evaluate the total SODFS for an ion ensemble with temperature less than 100 mK, which consists of three contributions of ion motion. The effectiveness of the model has been verified by MD simulation, and the experimental results of the excess micromotion of trapped ions are consistent with the theory. We believe that our model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.
We investigate the problem of a single ion in a radio-frequency trap and immersed in an ultracold Bose gas either in condensed or non-condensed phase. We develop master equation formalism describing the sympathetic cooling and we determine the cooling rates and final energies of ions. We show that cold atomic reservoir modifies the stability diagram of the ion in the Paul trap creating the regions where the ion is either cooled or heated due to the energy quanta exchanged with the time-dependent potential. Our calculation indicates that micromotion constitutes an important source of heating limiting the final temperature of ions to values higher than 100μ\muμK for parameters of present experiments.