Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1205.2241 · New Journal of Physics

Tomographic readout of an opto-mechanical interferometer

H. Kaufer, A. Sawadsky, Tobias Westphal, Daniel Friedrich, Roman Schnabel

Published Sep 21, 2012• 7 citations
arXivHTMLPDF

Abstract

The quantum state of light changes its nature when being reflected off a mechanical oscillator due to the latter's susceptibility to radiation pressure. As a result, a coherent state can transform into a squeezed state and can get entangled with the motion of the oscillator. Full information of the state of light can only be gathered by a tomographic measurement. Here we demonstrate a tomographic interferometer readout by measuring arbitrary quadratures of the light field exiting a Michelson–Sagnac interferometer that contains a thermally excited high-quality silicon nitride membrane. A readout noise of 1.9 × 10 −16 m Hz −1/2 around the membrane's fundamental oscillation mode at 133 kHz has been achieved, going below the peak value of the standard quantum limit by a factor of 8.2 (9 dB). The readout noise was entirely dominated by shot noise in a rather broad frequency range around the mechanical resonance.

DOI
10.1088/1367-2630/14/9/095018

Related papers

Interferometer readout noise below the standard quantum limit of a membrane

T. Westphal, D. Friedrich, H. Kaufer +7 more

Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of, i.e., membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.16em}{0ex}}\mathrm{m}/\sqrt{\mathrm{Hz}}$ at frequencies around the fundamental resonance of a SiN${}_{\mathrm{x}}$ membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This margin is significantly bigger than those of previous works with nanowires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and emphasize that neither our nor previous experiments achieved a total noise spectral density as low as the SQL due to thermal noise.

Physical Review A•Jun 6, 2012•25 citations

Sensitivity Enhancement of Optomechanical Measurements using Squeezed Light

L. Kleybolte

The quantum mechanical description of electromagnetic fields predicts fluctuations in their amplitude and phase quadrature, that underlay Heisenberg's uncertainty relation. When reflected by an object, the fields induce a radiation pressure force. The amplitude uncertainty causes fluctuations of this force, resulting in quantum radiation pressure noise. The standard quantum limit sets a lower bound for the sum of radiation pressure noise and shot noise, that will dominate the sensitivity of future gravitational-wave detectors. In optomechanics the radiation pressure noise is investigated. One fundamental goal is to undercut the standard quantum limit by applying squeezed states, that have a reduced variance in one quadrature and an amplified variance in the orthogonal. A shot noise reduction of 2.2 dB in an optomechanical table top experiment can be found in the literature. In this work squeezed states were produced in a nonlinear crystal via degenerate parametric down-conversion. At a sideband frequency of 400 kHz a squeeze factor of (8.7+/-0.2) dB was measured. In a first experiment the setup was used to demonstrate how internal squeezing can improve the sensitivity of an interferometric measurement. An increase of the sensitivity-bandwidth product of 36% was experimentally observed for an artificially generated signal. This thesis further presents a cryogenic optomechanical experiment with a silicon nitride membrane as mechanical oscillator. The topology of a Michelson-Sagnac interferometer was chosen to realize a Michelson interferometer with the membrane as end mirror despite its low reflectivity. A contrast of the outcoming modes of 99.7% was reached for temperatures down to 100 K. The signal at the dark fringe allowed a measurement with a shot-noise limited sensitivity for an input power of 50 muW. After calibrating the measured spectra with the theoretical shot noise, the quality factors of the membrane Q_293=2.7*10^5 and Q_100=1,5*10^6 at 293K and 100K could be determined from the resulting displacement spectral density. By injecting externally produced squeezed states, the quantum shot noise in the presented experiment was reduced by (3.1+-0.2) dB, which corresponds to a factor of sqrt(2) in the linear displacement spectral density. For a radiation-pressure-noise limited sensitivity, the demonstrated application of squeezed states could allow to overcome the standard quantum limit in the future. Aus der quantenmechanischen Beschreibung elektromagnetischer Felder folgen Fluktuationen in deren Amplituden- und Phasenquadratur, die der Heisenbergsche Unscharferelation unterliegen. Wenn die Felder von einem Objekt reflektiert werden, erzeugen sie eine Strahlungsdruckkraft. Die Fluktuationen dieser Kraft aufgrund der Amplitudenunscharfe verursachen das Quanten-Strahlungsdruckrauschen. Das Standardquantenlimit ist der Minimalwert fur die Summe aus Strahlungsdruckrauschen und Schrotrauschen, der in Zukunft die Sensitivitat von Gravitationswellendetektoren limitieren wird. In der Optomechanik wird das Strahlungsdruckrauschen erforscht. Ein fundamentales Ziel ist das Uberwinden des Standardquantenlimits durch die Anwendung gequetschter Zustande, deren Varianz in einer Quadratur vermindert aber in der orthogonalen erhoht ist. In der Literatur findet man eine Schrotrauschreduktion von 2.2 dB in einem optomechanischem Tischaufbau. In dieser Arbeit wurden gequetschte Zustande mithilfe der parametrischen Abkonversion in einem nichtlinearen Kristall generiert. Bei einer Seitenbandfrequenz von 400 kHz wurde ein Quetschfaktor von (8.7+-0.2) dB gemessen. In einem ersten Experiment mit dem Aufbau wurde demonstriert, wie intern produzierte gequetschte Zustande die Sensitivitat einer interferometrischen Messung verbessern konnen. Ein Anstieg des Sensitivitat-Bandbreite-Produkts von 36% wurde fur ein kunstlich generiertes Signal experimentell beobachtet. Es wird weiterhin ein kryogenes optomechanisches Experiment mit einer Siliziumnitrid-Membran als mechanischer Oszillator prasentiert. Die Topologie des Michelson-Sagnac-Interferometers wurde gewahlt um trotz ihrer geringen Reflektivitat ein Michelson-Interferometer mit der Membran als Endspiegel zu realisieren. Fur Temperaturen bis minimal 100K konnte ein Kontrast der Moden im Ausgang von 99.7% erreicht werden. Das Signal im dunklen Ausgang ermoglichte eine Messung mit einer vom Schrotrauschen limitierten Sensitivitat fur eine Eingangsleistung von 50 muW. Nach der Kalibrierung der gemessenen Spektren mit dem theoretischen Schrotrauschen konnten die Gutefaktoren der Membran Q_293=2.7*10^5 und Q_100=1.5*10^6 bei 293K und 100K aus der resultierenden spektrale Dichte der Ortsanderung bestimmt werden. Durch die Injektion extern produzierter gequetschter Zustande wurde das Quantenschrotrauschen im prasentierten Experiment um (3.1 +/-0.2) dB gesenkt, was einem Faktor Wurzel(2) in der linearen spektralen Rauschdichte entspricht. Fur eine vom Strahlungsdruckrauschen limitierte Sensitivitat konnte die demonstrierte Anwendungvon gequetschten Zustanden in Zukunft eine Unterschreitung des Standardquantenlimits ermoglichen.

•Oct 23, 2019•0 citations

An Interferometrically Robust Opto-Mechanical Coupler to Beam Polarisation

Hayat Abbas, T. Fernholz

In this work, we investigate a tool for hybrid quantum systems that implements a transducer to map small position changes of a micro-mechanical membrane onto the polarization of a laser beam. This is achieved with an interferometric setup that has reduced needs for stabilization. Specifically, an oscillating silicon nitride membrane placed in the middle of an asymmetric optical cavity causes phase shifts in the reflected, near-resonant light field. A beam displacer is used to combine the signal beam with a mode-matched, orthogonally polarized reference beam for polarization encoding. Subsequent balanced homodyne measurement is used to detect thermal membrane noise. Minor improvements in the design should achieve sufficiently high signal-to-noise ratio for the detection of motional quantum noise in the regime of high opto-mechanical coupling strength. This setup can provide a robust quantum link between a micro-mechanical oscillator and other systems such as atomic ensembles.

arXiv:2301.04577•Jan 11, 2023•0 citations

Microwave Electromechanics: Measuring and Manipulating the Quantum State of a Macroscopic Mechanical Oscillator

Jennifer Harlow

In the past several years, the field of optomechanics has progressed from proof-of-principle experiments to the realization of mechanical oscillators and measurements in the quantum regime. Mechanical oscillators are of great interest because they can have small dissipation rates, can couple to many different systems of interest, and are the fundamental elements of ultrasensitive force detectors. Coupling these mechanical oscillators to microwave or optical fields provides a twofold advantage. Firstly, information about mechanical position can be encoded in the interrogating field, enabling sensitive readout of the mechanical oscillator. Secondly, the radiation pressure force of that field can be used to control the state of the mechanical oscillator. Including a high-quality microwave or optical cavity enhances both of these effects, as the field strength is resonantly increased.\nThe major questions in the field of optomechanics in the last several years have dealt with using mechanical oscillators for ultrasensitive measurements and as tools for quantum information. Both of these goals have the prerequisite that we be able to read out the motion of the mechanical oscillator in a quantum efficient manner. To that end, we developed a nearly shot-noise limited microwave interferometer capable of measuring mechanical motion with an imprecision below that at the standard quantum limit. This achievement is not only a critical improvement for the electromechanical experiments we do, but is also an important tool for any experiment that encodes the information of interest in microwave fields. In order to use mechanical oscillators as tools for quantum information, the mechanical oscillator must also be cooled into the quantum regime and fully controllable by the interrogating fields. To this end, we used the radiation pressure of microwave fields to cool our macroscopic mechanical oscillator to less than one phonon. We also demonstrated coherent transfer between itinerant microwave states and the mechanical oscillator, even for incident fields with less than one photon of energy.\nThese accomplishments have set the foundation for further experiments to extend the quantum information abilities of optomechanical systems, couple diverse quantum systems via a mechanical intermediary, and potentially explore the foundations of quantum mechanics at macroscopic scales.

•Jan 1, 2013•4 citations

Angular displacement readout of a mechanical oscillator with a guided mode resonance

Diego Torres-Barajas, Oscar Angulo, Aman R. Agrawal +2 more

Measuring the angular displacement of a mechanical oscillator is a ubiquitous task; however, the multimode nature of angular optomechanical coupling makes coherent signal enhancement challenging. Here we demonstrate coherently enhanced angular displacement readout with an integrated guided mode resonance (GMR) structure, applying it to precision readout of a nanomechanical oscillator. Specifically, we fabricate subwavelength gratings into 100-nm-thick Si$_3$N$_4$ membranes and record their vibration by direct transmission measurements. The narrow linewidth $\approx 2.5\;\text{mrad}$ of the GMR enables a shot-noise-limited displacement imprecision of $ 10^{-9}\;\text{rad}/\sqrt{\text{Hz}}$ with nanowatts of optical power, sufficient to resolve the thermal motion of a $Q\approx 10^6$ torsion mode with a signal-to-noise ratio of 47 dB. Control experiments based on polarization and wavelength detuning confirm that the measured signal arises from GMR-mediated transduction. These results establish guided-mode resonance as an on-chip approach to angular displacement readout in quantum optomechanical sensors.

physics.opticsCross-listedarXiv:2608.14447•Aug 17, 2026

Quantum-mechanical noise in an interferometer

Carlton M. Caves

The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.

Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 15, 1981•3,277 citations
The quantum state of light changes its nature when being reflected off a mechanical oscillator due to the latter's susceptibility to radiation pressure. As a result, a coherent state can transform into a squeezed state and can get entangled with the motion of the oscillator. Full information of the state of light can only be gathered by a tomographic measurement. Here we demonstrate a tomographic interferometer readout by measuring arbitrary quadratures of the light field exiting a Michelson–Sagnac interferometer that contains a thermally excited high-quality silicon nitride membrane. A readout noise of 1.9 × 10 −16 m Hz −1/2 around the membrane's fundamental oscillation mode at 133 kHz has been achieved, going below the peak value of the standard quantum limit by a factor of 8.2 (9 dB). The readout noise was entirely dominated by shot noise in a rather broad frequency range around the mechanical resonance.
Here we report on the realization of a Michelson-Sagnac interferometer whose purpose is the precise characterization of the motion of, i.e., membranes showing significant light transmission. Our interferometer has a readout noise spectral density (imprecision) of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}\phantom{\rule{0.16em}{0ex}}\mathrm{m}/\sqrt{\mathrm{Hz}}$ at frequencies around the fundamental resonance of a SiNx{}_{\mathrm{x}}x​ membrane at about 100 kHz, without using optical cavities. The readout noise demonstrated is more than 16 dB below the peak value of the membrane's standard quantum limit (SQL). This margin is significantly bigger than those of previous works with nanowires [Teufel et al., Nature Nano. 4, 820 (2009); Anetsberger et al., Nature Phys. 5, 909 (2009)]. We discuss the meaning of the SQL for force measurements and its relation to the readout performance and emphasize that neither our nor previous experiments achieved a total noise spectral density as low as the SQL due to thermal noise.
The quantum mechanical description of electromagnetic fields predicts fluctuations in their amplitude and phase quadrature, that underlay Heisenberg's uncertainty relation. When reflected by an object, the fields induce a radiation pressure force. The amplitude uncertainty causes fluctuations of this force, resulting in quantum radiation pressure noise. The standard quantum limit sets a lower bound for the sum of radiation pressure noise and shot noise, that will dominate the sensitivity of future gravitational-wave detectors. In optomechanics the radiation pressure noise is investigated. One fundamental goal is to undercut the standard quantum limit by applying squeezed states, that have a reduced variance in one quadrature and an amplified variance in the orthogonal. A shot noise reduction of 2.2 dB in an optomechanical table top experiment can be found in the literature. In this work squeezed states were produced in a nonlinear crystal via degenerate parametric down-conversion. At a sideband frequency of 400 kHz a squeeze factor of (8.7+/-0.2) dB was measured. In a first experiment the setup was used to demonstrate how internal squeezing can improve the sensitivity of an interferometric measurement. An increase of the sensitivity-bandwidth product of 36% was experimentally observed for an artificially generated signal. This thesis further presents a cryogenic optomechanical experiment with a silicon nitride membrane as mechanical oscillator. The topology of a Michelson-Sagnac interferometer was chosen to realize a Michelson interferometer with the membrane as end mirror despite its low reflectivity. A contrast of the outcoming modes of 99.7% was reached for temperatures down to 100 K. The signal at the dark fringe allowed a measurement with a shot-noise limited sensitivity for an input power of 50 muW. After calibrating the measured spectra with the theoretical shot noise, the quality factors of the membrane Q_293=2.7*10^5 and Q_100=1,5*10^6 at 293K and 100K could be determined from the resulting displacement spectral density. By injecting externally produced squeezed states, the quantum shot noise in the presented experiment was reduced by (3.1+-0.2) dB, which corresponds to a factor of sqrt(2) in the linear displacement spectral density. For a radiation-pressure-noise limited sensitivity, the demonstrated application of squeezed states could allow to overcome the standard quantum limit in the future. Aus der quantenmechanischen Beschreibung elektromagnetischer Felder folgen Fluktuationen in deren Amplituden- und Phasenquadratur, die der Heisenbergsche Unscharferelation unterliegen. Wenn die Felder von einem Objekt reflektiert werden, erzeugen sie eine Strahlungsdruckkraft. Die Fluktuationen dieser Kraft aufgrund der Amplitudenunscharfe verursachen das Quanten-Strahlungsdruckrauschen. Das Standardquantenlimit ist der Minimalwert fur die Summe aus Strahlungsdruckrauschen und Schrotrauschen, der in Zukunft die Sensitivitat von Gravitationswellendetektoren limitieren wird. In der Optomechanik wird das Strahlungsdruckrauschen erforscht. Ein fundamentales Ziel ist das Uberwinden des Standardquantenlimits durch die Anwendung gequetschter Zustande, deren Varianz in einer Quadratur vermindert aber in der orthogonalen erhoht ist. In der Literatur findet man eine Schrotrauschreduktion von 2.2 dB in einem optomechanischem Tischaufbau. In dieser Arbeit wurden gequetschte Zustande mithilfe der parametrischen Abkonversion in einem nichtlinearen Kristall generiert. Bei einer Seitenbandfrequenz von 400 kHz wurde ein Quetschfaktor von (8.7+-0.2) dB gemessen. In einem ersten Experiment mit dem Aufbau wurde demonstriert, wie intern produzierte gequetschte Zustande die Sensitivitat einer interferometrischen Messung verbessern konnen. Ein Anstieg des Sensitivitat-Bandbreite-Produkts von 36% wurde fur ein kunstlich generiertes Signal experimentell beobachtet. Es wird weiterhin ein kryogenes optomechanisches Experiment mit einer Siliziumnitrid-Membran als mechanischer Oszillator prasentiert. Die Topologie des Michelson-Sagnac-Interferometers wurde gewahlt um trotz ihrer geringen Reflektivitat ein Michelson-Interferometer mit der Membran als Endspiegel zu realisieren. Fur Temperaturen bis minimal 100K konnte ein Kontrast der Moden im Ausgang von 99.7% erreicht werden. Das Signal im dunklen Ausgang ermoglichte eine Messung mit einer vom Schrotrauschen limitierten Sensitivitat fur eine Eingangsleistung von 50 muW. Nach der Kalibrierung der gemessenen Spektren mit dem theoretischen Schrotrauschen konnten die Gutefaktoren der Membran Q_293=2.7*10^5 und Q_100=1.5*10^6 bei 293K und 100K aus der resultierenden spektrale Dichte der Ortsanderung bestimmt werden. Durch die Injektion extern produzierter gequetschter Zustande wurde das Quantenschrotrauschen im prasentierten Experiment um (3.1 +/-0.2) dB gesenkt, was einem Faktor Wurzel(2) in der linearen spektralen Rauschdichte entspricht. Fur eine vom Strahlungsdruckrauschen limitierte Sensitivitat konnte die demonstrierte Anwendungvon gequetschten Zustanden in Zukunft eine Unterschreitung des Standardquantenlimits ermoglichen.
In this work, we investigate a tool for hybrid quantum systems that implements a transducer to map small position changes of a micro-mechanical membrane onto the polarization of a laser beam. This is achieved with an interferometric setup that has reduced needs for stabilization. Specifically, an oscillating silicon nitride membrane placed in the middle of an asymmetric optical cavity causes phase shifts in the reflected, near-resonant light field. A beam displacer is used to combine the signal beam with a mode-matched, orthogonally polarized reference beam for polarization encoding. Subsequent balanced homodyne measurement is used to detect thermal membrane noise. Minor improvements in the design should achieve sufficiently high signal-to-noise ratio for the detection of motional quantum noise in the regime of high opto-mechanical coupling strength. This setup can provide a robust quantum link between a micro-mechanical oscillator and other systems such as atomic ensembles.
In the past several years, the field of optomechanics has progressed from proof-of-principle experiments to the realization of mechanical oscillators and measurements in the quantum regime. Mechanical oscillators are of great interest because they can have small dissipation rates, can couple to many different systems of interest, and are the fundamental elements of ultrasensitive force detectors. Coupling these mechanical oscillators to microwave or optical fields provides a twofold advantage. Firstly, information about mechanical position can be encoded in the interrogating field, enabling sensitive readout of the mechanical oscillator. Secondly, the radiation pressure force of that field can be used to control the state of the mechanical oscillator. Including a high-quality microwave or optical cavity enhances both of these effects, as the field strength is resonantly increased.\nThe major questions in the field of optomechanics in the last several years have dealt with using mechanical oscillators for ultrasensitive measurements and as tools for quantum information. Both of these goals have the prerequisite that we be able to read out the motion of the mechanical oscillator in a quantum efficient manner. To that end, we developed a nearly shot-noise limited microwave interferometer capable of measuring mechanical motion with an imprecision below that at the standard quantum limit. This achievement is not only a critical improvement for the electromechanical experiments we do, but is also an important tool for any experiment that encodes the information of interest in microwave fields. In order to use mechanical oscillators as tools for quantum information, the mechanical oscillator must also be cooled into the quantum regime and fully controllable by the interrogating fields. To this end, we used the radiation pressure of microwave fields to cool our macroscopic mechanical oscillator to less than one phonon. We also demonstrated coherent transfer between itinerant microwave states and the mechanical oscillator, even for incident fields with less than one photon of energy.\nThese accomplishments have set the foundation for further experiments to extend the quantum information abilities of optomechanical systems, couple diverse quantum systems via a mechanical intermediary, and potentially explore the foundations of quantum mechanics at macroscopic scales.
Measuring the angular displacement of a mechanical oscillator is a ubiquitous task; however, the multimode nature of angular optomechanical coupling makes coherent signal enhancement challenging. Here we demonstrate coherently enhanced angular displacement readout with an integrated guided mode resonance (GMR) structure, applying it to precision readout of a nanomechanical oscillator. Specifically, we fabricate subwavelength gratings into 100-nm-thick Si3_33​N4_44​ membranes and record their vibration by direct transmission measurements. The narrow linewidth ≈2.5  mrad\approx 2.5\;\text{mrad}≈2.5mrad of the GMR enables a shot-noise-limited displacement imprecision of $ 10^{-9}\;\text{rad}/\sqrt{\text{Hz}}$ with nanowatts of optical power, sufficient to resolve the thermal motion of a Q≈106Q\approx 10^6Q≈106 torsion mode with a signal-to-noise ratio of 47 dB. Control experiments based on polarization and wavelength detuning confirm that the measured signal arises from GMR-mediated transduction. These results establish guided-mode resonance as an on-chip approach to angular displacement readout in quantum optomechanical sensors.
The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique---the "squeezed-state" technique---that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"---a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.