Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1204.4385 · Chinese Science Bulletin

Active optical clock based on four-level quantum system

TongGang Zhang, YanFei Wang, Xiaorun Zang, Wei Zhuang, Jingbiao Chen

Published Jun 1, 2013• 43 citations
arXivHTMLPDF
DOI
10.1007/s11434-013-5877-0

Related papers

Active optical clock

Jingbiao Chen

中国科学通报:英文版•Feb 1, 2009•165 citations

An Active Ion Optical Clock

庄伟, 张同刚, Jingbiao Chen

Chinese Physics Letters•Jan 1, 2014•0 citations

A Potassium Atom Four-Level Active Optical Clock Scheme

Shengnan Zhang, Yanfei Wang, Tong-Gang Zhang +2 more

We present an active optical clock scheme with a four-level quantum potassium system. We calculate the population probabilities of each state using the density matrix. At the steady state, ρ 33 and ρ 55 are equal to 8.3% and 3.5%, respectively, and the population inversion between the 5S 1/2 and 4P 3/2 states is built up in the thermal potassium cell with a 404.7 nm pumping laser. According to the mechanism of the active optical clock, under the action of the 404.7 nm pumping laser, the scheme can output a 1252.2 nm quantum-limited-linewidth laser, which can be directly used as an active optical frequency standard.

Chinese Physics Letters•Apr 1, 2013•21 citations

Quantum enhanced optical atomic clock

Chi Shu, Edwin Pedrozo-Peñafiel, Simone Colombo +4 more

Bulletin of the American Physical Society•Jun 1, 2021•0 citations

Dual-wavelength active optical clock

Zhichao Xu, Duo Pan, Wei Zhuang +1 more

We experimentally realize the dual-wavelength active optical clock for the first time. As the Cs cell temperature is kept between 118 $^{\circ }C$ and 144 $^{\circ }C$, both the 1359 nm and the 1470 nm stimulated emission output of Cs four-level active optical clock are detected. The 1470 nm output linewidth of each experimental setup of Cs four-level active optical clock is measured to be 590 Hz with the main cavity length unstabilized. To stabilize the cavity length of active optical clock, the experimental scheme of 633 nm and 1359 nm good-bad cavity dual-wavelength active optical clock is proposed, where 633 nm and 1359 nm stimulated emission is working at good-cavity and bad-cavity regime respectively. The cavity length is stabilized by locking the 633 nm output frequency to a super-cavity with the Pound-Drever-Hall (PDH) technique. The frequency stability of 1359 nm bad-cavity stimulated emission output is then expected to be further improved by at least 1 order of magnitude than the 633 nm PDH system due to the suppressed cavity pulling effect of active optical clock, and the quantum limited linewidth of 1359 nm output is estimated to be 77.6 mHz.

arXiv:1407.1505•Jul 6, 2014•2 citations

Quantum engineering for optical clocks

Christian Lisdat, Carsten Klempt

Nature•Dec 16, 2020•3 citations
We present an active optical clock scheme with a four-level quantum potassium system. We calculate the population probabilities of each state using the density matrix. At the steady state, ρ 33 and ρ 55 are equal to 8.3% and 3.5%, respectively, and the population inversion between the 5S 1/2 and 4P 3/2 states is built up in the thermal potassium cell with a 404.7 nm pumping laser. According to the mechanism of the active optical clock, under the action of the 404.7 nm pumping laser, the scheme can output a 1252.2 nm quantum-limited-linewidth laser, which can be directly used as an active optical frequency standard.
We experimentally realize the dual-wavelength active optical clock for the first time. As the Cs cell temperature is kept between 118 ∘C^{\circ }C∘C and 144 ∘C^{\circ }C∘C, both the 1359 nm and the 1470 nm stimulated emission output of Cs four-level active optical clock are detected. The 1470 nm output linewidth of each experimental setup of Cs four-level active optical clock is measured to be 590 Hz with the main cavity length unstabilized. To stabilize the cavity length of active optical clock, the experimental scheme of 633 nm and 1359 nm good-bad cavity dual-wavelength active optical clock is proposed, where 633 nm and 1359 nm stimulated emission is working at good-cavity and bad-cavity regime respectively. The cavity length is stabilized by locking the 633 nm output frequency to a super-cavity with the Pound-Drever-Hall (PDH) technique. The frequency stability of 1359 nm bad-cavity stimulated emission output is then expected to be further improved by at least 1 order of magnitude than the 633 nm PDH system due to the suppressed cavity pulling effect of active optical clock, and the quantum limited linewidth of 1359 nm output is estimated to be 77.6 mHz.