We perform a high-resolution real-time readout of the motion of a single trapped and laser-cooled Ba+ ion. By using an interferometric setup, we demonstrate a shot-noise-limited measurement of thermal oscillations with a resolution of 4 times the standard quantum limit. We apply the real-time monitoring for phase control of the ion motion through a feedback loop, suppressing the photon recoil-induced phase diffusion. Because of the spectral narrowing in the phase-locked mode, the coherent ion oscillation is measured with a resolution of about 0.3 times the standard quantum limit.
We perform a high-resolution real-time readout of the motion of a single trapped and laser-cooled Ba+ ion. By using an interferometric setup, we demonstrate a shot-noise-limited measurement of thermal oscillations with a resolution of 4 times the standard quantum limit. We apply the real-time monitoring for phase control of the ion motion through a feedback loop, suppressing the photon recoil-induced phase diffusion. Because of the spectral narrowing in the phase-locked mode, the coherent ion oscillation is measured with a resolution of about 0.3 times the standard quantum limit.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.
Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A 49pm displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an 8.4pm/Hz displacement sensitivity is achieved, which implies 12(yN/ion)/Hz and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and 1nV/m, respectively.
A single trapped ion, laser cooled into its quantum ground state of motion, may be used as a very-low-temperature detector of radio-frequency signals applied to the trap end caps. If the signal source is a resonant oscillator of sufficiently high Q, the source may also be placed in its quantum ground state by coupling to the ion. Parametric couplings may be used to cool and detect source modes other than the mode directly coupled to the ion. A theoretical analysis of these cooling and detection processes is presented, and as an example, their application to single trapped electron and proton spectroscopy is examined. Squeezing and low noise detection of one quadrature component of the source oscillation are also discussed. The techniques discussed here may lead to radio-frequency measurements of improved accuracy and sensitivity. Cooling and detection of vibrations of macroscopic oscillators also appear possible.
A trapped-ion harmonic oscillator represents a rich and well-controlled platform for tests of quantum physics, with applications to quantum simulations, quantum sensing, and quantum information processing. Owing to its net charge, the ion's motion is affected by changes in the electric potential. Consequently, electric field and potential curvature noise will limit the coherence of the ion's harmonic oscillation. While in some respects, this serves as a limitation in the performance of the trapped ion system (for example, in the fidelity of two-qubit gates or quantum simulations with motional quanta), it also opens an opportunity to use the ion as a precise field sensor and to use engineered quantum states of motion to enhance the sensitivity to these fields beyond the standard quantum limit (SQL). This thesis describes the implementation of such applications on a single beryllium ion confined in a Paul trap. In the thesis, I present the theory of an ideal harmonic oscillator and the implementation of this system using the motion of a single trapped ion, including producing special quantum states of motion; these states include the energy eigenstates of the harmonic oscillator, called number states, up to n=100, superpositions of number states of the form (1/√2)(|0> + |n>), with n up to 18, and coherently displaced number states with an average occupation up to approximately 300. I describe how we use these quantum states of motion for precise sensing of fluctuations of the harmonic oscillator frequency. The sensitivity of the (1/√2)(|0> + |n>) state ideally follows the 1/n Heisenberg scaling for frequency sensitivity. Additionally, I describe investigations of the spectrum of motional frequency noise using a series of coherent displacements of the motion of the ion, with features similar to Ramsey and dynamical decoupling sequences for two-level systems. While these displaced states don't improve sensitivity over the SQL, they can be simply and rapidly implemented with trapped ions. I discuss extensions to all of these experiments, including to multiple ions in a new trap designed to confine 3 or 4 ions in individually tunable potential wells.
We discuss continuous observation of the momentum of a single atom by employing the high velocity sensitivity of the index of refraction in a driven $\ensuremath{\Lambda}$-system based on electromagnetically induced transparency. In the ideal limit of unit collection efficiency this provides a quantum-limited measurement with minimal backaction on the atomic motion. A feedback loop, which drives the atom with a force proportional to measured signal, provides a cooling mechanism for the atomic motion. We derive the master equation which describes the feedback cooling and show that in the Lamb-Dicke limit the steady state energies are close to the ground state, limited only by the photon collection efficiency. Outside of the Lamb-Dicke regime the predicted temperatures are well below the Doppler limit.
Characterization of noise of a quantum harmonic oscillator is important for many experimental platforms. We experimentally demonstrate motional spin-locking spectroscopy, a method that allows us to directly measure the motional noise spectrum of a quantum harmonic oscillator. We measure motional noise of a single trapped ion in a frequency range from 200 Hz to 5 kHz with a power spectral density that resolves noise over two orders of magnitude. Coherent modulations in the oscillation frequency of the oscillator can be probed with a relative frequency sensitivity at the 10−6 level.