Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1112.0866 · Physica Scripta

Peak doubling in spontaneous parametric down-conversion coincidence spectra with a short-pulse pump*

Mikhail Vladimirovich Fedorov, J. M. Mikhailova, P. A. Volkov

Published Apr 20, 2012• 1 citation
arXivHTMLPDF

Abstract

We describe a double-peak structure of the coincidence spectrum of biphoton states in the process of spontaneous parametric down-conversion with a pump having the form of short pulses. The effect is shown to arise owing to the obligatory symmetry of bihoton wave functions, as wave functions describing states of two bozons obeying the Bose-Einstein statistics. Parameters of the peaks are found and conditions necessary for experimental observation of the effect are determined.

DOI
10.1088/0031-8949/85/05/058105

Related papers

Experimental observation of double-peak structure of coincidence spectra in ultrafast spontaneous parametric down-conversion

Dmitry A. Kalashnikov, Mikhail Vladimirovich Fedorov, Leonid A. Krivitsky

The requirement for symmetry of the biphoton wave function results in a double-peak structure of the coincidence spectra of spontaneous parametric down-conversion (SPDC) [Fedorov, Mikhailova, and Volkov, Phys. Scr. 85, 058105 (2012)]. In this work we report the experimental observation of this effect by carefully tailoring parameters of the SPDC crystal, the ultrafast pump laser, and the measurement setup. The results are shown to be relevant to quantum state engineering of ultrafast polarization or frequency-entangled mixed states.

arXiv:1209.4686•Physical Review A•Jan 2, 2013•3 citations

Biphoton wave packets in parametric down-conversion: Spectral and temporal structure and degree of entanglement

J. M. Mikhailova, P. A. Volkov, Mikhail Vladimirovich Fedorov

We investigate spectral and temporal features and entanglement of biphoton wave packets formed in spontaneous parametric down-conversion with a pulsed laser pump. The degree of entanglement is characterized by the experimentally measurable parameter $R$ defined as the ratio of the coincidence and single-particle spectral widths. In the frequency representation, this parameter is found as a function of the pump-pulse duration $\ensuremath{\tau}$. The function $R(\ensuremath{\tau})$ is shown to have a minimum and even in the minimum, at rather natural conditions, the degree of entanglement is found to be very high $({R}_{\mathrm{min}}=73)$. The Schmidt number $K$ is found analytically for both short and long pump pulses and interpolated for arbitrary pulse durations. All functional dependences of $R$ and $K$ are found to be identical and numerical coefficients are found to be rather close. Two-time temporal wave function of a biphoton state is investigated in detail, and a rather significant difference between the cases of short and long pump pulses is found to occur. In the case of long pulses, the temporal parameter ${R}_{t}$ (defined as the ratio of durations of the single-particle and coincidence signals) is shown to be very close to the Schmidt number $K$.

arXiv:0801.0689•Physical Review A•Dec 16, 2008•101 citations

Gaussian modelling and Schmidt modes of SPDC biphoton states

Mikhail Vladimirovich Fedorov, J. M. Mikhailova, P. A. Volkov

A double-Gaussian model and the Schmidt modes are found for the biphoton wave function characterizing spontaneous parametric down-conversion with the degenerate collinear phase-matching of the type I and with a pulsed pump. The obtained results are valid for all durations of the pump pulses, short, long and intermediately long.

arXiv:0906.3273•Journal of Physics B Atomic Molecular and Optical Physics•Aug 12, 2009•76 citations

Interferometric signature of different spectral symmetries of biphoton states

Nicolas Fabre

In this paper, we investigate the influence of the symmetry of the biphoton wave function on the coincidence measurement of the generalized Mach-Zehnder (MZ) interferometer, where there are a temporal and frequency shift operations between the two beam splitters. We show that the generalized MZ interferometer allows the measurement of the short-time Fourier transform of the function modeling the energy conservation of a spontaneous parametric down-conversion process if the full biphoton state is symmetric, and of the symmetric characteristic distribution of the phase-matching function if the state is antisymmetric. Thus, this technique is phase sensitive to the spectral distribution of the photon pairs. Finally, we investigate in detail the signature of a pair of anyons whose peculiar statistics can be simulated by engineering the spectrum of photon pairs.

arXiv:2112.09610•Physical Review A•May 20, 2022•6 citations

Spectral Characterisation of Spontaneous Parametric-Down Conversion Entangled Photons Source in Femtosecond Pulsed Regime

G. Brida, Valentina Caricato, Marco Genovese +4 more

We report on experimental measurements of coincidence and single particle spectral shapes of biphoton signals when frequency entangled states are generated by SPDC crystals pumped by short pulses.It is shown evidence for biphoton coincidence spectrum narrower and single-particle one wider than the pump spectrum, with a large contrast between coincidence and singles distributions.The investigation of biphoton correlations has been performed by fixing one monochromator at the maximal transmission wavelength on down-converted signal gate and scanning the one placed in the idler branch in order to observe the spectral distribution of single counts and coincidences.The degree of entanglement is evaluated by the ratio of the FWHM of single particle and coincidence distributions: the greater the ratio, the greater is the entanglement.The degree of entanglement in frequency variables can be very high: it increases linearly with the length of the crystal, and decreases with the growing pump pulse.

International Conference on Quantum, Nano and Micro Technologies (ICQNM)•Feb 1, 2009•0 citations

Carrier-envelope-phase Dependence in Spontaneous Parametric Down-Conversion

Sanjit Karmakar, Chen-Ting Liao

The influence of the carrier-envelope phase of a femtosecond pump laser pulse on spontaneous parametric down-conversion is investigated. We show that the coincidence rates and joint spectrum intensity of the generated entangled biphotons are modified.

Conference on Lasers and Electro-Optics•Jan 1, 2026•0 citations
We describe a double-peak structure of the coincidence spectrum of biphoton states in the process of spontaneous parametric down-conversion with a pump having the form of short pulses. The effect is shown to arise owing to the obligatory symmetry of bihoton wave functions, as wave functions describing states of two bozons obeying the Bose-Einstein statistics. Parameters of the peaks are found and conditions necessary for experimental observation of the effect are determined.
The requirement for symmetry of the biphoton wave function results in a double-peak structure of the coincidence spectra of spontaneous parametric down-conversion (SPDC) [Fedorov, Mikhailova, and Volkov, Phys. Scr. 85, 058105 (2012)]. In this work we report the experimental observation of this effect by carefully tailoring parameters of the SPDC crystal, the ultrafast pump laser, and the measurement setup. The results are shown to be relevant to quantum state engineering of ultrafast polarization or frequency-entangled mixed states.
We investigate spectral and temporal features and entanglement of biphoton wave packets formed in spontaneous parametric down-conversion with a pulsed laser pump. The degree of entanglement is characterized by the experimentally measurable parameter RRR defined as the ratio of the coincidence and single-particle spectral widths. In the frequency representation, this parameter is found as a function of the pump-pulse duration $\ensuremath{\tau}$. The function $R(\ensuremath{\tau})$ is shown to have a minimum and even in the minimum, at rather natural conditions, the degree of entanglement is found to be very high (Rmin=73)({R}_{\mathrm{min}}=73)(Rmin​=73). The Schmidt number KKK is found analytically for both short and long pump pulses and interpolated for arbitrary pulse durations. All functional dependences of RRR and KKK are found to be identical and numerical coefficients are found to be rather close. Two-time temporal wave function of a biphoton state is investigated in detail, and a rather significant difference between the cases of short and long pump pulses is found to occur. In the case of long pulses, the temporal parameter Rt{R}_{t}Rt​ (defined as the ratio of durations of the single-particle and coincidence signals) is shown to be very close to the Schmidt number KKK.
In this paper, we investigate the influence of the symmetry of the biphoton wave function on the coincidence measurement of the generalized Mach-Zehnder (MZ) interferometer, where there are a temporal and frequency shift operations between the two beam splitters. We show that the generalized MZ interferometer allows the measurement of the short-time Fourier transform of the function modeling the energy conservation of a spontaneous parametric down-conversion process if the full biphoton state is symmetric, and of the symmetric characteristic distribution of the phase-matching function if the state is antisymmetric. Thus, this technique is phase sensitive to the spectral distribution of the photon pairs. Finally, we investigate in detail the signature of a pair of anyons whose peculiar statistics can be simulated by engineering the spectrum of photon pairs.
We report on experimental measurements of coincidence and single particle spectral shapes of biphoton signals when frequency entangled states are generated by SPDC crystals pumped by short pulses.It is shown evidence for biphoton coincidence spectrum narrower and single-particle one wider than the pump spectrum, with a large contrast between coincidence and singles distributions.The investigation of biphoton correlations has been performed by fixing one monochromator at the maximal transmission wavelength on down-converted signal gate and scanning the one placed in the idler branch in order to observe the spectral distribution of single counts and coincidences.The degree of entanglement is evaluated by the ratio of the FWHM of single particle and coincidence distributions: the greater the ratio, the greater is the entanglement.The degree of entanglement in frequency variables can be very high: it increases linearly with the length of the crystal, and decreases with the growing pump pulse.