arXiv:1106.2771 · New Journal of Physics

Weighing of trapped ion crystals and its applications

Kevin Sheridan, Matthias Keller

Published Dec 1, 2011• 17 citations
arXivHTMLPDF

Abstract

We have developed a novel scheme to measure the secular motion of trapped ions. Employing pulsed excitation and analysis of the fluorescence of laser-cooled ions, we have measured the centre-of-mass mode frequency of single as well as entire ion crystals with a frequency precision better than 5 × 10 −4 within an interrogation time on the order of seconds, limited only by the fluorescence collection efficiency and the background noise. We have used this method to measure the mass of ions and observed charge exchange collisions between trapped calcium isotopes.

DOI
10.1088/1367-2630/13/12/123002

Related papers

Experimental techniques for cold chemistry and molecular spectroscopy in an ion trap

Kevin Sheridan

A range of experimental techniques for application in reaction studies between ionic and neutral atoms/molecules and high resolution spectroscopy experiments with sympathetically cooled molecular ions are presented. A novel ion trap loading scheme using the photo-ionisation of atoms generated by the pulsed laser ablation of a solid calcium target has been characterised. We have identified the range of ablation laser fluences that must be used in order to produce a flux of neutral calcium atoms, which is a prerequisite for isotope selective ion trap loading. Calcium ions are trapped and laser cooled in a linear radio-frequency ion trap. We have developed a spectroscopy scheme that allows the entire fluorescence spectrum of trapped ions to be rapidly collected with high precision while maintaining a low ion temperature and good ion localisation throughout interrogation. The scheme has been demonstrated by measuring the saturation intensity of the calcium ion 4S1/2?4P1/2 transition. We have developed a novel scheme to measure the secular motion of trapped ions and demonstrated the application of the technique to ion-neutral collision reaction experiments. Employing pulsed excitation and Doppler velocimetry, we have measured the centre-of-mass mode frequency of single ions as well as large ion crystals with a frequency precision better than 2x10-3 within an interrogation time on the order of seconds. This method has been used to measure the mass of ions and observe charge exchange collisions between trapped calcium isotopes. In particular, we have measured the 44Ca++40Ca!40Ca++44Ca reaction cross section and demonstrated the single-event resolution of the technique. Finally, we have developed a novel all-optical broadband scheme for exciting, amplifying and measuring the secular motion of ions in the trap. Oscillation induced by optical excitation has been coherently amplified to control and measure the ion's secular motion. Requiring only a single interrogation laser, the ion's oscillation amplitude can be precisely controlled. The application of this technique to non-destructive spectroscopy of trapped molecular ions is discussed.

•Oct 3, 2013•0 citations

Monitoring a single ion's motion by second-order photon correlations

D. Rotter, Manas Mukherjee, François Dubin +1 more

For a single trapped ion, second-order time correlations of fluorescence photons are measured in a self-homodyne configuration by beating the fluorescence with itself. At the nanosecond timescale, the correlations are governed by electronic excitation and decay of the ion and anti-bunching in the resonance fluorescence is observed and quantitatively reproduced. On the other hand, at the microsecond timescale the motion of the ion determines the correlations: secular motional modes, their amplitude and relative coherence are measured. Besides precisely monitoring the trap frequencies, our observations also quantify the temporal stability of the trapping potential.

New Journal of Physics•Apr 10, 2008•18 citations

Ion trap frequency measurement from fluorescence dynamics

Kota Saito, Ryoichi Saito, Takashi Mukaiyama

In this paper, we propose and demonstrate a new method for measuring the trap frequency from the fluorescence dynamics of an ion, initiated using fast trap-center displacement. Here, we observe the coherently excited motion of an ion in a harmonic trap using time-resolved fluorescence detection. Furthermore, Fourier analysis of the ion fluorescence signal was used to determine the trap frequency of an ion with high precision and reproducibility. The results show that our proposed method can be an alternative way to determine trap frequencies in an ion trap experiment.

Journal of Applied Physics•Sep 1, 2022•4 citations

Phase-coherent sensing of the center-of-mass motion of trapped-ion crystals

M. Affolter, Kevin Gilmore, J. E. Jordan +1 more

Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A $49\phantom{\rule{4pt}{0ex}}\mathrm{pm}$ displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an $8.4\phantom{\rule{4pt}{0ex}}\mathrm{pm}/\sqrt{\mathrm{Hz}}$ displacement sensitivity is achieved, which implies $12\phantom{\rule{0.16em}{0ex}}(\mathrm{yN}/\mathrm{ion})/\sqrt{\mathrm{Hz}}$ and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and $1\phantom{\rule{4pt}{0ex}}\mathrm{nV}$/m, respectively.

arXiv:2008.00035•Physical Review A•Nov 9, 2020•28 citations

Classical mode dynamics for trapped ion diagnostics

Itzal D. U. Terrazas, DanielF.V. James

In this paper we consider two problems in diagnostics of trapped ion crystals in which an analysis of the ions' collective oscillatory motion yield potentially useful results. When one of the ions in a linear crystal undergoes a collision, observation of the subsequent motion allows one to deduce the identity of which ion sustained the collision. When a linear ion crystal is formed with a dark impurity ion, analysis of the ions' motion can identify the mass (and thus give an important clue to the species) of the impurity.

arXiv:2212.02722•Journal of Modern Optics•Oct 23, 2024•0 citations

Resolved Sideband Spectroscopy for the Detection of Weak Optical Transitions

James E. Goeders

This thesis reports on the setup of a new ion trap apparatus designed for experiments with single ⁴⁰Ca⁺ ions to perform molecular spectroscopy. The calcium ion is laser cooled, allowing for sympathetic cooling of the nonfluorescing molecular ion. The aim of these experiments is to explore loading and identifying molecular ions in RF-Paul traps, as well as developing new spectroscopic tools to measure transitions of molecular ions via the fluorescence of co-trapped ⁴⁰Ca⁺ ions. Ground state cooling of a mixed ion pair is implemented as a first step towards increasing the sensitivity of our technique to the level necessary to measure transitions with low scattering rates (like those present in molecular ions). Doppler cooling on the S(1/2)->P(1/2) transition of the calcium ion results in the formation of a Coulomb crystal, the behavior of which may be used to infer properties of the molecular ion. Following cooling, sideband spectroscopy on the narrow S(1/2)->D(5/2) quadrupole transition of calcium may be used to identify the mass of single molecular ions. This method is verified via a non-destructive measurement on ⁴⁰CaH⁺ and ⁴⁰Ca¹⁶O⁺. The normal modes of the Coulomb crystal can also be used to extract information from the target ion to the control ion. By driving the blue side of a transition, laser induced heating can be put into the two ion system, which leads to changes in fluorescence of the ⁴⁰Ca⁺ ion, first demonstrated with two Ca⁺ isotopes. Increasing the sensitivity of this technique requires ground state cooling of both the ⁴⁰Ca⁺ ion and the ion of interest, enabling the transfer of the ion's motional state into the ground state with high probability. This thesis demonstrates ground state cooling of the atomic ion and sympathetic cooling of a second ion (⁴⁴Ca⁺). Once in the ground state, heating of the Coulomb crystal by scattering photons off of the spectroscopy ion can be measured by monitoring the resolved motional sidebands of the S(1/2)->D(5/2) transition of ⁴⁰Ca⁺, allowing for spectral lines to be inferred. Future experiments will investigate this technique with molecular ions.

•Jul 2, 2013•2 citations
We have developed a novel scheme to measure the secular motion of trapped ions. Employing pulsed excitation and analysis of the fluorescence of laser-cooled ions, we have measured the centre-of-mass mode frequency of single as well as entire ion crystals with a frequency precision better than 5 × 10 −4 within an interrogation time on the order of seconds, limited only by the fluorescence collection efficiency and the background noise. We have used this method to measure the mass of ions and observed charge exchange collisions between trapped calcium isotopes.
A range of experimental techniques for application in reaction studies between ionic and neutral atoms/molecules and high resolution spectroscopy experiments with sympathetically cooled molecular ions are presented. A novel ion trap loading scheme using the photo-ionisation of atoms generated by the pulsed laser ablation of a solid calcium target has been characterised. We have identified the range of ablation laser fluences that must be used in order to produce a flux of neutral calcium atoms, which is a prerequisite for isotope selective ion trap loading. Calcium ions are trapped and laser cooled in a linear radio-frequency ion trap. We have developed a spectroscopy scheme that allows the entire fluorescence spectrum of trapped ions to be rapidly collected with high precision while maintaining a low ion temperature and good ion localisation throughout interrogation. The scheme has been demonstrated by measuring the saturation intensity of the calcium ion 4S1/2?4P1/2 transition. We have developed a novel scheme to measure the secular motion of trapped ions and demonstrated the application of the technique to ion-neutral collision reaction experiments. Employing pulsed excitation and Doppler velocimetry, we have measured the centre-of-mass mode frequency of single ions as well as large ion crystals with a frequency precision better than 2x10-3 within an interrogation time on the order of seconds. This method has been used to measure the mass of ions and observe charge exchange collisions between trapped calcium isotopes. In particular, we have measured the 44Ca++40Ca!40Ca++44Ca reaction cross section and demonstrated the single-event resolution of the technique. Finally, we have developed a novel all-optical broadband scheme for exciting, amplifying and measuring the secular motion of ions in the trap. Oscillation induced by optical excitation has been coherently amplified to control and measure the ion's secular motion. Requiring only a single interrogation laser, the ion's oscillation amplitude can be precisely controlled. The application of this technique to non-destructive spectroscopy of trapped molecular ions is discussed.
For a single trapped ion, second-order time correlations of fluorescence photons are measured in a self-homodyne configuration by beating the fluorescence with itself. At the nanosecond timescale, the correlations are governed by electronic excitation and decay of the ion and anti-bunching in the resonance fluorescence is observed and quantitatively reproduced. On the other hand, at the microsecond timescale the motion of the ion determines the correlations: secular motional modes, their amplitude and relative coherence are measured. Besides precisely monitoring the trap frequencies, our observations also quantify the temporal stability of the trapping potential.
In this paper, we propose and demonstrate a new method for measuring the trap frequency from the fluorescence dynamics of an ion, initiated using fast trap-center displacement. Here, we observe the coherently excited motion of an ion in a harmonic trap using time-resolved fluorescence detection. Furthermore, Fourier analysis of the ion fluorescence signal was used to determine the trap frequency of an ion with high precision and reproducibility. The results show that our proposed method can be an alternative way to determine trap frequencies in an ion trap experiment.
Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A 49pm49\phantom{\rule{4pt}{0ex}}\mathrm{pm}49pm displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an 8.4pm/Hz8.4\phantom{\rule{4pt}{0ex}}\mathrm{pm}/\sqrt{\mathrm{Hz}}8.4pm/Hz​ displacement sensitivity is achieved, which implies 12(yN/ion)/Hz12\phantom{\rule{0.16em}{0ex}}(\mathrm{yN}/\mathrm{ion})/\sqrt{\mathrm{Hz}}12(yN/ion)/Hz​ and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and 1nV1\phantom{\rule{4pt}{0ex}}\mathrm{nV}1nV/m, respectively.
In this paper we consider two problems in diagnostics of trapped ion crystals in which an analysis of the ions' collective oscillatory motion yield potentially useful results. When one of the ions in a linear crystal undergoes a collision, observation of the subsequent motion allows one to deduce the identity of which ion sustained the collision. When a linear ion crystal is formed with a dark impurity ion, analysis of the ions' motion can identify the mass (and thus give an important clue to the species) of the impurity.
This thesis reports on the setup of a new ion trap apparatus designed for experiments with single ⁴⁰Ca⁺ ions to perform molecular spectroscopy. The calcium ion is laser cooled, allowing for sympathetic cooling of the nonfluorescing molecular ion. The aim of these experiments is to explore loading and identifying molecular ions in RF-Paul traps, as well as developing new spectroscopic tools to measure transitions of molecular ions via the fluorescence of co-trapped ⁴⁰Ca⁺ ions. Ground state cooling of a mixed ion pair is implemented as a first step towards increasing the sensitivity of our technique to the level necessary to measure transitions with low scattering rates (like those present in molecular ions). Doppler cooling on the S(1/2)->P(1/2) transition of the calcium ion results in the formation of a Coulomb crystal, the behavior of which may be used to infer properties of the molecular ion. Following cooling, sideband spectroscopy on the narrow S(1/2)->D(5/2) quadrupole transition of calcium may be used to identify the mass of single molecular ions. This method is verified via a non-destructive measurement on ⁴⁰CaH⁺ and ⁴⁰Ca¹⁶O⁺. The normal modes of the Coulomb crystal can also be used to extract information from the target ion to the control ion. By driving the blue side of a transition, laser induced heating can be put into the two ion system, which leads to changes in fluorescence of the ⁴⁰Ca⁺ ion, first demonstrated with two Ca⁺ isotopes. Increasing the sensitivity of this technique requires ground state cooling of both the ⁴⁰Ca⁺ ion and the ion of interest, enabling the transfer of the ion's motional state into the ground state with high probability. This thesis demonstrates ground state cooling of the atomic ion and sympathetic cooling of a second ion (⁴⁴Ca⁺). Once in the ground state, heating of the Coulomb crystal by scattering photons off of the spectroscopy ion can be measured by monitoring the resolved motional sidebands of the S(1/2)->D(5/2) transition of ⁴⁰Ca⁺, allowing for spectral lines to be inferred. Future experiments will investigate this technique with molecular ions.