Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1103.2253 · Physical Review A

Single ion as a shot-noise-limited magnetic-field-gradient probe

Andreas Walther, Ulrich Poschinger, Frank Ziesel, M. Hettrich, A. Wiens, Joachim Welzel, Ferdinand Schmidt‐Kaler

Published Jun 23, 2011• 9 citations
arXivHTMLPDF

Abstract

It is expected that ion-trap quantum computing can be made scalable through protocols that make use of transport of ion qubits between subregions within the ion trap. In this scenario, any magnetic field inhomogeneity the ion experiences during the transport may lead to dephasing and loss of fidelity. Here we demonstrate how to measure, and compensate for, magnetic field gradients inside a segmented ion trap, by transporting a single ion over variable distances. We attain a relative magnetic field sensitivity of $\ensuremath{\Delta}B/{B}_{0}~5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}$ over a test distance of 140 $\ensuremath{\mu}$m, which can be extended to the mm range, still with sub-$\ensuremath{\mu}$m resolution. A fast experimental sequence is presented, facilitating its use as a magnetic-field-gradient calibration routine, and it is demonstrated that the main limitation is the quantum shot noise.

DOI
10.1103/physreva.83.062329

Related papers

Experimental proposal on scalable radio-frequency magnetometer with trapped ions

Yuxiang Huang, Wei Wu, Qingyuan Mei +1 more

Quantum magnetometry represents a fundamental component of quantum metrology, where trapped-ion systems have achieved $\rm{pT}/\sqrt{\rm{Hz}}$ sensitivity in single-ion radio-frequency magnetic field measurements via dressed states based dynamical decoupling. Here we propose a scalable trapped-ion magnetometer utilizing the mixed dynamical decoupling method, combining dressed states with periodic sequences to suppress decoherence and spatial magnetic field inhomogeneity. With numerical simulations for a $10^4$ ion system with realistic experimental parameters, we demonstrate that a sensitivity of 13 $\rm{fT}/\sqrt{\rm{Hz}}$ for the radio-frequency field could be reached. Such a sensitivity could be obtained via robust resilience to magnetic field drift noise and inhomogeneity, where coherence time could be extended to the order of several minutes on average. This method enables scalable trapped-ion magnetometry, demonstrating its potential as a robust and practical solution for advancing quantum sensing applications.

arXiv:2510.22516•Physical Review Applied•Nov 19, 2025•1 citation

Scalable surface ion trap design for magnetic quantum sensing and gradiometry

Qirat Iqbal, Altaf Hussain Nizamani

Magnetic quantum sensors based on trapped ions utilize properties of quantum mechanics which have optimized precision and beat current limits in sensor technology. Trapped ions are highly sensitive in a large span of signal ranging from DC or static B-field to the radiofrequency range in 100s of MHz and can attain the sensitivity in the range of pT to sub pT . They are tuneable to frequencies of interest and can be used as a lock-in frequency detector. This modelling and simulation based study presents an innovative design of Surface Paul Traps, enabling the use of trapped ions as ultra-sensitive sensors for magnetic field detection and precise measurement of magnetic field gradients at a sub-millimeter spatial resolution. The novel design features multiple trapping regions, allowing for the mapping of magnetic fields across various ion-trapping zones. The study demonstrates groundbreaking advancements in ion manipulation and confinement through innovative chip architecture.

quant-pharXiv:2604.21342•Physics Open•Apr 24, 2026•3 citations

Real-time magnetic field noise correction using trapped-ion monitor qubits

Kyle DeBry, Agustin Valdes-Martinez, David Reens +2 more

We demonstrate a trapped-ion protocol in which a nearby, dedicated "monitor" qubit tracks magnetic-field drifts in real time without interrupting data-qubit operations. Using two $^{40}\mathrm{Ca}^+$ ions and the optical--metastable--ground architecture, we encode the data qubit in the ground-state manifold and the monitor qubit in a metastable-state manifold to achieve spectral separation. The monitor qubit senses common magnetic fluctuations during data-qubit experiments, enabling feedforward corrections to the qubit-control drives. Under applied magnetic noise with a realistic spectrum ($1/f^{2}$), the protocol maintains coherence and, when compared with interleaved calibration, it extends usable data-qubit probe times by up to a factor of ${\sim}\sqrt{2}$ and doubles the experimental duty cycle. These results establish monitor qubits as a scalable tool for real-time recalibration in quantum information processors.

quant-pharXiv:2511.04767•Physical Review A•Nov 10, 2025•1 citation

Development and demonstration of a high bandwidth, ultra sensitive trapped ion magnetometer

Ethan Robert Potter

This thesis describes an ion trap magnetometer, in which experimental hardware and theory for trapped ion magnetometry has been developed and demonstrated. Quantum magnetometry has been a fast expanding field in recent years due to the plethora of military, medical and security applications. The current quantum magnetometer literature has shown great improvements on the standard magnetometer success metrics such as sensitivity, spacial resolution, frequency tuneability, noise shielding and vector field resolution. Ion trap magnetometry could potentially boast several advantages over some of the better established methods such as, nano-meter spatial resolution, broadband tuneability over radio-frequency (RF) and microwave frequencies, and magnetic field noise shielding and sensitivity improvements through dynamic decoupling methods; all in room temperature environments. The experimental setup discussed uses a micro-fabricated Paul trap for ion confinement due to the scalability of this technology. The method for sensing that was demonstrated utilises long-wavelength radiation dressed states to extend the coherence time of a single 171Yb+ ion beyond the bare states and to allow for a high level of frequency tuneability. The coherence times measured were T2 = 0:645 s for RF field sensing at 15.616 MHz and T2 = 1.153 s for microwave field sensing at 12.658466 GHz. Sensitivities of SB = 125.857 ± 26.155 pT/ vHz for RF magnetic fields and SB = 102.054 ± 11.046 pT/ vHz for microwave magnetic fields were achieved experimentally. A novel micro-fabricated Paul trap for trapping multiple ion clusters was developed to improve sensitivity values by increasing the total number of trapped ions. The design confines ions over a two-dimensional surface spanning 0.65 x 1.00 mm which would also allow for magnetic field gradient measurements. Efforts have been made to miniaturise certain experimental hardware to further the development of portable trapped ion experiments. For this, a miniaturised RF resonator that could be used for radial confinement of ions within Paul traps has been developed. At the current stage of development it is capable of applying a peak RF voltage of 114.9 V with a Q value of 70 at a resonant frequency of O/2p = 12.65 MHz.

•Sep 24, 2019•0 citations

Microchip ion traps with high magnetic field gradients for microwave quantum logic

David Murgia

This thesis describes experimental work towards the development of a trapped-ion quantum computer based on microchip ion traps and long-wavelength radiation, using magnetic field gradients. The relationship between experimental parameters and two-qubit gate fidelity is investigated for microchips with two different static magnetic field gradient generation methods. For current-carrying wires and under-chip permanent magnets, optimum ion heights of 110 μm and 200 μm are found respectively. Construction of an experiment capable of demonstrating high-fidelity gates is reported, including innovations for the use of microchip ion traps with permanent magnets. The development of a vacuum system for versatile microchip experiments is described, including new methods for impedance-matched RF delivery, in-vacuum filtering and liquid nitrogen microchip cooling. Protection of both the microchip surface from atomic flux and of ions from the charged imaging viewport are both investigated in detail. A new preparation framework for microchip ion traps before their use in experiments is developed. In order to remove unwanted deposited layers on the microchips, a process of multiple chemical treatments is used. In addition, these characterisation efforts lead to refinement of the microfabrication process for future microchips. The application of large currents to microchips is of fundamental importance to scalable trapped-ion quantum computing using static magnetic field gradients. As part of the characterisation process, currents of ≈ 10A are successfully applied to microfabricated current-carrying wires, demonstrating the viability of these structures for generation of local magnetic fields and gradients in a quantum computing device. The operation of a microchip ion trap experiment with under-chip permanent magnets for a high magnetic field gradient (≈ 140Tm−1) is described. The successful trapping of ytterbium-174 and -171 ions is reported, as well as their use to measure and optimise the ion trap parameters. The thesis concludes with consideration of the expected future results from the ongoing operation of the experiment.

•Nov 1, 2016•0 citations

Automated Magnetic Field Stabilization for Trapped-Ion Quantum Networking Experiments

Saketha Male

Magnetic field fluctuations are a dominant source of dephasing in Zeeman-encoded trapped-ion qubits, limiting coherence time and the fidelity of quantum operations, particularly in modular quantum networks where phase stability must be maintained across spatially separated nodes. In this work, we design and characterize an active magnetic field stabilization system based on real-time feedback using a high-resolution magnetometer, a digitally controlled Red Pitaya platform, and a coil actuator with a measured gain of ∼ −5.37 G/V. Spectral measurements of the laboratory environment reveal dominant 60 Hz magnetic noise with amplitudes on the order of 400 µG and significant harmonic content. The system operates at a sampling rate of ∼ 605 Hz with an actuator bandwidth of ∼ 85 Hz, enabling targeted suppression of these low-frequency components. Given a Zeeman sensitivity of ∼ 2.8 MHz/G, such fluctuations correspond to kilohertz-scale frequency noise, which rapidly dephases qubit superpositions. Suppression of these fluctuations is therefore expected to reduce phase noise and extend coherence times, with first-order estimates suggesting improvement from the submillisecond regime into the few-millisecond regime for Zeeman-sensitive qubits. These results demonstrate that active magnetic-field stabilization is a practical approach to reducing environmental dephasing and improving the performance of trapped-ion quantum network experiments.

•Jun 5, 2026•0 citations
It is expected that ion-trap quantum computing can be made scalable through protocols that make use of transport of ion qubits between subregions within the ion trap. In this scenario, any magnetic field inhomogeneity the ion experiences during the transport may lead to dephasing and loss of fidelity. Here we demonstrate how to measure, and compensate for, magnetic field gradients inside a segmented ion trap, by transporting a single ion over variable distances. We attain a relative magnetic field sensitivity of \ensuremathΔB/B0 5\ifmmode×\else\texttimes\fi10\ensuremath−7\ensuremath{\Delta}B/{B}_{0}~5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}\ensuremathΔB/B0​ 5\ifmmode×\else\texttimes\fi10\ensuremath−7 over a test distance of 140 \ensuremathμ\ensuremath{\mu}\ensuremathμm, which can be extended to the mm range, still with sub-\ensuremathμ\ensuremath{\mu}\ensuremathμm resolution. A fast experimental sequence is presented, facilitating its use as a magnetic-field-gradient calibration routine, and it is demonstrated that the main limitation is the quantum shot noise.
Quantum magnetometry represents a fundamental component of quantum metrology, where trapped-ion systems have achieved pT/Hz\rm{pT}/\sqrt{\rm{Hz}}pT/Hz​ sensitivity in single-ion radio-frequency magnetic field measurements via dressed states based dynamical decoupling. Here we propose a scalable trapped-ion magnetometer utilizing the mixed dynamical decoupling method, combining dressed states with periodic sequences to suppress decoherence and spatial magnetic field inhomogeneity. With numerical simulations for a 10410^4104 ion system with realistic experimental parameters, we demonstrate that a sensitivity of 13 fT/Hz\rm{fT}/\sqrt{\rm{Hz}}fT/Hz​ for the radio-frequency field could be reached. Such a sensitivity could be obtained via robust resilience to magnetic field drift noise and inhomogeneity, where coherence time could be extended to the order of several minutes on average. This method enables scalable trapped-ion magnetometry, demonstrating its potential as a robust and practical solution for advancing quantum sensing applications.
Magnetic quantum sensors based on trapped ions utilize properties of quantum mechanics which have optimized precision and beat current limits in sensor technology. Trapped ions are highly sensitive in a large span of signal ranging from DC or static B-field to the radiofrequency range in 100s of MHz and can attain the sensitivity in the range of pT to sub pT . They are tuneable to frequencies of interest and can be used as a lock-in frequency detector. This modelling and simulation based study presents an innovative design of Surface Paul Traps, enabling the use of trapped ions as ultra-sensitive sensors for magnetic field detection and precise measurement of magnetic field gradients at a sub-millimeter spatial resolution. The novel design features multiple trapping regions, allowing for the mapping of magnetic fields across various ion-trapping zones. The study demonstrates groundbreaking advancements in ion manipulation and confinement through innovative chip architecture.
We demonstrate a trapped-ion protocol in which a nearby, dedicated "monitor" qubit tracks magnetic-field drifts in real time without interrupting data-qubit operations. Using two 40Ca+^{40}\mathrm{Ca}^+40Ca+ ions and the optical--metastable--ground architecture, we encode the data qubit in the ground-state manifold and the monitor qubit in a metastable-state manifold to achieve spectral separation. The monitor qubit senses common magnetic fluctuations during data-qubit experiments, enabling feedforward corrections to the qubit-control drives. Under applied magnetic noise with a realistic spectrum (1/f21/f^{2}1/f2), the protocol maintains coherence and, when compared with interleaved calibration, it extends usable data-qubit probe times by up to a factor of ∼2{\sim}\sqrt{2}∼2​ and doubles the experimental duty cycle. These results establish monitor qubits as a scalable tool for real-time recalibration in quantum information processors.
This thesis describes an ion trap magnetometer, in which experimental hardware and theory for trapped ion magnetometry has been developed and demonstrated. Quantum magnetometry has been a fast expanding field in recent years due to the plethora of military, medical and security applications. The current quantum magnetometer literature has shown great improvements on the standard magnetometer success metrics such as sensitivity, spacial resolution, frequency tuneability, noise shielding and vector field resolution. Ion trap magnetometry could potentially boast several advantages over some of the better established methods such as, nano-meter spatial resolution, broadband tuneability over radio-frequency (RF) and microwave frequencies, and magnetic field noise shielding and sensitivity improvements through dynamic decoupling methods; all in room temperature environments. The experimental setup discussed uses a micro-fabricated Paul trap for ion confinement due to the scalability of this technology. The method for sensing that was demonstrated utilises long-wavelength radiation dressed states to extend the coherence time of a single 171Yb+ ion beyond the bare states and to allow for a high level of frequency tuneability. The coherence times measured were T2 = 0:645 s for RF field sensing at 15.616 MHz and T2 = 1.153 s for microwave field sensing at 12.658466 GHz. Sensitivities of SB = 125.857 ± 26.155 pT/ vHz for RF magnetic fields and SB = 102.054 ± 11.046 pT/ vHz for microwave magnetic fields were achieved experimentally. A novel micro-fabricated Paul trap for trapping multiple ion clusters was developed to improve sensitivity values by increasing the total number of trapped ions. The design confines ions over a two-dimensional surface spanning 0.65 x 1.00 mm which would also allow for magnetic field gradient measurements. Efforts have been made to miniaturise certain experimental hardware to further the development of portable trapped ion experiments. For this, a miniaturised RF resonator that could be used for radial confinement of ions within Paul traps has been developed. At the current stage of development it is capable of applying a peak RF voltage of 114.9 V with a Q value of 70 at a resonant frequency of O/2p = 12.65 MHz.
This thesis describes experimental work towards the development of a trapped-ion quantum computer based on microchip ion traps and long-wavelength radiation, using magnetic field gradients. The relationship between experimental parameters and two-qubit gate fidelity is investigated for microchips with two different static magnetic field gradient generation methods. For current-carrying wires and under-chip permanent magnets, optimum ion heights of 110 μm and 200 μm are found respectively. Construction of an experiment capable of demonstrating high-fidelity gates is reported, including innovations for the use of microchip ion traps with permanent magnets. The development of a vacuum system for versatile microchip experiments is described, including new methods for impedance-matched RF delivery, in-vacuum filtering and liquid nitrogen microchip cooling. Protection of both the microchip surface from atomic flux and of ions from the charged imaging viewport are both investigated in detail. A new preparation framework for microchip ion traps before their use in experiments is developed. In order to remove unwanted deposited layers on the microchips, a process of multiple chemical treatments is used. In addition, these characterisation efforts lead to refinement of the microfabrication process for future microchips. The application of large currents to microchips is of fundamental importance to scalable trapped-ion quantum computing using static magnetic field gradients. As part of the characterisation process, currents of ≈ 10A are successfully applied to microfabricated current-carrying wires, demonstrating the viability of these structures for generation of local magnetic fields and gradients in a quantum computing device. The operation of a microchip ion trap experiment with under-chip permanent magnets for a high magnetic field gradient (≈ 140Tm−1) is described. The successful trapping of ytterbium-174 and -171 ions is reported, as well as their use to measure and optimise the ion trap parameters. The thesis concludes with consideration of the expected future results from the ongoing operation of the experiment.
Magnetic field fluctuations are a dominant source of dephasing in Zeeman-encoded trapped-ion qubits, limiting coherence time and the fidelity of quantum operations, particularly in modular quantum networks where phase stability must be maintained across spatially separated nodes. In this work, we design and characterize an active magnetic field stabilization system based on real-time feedback using a high-resolution magnetometer, a digitally controlled Red Pitaya platform, and a coil actuator with a measured gain of ∼ −5.37 G/V. Spectral measurements of the laboratory environment reveal dominant 60 Hz magnetic noise with amplitudes on the order of 400 µG and significant harmonic content. The system operates at a sampling rate of ∼ 605 Hz with an actuator bandwidth of ∼ 85 Hz, enabling targeted suppression of these low-frequency components. Given a Zeeman sensitivity of ∼ 2.8 MHz/G, such fluctuations correspond to kilohertz-scale frequency noise, which rapidly dephases qubit superpositions. Suppression of these fluctuations is therefore expected to reduce phase noise and extend coherence times, with first-order estimates suggesting improvement from the submillisecond regime into the few-millisecond regime for Zeeman-sensitive qubits. These results demonstrate that active magnetic-field stabilization is a practical approach to reducing environmental dephasing and improving the performance of trapped-ion quantum network experiments.