Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1101.4206 · Optics Express

Absorption imaging of ultracold atoms on atom chips

David A. Smith, Simon Aigner, Sebastian Hofferberth, Michael Gring, L. Mauritz Andersson, Stefan Wildermuth, P. Krüger, Stephan Schneider, Thorsten Schumm, Jörg Schmiedmayer

Published Apr 18, 2011• 66 citations
arXivHTMLPDF

Abstract

Imaging ultracold atomic gases close to surfaces is an important tool for the detailed analysis of experiments carried out using atom chips. We describe the critical factors that need be considered, especially when the imaging beam is purposely reflected from the surface. In particular we present methods to measure the atom-surface distance, which is a prerequisite for magnetic field imaging and studies of atom surface-interactions.

DOI
10.1364/oe.19.008471

Related papers

Scanning magnetoresistance microscopy of atom chips

Michael Volk, S. Whitlock, C. H. Wolff +2 more

Surface based geometries of microfabricated wires or patterned magnetic films can be used to magnetically trap and manipulate ultracold neutral atoms or Bose-Einstein condensates. We investigate the magnetic properties of such atom chips using a scanning magnetoresistive (MR) microscope with high spatial resolution and high field sensitivity. By comparing MR scans of a permanent magnetic atom chip to field profiles obtained using ultracold atoms, we show that MR sensors are ideally suited to observe small variations of the magnetic field caused by imperfections in the wires or magnetic materials which ultimately lead to fragmentation of ultracold atom clouds. Measurements are also provided for the magnetic field produced by a thin current-carrying wire with small geometric modulations along the edge. Comparisons of our measurements with a full numeric calculation of the current flow in the wire and the subsequent magnetic field show excellent agreement. Our results highlight the use of scanning MR microscopy as a convenient and powerful technique for precisely characterizing the magnetic fields produced near the surface of atom chips.

arXiv:0704.3137•Review of Scientific Instruments•Feb 1, 2008•8 citations

Surface-plasmon-based dispersive detection and spectroscopy of ultracold atoms

Matthias Mildner, Claus Zimmermann, Sebastian Slama

The paper reports on the optical detection and spectroscopy of ultracold atoms near a gold surface.A probe light field is used to excite surface plasmon polaritons.The refractive index of the atomic gas shifts the plasmon resonance and changes the reflected light power.Thus, the sensitivity of the detection is plasmonically enhanced.Absorption of photons from the evanescent wave is avoided by detuning the laser from atomic resonance which makes the detection scheme potentially nondestructive.The spectrum of the signal is determined by a Fano resonance.We show that atoms can be detected nondestructively with single atom resolution for typical parameters in cold atom experiments.Thus, the method is suitable for quantum nondemolition measurements of matter wave amplitudes.Experimentally, we measure a technically limited sensitivity of 30 atoms and extend the detection scheme to dispersively image the atom cloud near the surface.

arXiv:2009.03615•Physical Review Research•Jan 4, 2021•4 citations

Cold atoms close to surfaces: measuring magnetic field roughness and disorder potentials

P. Krüger, Stephan Wildermuth, Sebastian Hofferberth +4 more

Microscopic atom optical devices integrated on atom chips allow to precisely control and manipulate ultra-cold ( T < 1 µK) neutral atoms and Bose-Einstein condensates (BECs) close to surfaces. The relevant energy scale of a BEC is extremely small (down to < 10 −11 eV). Consequently, BECs can be utilized as a sensor for variations of the potential energy of the atoms close to the surface. Here we describe how to use trapped atoms as a measurement device and analyze the performance and flexibility of the field sensor. We demonstrate microscopic magnetic imaging with simultaneous high spatial resolution (3 µm) and high field sensitivity (4 nT). With one dimensional BECs, we probe the magnetic field variations close to the surface at distances down to a few microns. Measurements of the magnetic field of a 100 µm wide current carrying wire imply that the magnetic field variations stem from residual variations of the current flow direction, resulting from local properties of the wire. These disorder potentials found near lithographically fabricated wires are two orders of magnitude smaller than those measured close to electroplated conductors.

Journal of Physics Conference Series•Jan 1, 2005•14 citations

Ultracold atoms on atom chips: Manipulation at the μm distance scale

P. Krüger

Miniaturized potentials near the surface of atom chips can be used as flexible and versatile tools for the manipulation of ultracold atoms on a microscale. The full scope of possibilities is only accessible if atom‐surface distances can be reduced to microns. We discuss experiments in this regime and potential obstacles and solutions. We show that appropriate fabrication techniques lead to a reduction of disorder potentials so that one‐dimensional condensates can be prepared. We demonstrate how electrostatic potentials can be used to modify magnetic trapping potentials and how they can be used to study condensate formation in situations of different dimensionality.

AIP conference proceedings•Jan 1, 2005•1 citation

Sensitive absorption imaging of single atoms in front of a mirror

Atreju Tauschinsky, R. J. C. Spreeuw

In this paper we show that the sensitivity of absorption imaging of ultracold atoms can be significantly improved by imaging in a standing-wave configuration. We present simulations of single-atom absorption imaging both for a travelling-wave and a standing-wave imaging setup, based on a scattering approach to calculate the optical density of a single atom. We find that the optical density of a single atom is determined only by the numerical aperture of the imaging system. We determine optimum imaging parameters, taking all relevant sources of noise into account. For reflective imaging we find an improvement of 1.7 in the maximum signal-to-noise ratio can be achieved. This is particularly useful for imaging in the vicinity of an atom chip, where a reflective surface is naturally present.

arXiv:1302.5378•Optics Express•Apr 16, 2013•3 citations

Ultracold atomic absorption imaging system in high magnetic fields

Yuying 玉莹 Chen 陈, Zhengxi Zhang, Hongmian Shui +3 more

Abstract Absorption imaging is a fundamental technique for quantitatively extracting information from ultracold atom experiments. Since ultracold 6Li atoms are prepared and detected under high magnetic fields, the suitable detuning of the probe light can reach the GHz level compared to zero-field imaging. Therefore, based on the energy level structure of 6Li atoms and the requirements of subsequent experiments, we design a high-field imaging system with a large frequency range and good robustness, starting from the rationality of the optical layout design and employing offset locking techniques. This imaging system covers the entire crossover region from Bose–Einstein condensate to Bardeen–Cooper–Schrieffer (BEC–BCS) and realizes free switching between zero-field and high-field imaging. Additionally, by introducing a proportionality coefficient to correct for the intensity fluctuations of the probe light, we mitigate its disturbance on the statistical measurement of particle numbers in the experiment. This work not only provides a design reference for other quantum gas experiments requiring absorption imaging under strong bias magnetic fields, but also serves as an important reference for improving the imaging performance.

Chinese Physics B•Apr 2, 2025•1 citation
Imaging ultracold atomic gases close to surfaces is an important tool for the detailed analysis of experiments carried out using atom chips. We describe the critical factors that need be considered, especially when the imaging beam is purposely reflected from the surface. In particular we present methods to measure the atom-surface distance, which is a prerequisite for magnetic field imaging and studies of atom surface-interactions.
Surface based geometries of microfabricated wires or patterned magnetic films can be used to magnetically trap and manipulate ultracold neutral atoms or Bose-Einstein condensates. We investigate the magnetic properties of such atom chips using a scanning magnetoresistive (MR) microscope with high spatial resolution and high field sensitivity. By comparing MR scans of a permanent magnetic atom chip to field profiles obtained using ultracold atoms, we show that MR sensors are ideally suited to observe small variations of the magnetic field caused by imperfections in the wires or magnetic materials which ultimately lead to fragmentation of ultracold atom clouds. Measurements are also provided for the magnetic field produced by a thin current-carrying wire with small geometric modulations along the edge. Comparisons of our measurements with a full numeric calculation of the current flow in the wire and the subsequent magnetic field show excellent agreement. Our results highlight the use of scanning MR microscopy as a convenient and powerful technique for precisely characterizing the magnetic fields produced near the surface of atom chips.
The paper reports on the optical detection and spectroscopy of ultracold atoms near a gold surface.A probe light field is used to excite surface plasmon polaritons.The refractive index of the atomic gas shifts the plasmon resonance and changes the reflected light power.Thus, the sensitivity of the detection is plasmonically enhanced.Absorption of photons from the evanescent wave is avoided by detuning the laser from atomic resonance which makes the detection scheme potentially nondestructive.The spectrum of the signal is determined by a Fano resonance.We show that atoms can be detected nondestructively with single atom resolution for typical parameters in cold atom experiments.Thus, the method is suitable for quantum nondemolition measurements of matter wave amplitudes.Experimentally, we measure a technically limited sensitivity of 30 atoms and extend the detection scheme to dispersively image the atom cloud near the surface.
Microscopic atom optical devices integrated on atom chips allow to precisely control and manipulate ultra-cold ( T < 1 µK) neutral atoms and Bose-Einstein condensates (BECs) close to surfaces. The relevant energy scale of a BEC is extremely small (down to < 10 −11 eV). Consequently, BECs can be utilized as a sensor for variations of the potential energy of the atoms close to the surface. Here we describe how to use trapped atoms as a measurement device and analyze the performance and flexibility of the field sensor. We demonstrate microscopic magnetic imaging with simultaneous high spatial resolution (3 µm) and high field sensitivity (4 nT). With one dimensional BECs, we probe the magnetic field variations close to the surface at distances down to a few microns. Measurements of the magnetic field of a 100 µm wide current carrying wire imply that the magnetic field variations stem from residual variations of the current flow direction, resulting from local properties of the wire. These disorder potentials found near lithographically fabricated wires are two orders of magnitude smaller than those measured close to electroplated conductors.
Miniaturized potentials near the surface of atom chips can be used as flexible and versatile tools for the manipulation of ultracold atoms on a microscale. The full scope of possibilities is only accessible if atom‐surface distances can be reduced to microns. We discuss experiments in this regime and potential obstacles and solutions. We show that appropriate fabrication techniques lead to a reduction of disorder potentials so that one‐dimensional condensates can be prepared. We demonstrate how electrostatic potentials can be used to modify magnetic trapping potentials and how they can be used to study condensate formation in situations of different dimensionality.
In this paper we show that the sensitivity of absorption imaging of ultracold atoms can be significantly improved by imaging in a standing-wave configuration. We present simulations of single-atom absorption imaging both for a travelling-wave and a standing-wave imaging setup, based on a scattering approach to calculate the optical density of a single atom. We find that the optical density of a single atom is determined only by the numerical aperture of the imaging system. We determine optimum imaging parameters, taking all relevant sources of noise into account. For reflective imaging we find an improvement of 1.7 in the maximum signal-to-noise ratio can be achieved. This is particularly useful for imaging in the vicinity of an atom chip, where a reflective surface is naturally present.
Abstract Absorption imaging is a fundamental technique for quantitatively extracting information from ultracold atom experiments. Since ultracold 6Li atoms are prepared and detected under high magnetic fields, the suitable detuning of the probe light can reach the GHz level compared to zero-field imaging. Therefore, based on the energy level structure of 6Li atoms and the requirements of subsequent experiments, we design a high-field imaging system with a large frequency range and good robustness, starting from the rationality of the optical layout design and employing offset locking techniques. This imaging system covers the entire crossover region from Bose–Einstein condensate to Bardeen–Cooper–Schrieffer (BEC–BCS) and realizes free switching between zero-field and high-field imaging. Additionally, by introducing a proportionality coefficient to correct for the intensity fluctuations of the probe light, we mitigate its disturbance on the statistical measurement of particle numbers in the experiment. This work not only provides a design reference for other quantum gas experiments requiring absorption imaging under strong bias magnetic fields, but also serves as an important reference for improving the imaging performance.