We report on the use of a single nitrogen-vacancy (NV) center to probe fluctuating ac magnetic fields. Using engineered currents to induce random changes in the field amplitude and phase, we show that stochastic fluctuations reduce the NV center sensitivity and, in general, make the NV response field-dependent. We also introduce two modalities to determine the field spectral composition, unknown a priori in a practical application. One strategy capitalizes on the generation of ac-field-induced coherence “revivals” while the other approach uses the time-tagged fluorescence intensity record from successive NV observations to reconstruct the ac field spectral density. These studies are relevant for magnetic sensing in scenarios where the field of interest has a nontrivial, stochastic behavior, such as sensing unpolarized nuclear spin ensembles at low static magnetic fields.
We report on the use of a single nitrogen-vacancy (NV) center to probe fluctuating ac magnetic fields. Using engineered currents to induce random changes in the field amplitude and phase, we show that stochastic fluctuations reduce the NV center sensitivity and, in general, make the NV response field-dependent. We also introduce two modalities to determine the field spectral composition, unknown a priori in a practical application. One strategy capitalizes on the generation of ac-field-induced coherence “revivals” while the other approach uses the time-tagged fluorescence intensity record from successive NV observations to reconstruct the ac field spectral density. These studies are relevant for magnetic sensing in scenarios where the field of interest has a nontrivial, stochastic behavior, such as sensing unpolarized nuclear spin ensembles at low static magnetic fields.
Magnetic sensors are typically much more sensitive to oscillating (AC) magnetic fields than static (DC) fields, due to the presence of more noise at lower frequency, typically scaling with a 1/f dependence. For quantum magnetometers, this characteristic noise is reflected in the ensemble dephasing time T2∗, the relevant sensing time for a DC field, being much lower than the spin coherence time T2, which determines the sensitivity to AC fields. Here, we demonstrate measurement of DC magnetic fields using a physically rotating ensemble of nitrogen-vacancy centres at a precision limited by the electron spin coherence time, T2. We rotate the host diamond with a period comparable to T2, such that the angle between the NV axis and the magnetic field to be detected changes as a function of time, upconverting the static magnetic field to an oscillating field in the physically rotating frame. Using spin-echo interferometry, we observe an order of magnitude improvement in DC magnetometer response compared to a conventional Ramsey experiments. Enhancements to our scheme could realise DC sensitivities equivalent to demonstrated AC magnetic field sensitivities with NV centres.
So far most well-established quantum sensing techniques based on the negatively charged nitrogen-vacancy (NV) center in diamond utilize the recorded fluorescence intensity to detect the electronic spin states. However, the fluorescence intensity of a NV center is not only dependent on its spin state, but also affected by measurement issues, such as fluctuations of the excitation laser power and charge state transformation of the NV center. Instabilities in terms of output power or polarization changes in the laser source as well as sample drifts during a measurement are common factors that weaken the precision. Here, we demonstrate proof-of-principle of a sensing method making use of the excited-state lifetimes of a NV center for magnetometry experiments.
Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.
Nitrogen-vacancy centers in diamond have been shown to be capable of detecting AC magnetic fields with high sensitivity, spectral resolution, and spatial resolution. However, most studies so far have focused on the regime of time-averaged or time-correlated measurements, while little attention has been paid to the single-shot regime. Here we show that the amplitude and phase of an AC field can be retrieved from a single pair of two consecutive measurements. We demonstrate this concept by measuring a 4 MHz AC field with a per-shot amplitude and phase sensitivity of 78 nT and 63 mrad, respectively, at a temporal resolution of 320 us. We also investigate the effects and quantify the errors resulting from probe frequency detunings, as well as operating in the strong field regime. Moreover, we showcase the ability of the measurement protocol to dynamically change the probe frequency in real-time. This work advances the use of NV centers for real-time measurements of AC magnetic fields.
Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.