Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1008.2012 · Physical Review A

Gaussian approximation and single-spin measurement in magnetic resonance force microscopy with spin noise

Shesha Raghunathan, Todd A. Brun, Hsi‐Sheng Goan

Published Nov 17, 2010• 1 citation
arXivHTMLPDF

Abstract

A promising technique for measuring single electron spins is magnetic resonance force microscopy (MRFM), in which a microcantilever with a permanent magnetic tip is resonantly driven by a single oscillating spin. The most effective experimental technique is the oscillating cantilever-driven adiabatic reversals (OSCAR) protocol, in which the signal takes the form of a frequency shift. If the quality factor of the cantilever is high enough, this signal will be amplified over time to the point where it can be detected by optical or other techniques. An important requirement, however, is that this measurement process occurs on a time scale that is short compared to any noise which disturbs the orientation of the measured spin. We describe a model of spin noise for the MRFM system and show how this noise is transformed to become time dependent in going to the usual rotating frame. We simplify the description of the cantilever-spin system by approximating the cantilever wave function as a Gaussian wave packet and show that the resulting approximation closely matches the full quantum behavior. We then examine the problem of detecting the signal for a cantilever with thermal noise and spin with spin noise, deriving a condition for this to be a useful measurement.

DOI
10.1103/physreva.82.052319

Related papers

Modeling and Simulations of a Single-Spin Measurement Using MRFM

G. P. Berman, F. Borgonovi, V. N. Gorshkov +1 more

We review the quantum theory of a single-spin magnetic resonance force microscopy (MRFM). We concentrate on the novel technique called oscillating cantilever-driven adiabatic reversals (OSCARs), which has been used for a single-spin detection. First we describe the quantum dynamics of the cantilever-spin system using simple estimates in the spirit of the mean field approximation. Then we present the results of our computer simulations of the Schro/spl uml/dinger equation for the wave function of the cantilever-spin system and of the master equation for the density matrix of the system. We demonstrate that the cantilever behaves like a quasi-classical measurement device which detects the spin projection along the effective magnetic field. We show that the OSCAR technique provides continuous monitoring of the single spin, which could be used to detect the mysterious quantum collapses of the wave function of the cantilever-spin system.

arXiv:quant-ph/0410002•IEEE Transactions on Nanotechnology•Jan 1, 2005•4 citations

Quantum Measurement of a Single Spin using Magnetic Resonance Force Microscopy

G. P. Berman, F. Borgonovi, George Chapline +5 more

Single-spin detection is one of the important challenges facing the development of several new technologies, e.g. single-spin transistors and solid-state quantum computation. Magnetic resonance force microscopy with a cyclic adiabatic inversion, which utilizes a cantilever oscillations driven by a single spin, is a promising technique to solve this problem. We have studied the quantum dynamics of a single spin interacting with a quasiclassical cantilever. It was found that in a similar fashion to the Stern-Gerlach interferometer the quantum dynamics generates a quantum superposition of two quasiclassical trajectories of the cantilever which are related to the two spin projections on the direction of the effective magnetic field in the rotating reference frame. Our results show that quantum jumps will not prevent a single-spin measurement if the coupling between the cantilever vibrations and the spin is small in comparison with the amplitude of the radio-frequency external field.

arXiv:quant-ph/0108025•Aug 6, 2001•14 citations

Quantum dynamics of the oscillating cantilever-driven adiabatic reversals in magnetic resonance force microscopy

G. P. Berman, F. Borgonovi, V. I. Tsifrinovich

We simulated the quantum dynamics for magnetic resonance force microscopy (MRFM) in the oscillating cantilever-driven adiabatic reversals (OSCAR) technique. We estimated the frequency shift of the cantilever vibrations and demonstrated that this shift causes the formation of a Schr\"odinger cat state which has some similarities and differences from the conventional MRFM technique which uses cyclic adiabatic reversals of spins. The interaction of the cantilever with the environment is shown to quickly destroy the coherence between the two possible cantilever trajectories. We have shown that using partial adiabatic reversals, one can produce a significant increase in the OSCAR signal.

arXiv:quant-ph/0306107•Quantum Information and Computation•Mar 1, 2004•8 citations

Realistic simulations of single-spin nondemolition measurement by magnetic resonance force microscopy

Todd A. Brun, Hsi‐Sheng Goan

A requirement for many quantum computation schemes is the ability to measure single spins. This paper examines one proposed scheme: magnetic resonance force microscopy (MRFM), including the effects of thermal noise and back action from monitoring. We derive a simplified equation using the adiabatic approximation and produce a stochastic pure state unraveling which is useful for numerical simulations. We also calculate the signal-to-noise ratio for single-spin measurement by MRFM, using a quantum Langevin equation approach.

arXiv:quant-ph/0302178•Physical Review A•Sep 5, 2003•26 citations

Quantum dissipative dynamics of the magnetic resonance force microscope in the single-spin detection limit

Hanno Gassmann, Mahn‐Soo Choi, Hangmo Yi +1 more

We study a model of a magnetic resonance force microscope (MRFM) based on the cyclic adiabatic inversion technique as a high-resolution tool to detect single electron spins. We investigate the quantum dynamics of spin and cantilever in the presence of coupling to an environment. To obtain the reduced dynamics of the combined system of spin and cantilever, we use the Feynman-Vernon influence functional and get results valid at any temperature as well as at arbitrary system-bath coupling strength. We propose that the MRFM can be used as a quantum measurement device, i.e., not only to detect the modulus of the spin but also its direction.

arXiv:cond-mat/0309456•Physical Review B•Mar 22, 2004•9 citations

Single-spin measurement and decoherence in magnetic-resonance force microscopy

G. P. Berman, F. Borgonovi, Hsi‐Sheng Goan +2 more

We consider a simple version of a cyclic adiabatic inversion (CAI) technique in magnetic-resonance force microscopy (MRFM). We study the problem: What component of the spin is measured in the CAI MRFM? We show that the nondestructive detection of the cantilever vibrations provides a measurement of the spin component along the effective magnetic field. This result is based on numerical simulations of the Hamiltonian dynamics (the Schr\"odinger equation) and the numerical solution of the master equation.

arXiv:quant-ph/0210043•Physical review. B, Condensed matter•Mar 27, 2003•21 citations
A promising technique for measuring single electron spins is magnetic resonance force microscopy (MRFM), in which a microcantilever with a permanent magnetic tip is resonantly driven by a single oscillating spin. The most effective experimental technique is the oscillating cantilever-driven adiabatic reversals (OSCAR) protocol, in which the signal takes the form of a frequency shift. If the quality factor of the cantilever is high enough, this signal will be amplified over time to the point where it can be detected by optical or other techniques. An important requirement, however, is that this measurement process occurs on a time scale that is short compared to any noise which disturbs the orientation of the measured spin. We describe a model of spin noise for the MRFM system and show how this noise is transformed to become time dependent in going to the usual rotating frame. We simplify the description of the cantilever-spin system by approximating the cantilever wave function as a Gaussian wave packet and show that the resulting approximation closely matches the full quantum behavior. We then examine the problem of detecting the signal for a cantilever with thermal noise and spin with spin noise, deriving a condition for this to be a useful measurement.
We review the quantum theory of a single-spin magnetic resonance force microscopy (MRFM). We concentrate on the novel technique called oscillating cantilever-driven adiabatic reversals (OSCARs), which has been used for a single-spin detection. First we describe the quantum dynamics of the cantilever-spin system using simple estimates in the spirit of the mean field approximation. Then we present the results of our computer simulations of the Schro/spl uml/dinger equation for the wave function of the cantilever-spin system and of the master equation for the density matrix of the system. We demonstrate that the cantilever behaves like a quasi-classical measurement device which detects the spin projection along the effective magnetic field. We show that the OSCAR technique provides continuous monitoring of the single spin, which could be used to detect the mysterious quantum collapses of the wave function of the cantilever-spin system.
Single-spin detection is one of the important challenges facing the development of several new technologies, e.g. single-spin transistors and solid-state quantum computation. Magnetic resonance force microscopy with a cyclic adiabatic inversion, which utilizes a cantilever oscillations driven by a single spin, is a promising technique to solve this problem. We have studied the quantum dynamics of a single spin interacting with a quasiclassical cantilever. It was found that in a similar fashion to the Stern-Gerlach interferometer the quantum dynamics generates a quantum superposition of two quasiclassical trajectories of the cantilever which are related to the two spin projections on the direction of the effective magnetic field in the rotating reference frame. Our results show that quantum jumps will not prevent a single-spin measurement if the coupling between the cantilever vibrations and the spin is small in comparison with the amplitude of the radio-frequency external field.
We simulated the quantum dynamics for magnetic resonance force microscopy (MRFM) in the oscillating cantilever-driven adiabatic reversals (OSCAR) technique. We estimated the frequency shift of the cantilever vibrations and demonstrated that this shift causes the formation of a Schr\"odinger cat state which has some similarities and differences from the conventional MRFM technique which uses cyclic adiabatic reversals of spins. The interaction of the cantilever with the environment is shown to quickly destroy the coherence between the two possible cantilever trajectories. We have shown that using partial adiabatic reversals, one can produce a significant increase in the OSCAR signal.
A requirement for many quantum computation schemes is the ability to measure single spins. This paper examines one proposed scheme: magnetic resonance force microscopy (MRFM), including the effects of thermal noise and back action from monitoring. We derive a simplified equation using the adiabatic approximation and produce a stochastic pure state unraveling which is useful for numerical simulations. We also calculate the signal-to-noise ratio for single-spin measurement by MRFM, using a quantum Langevin equation approach.
We study a model of a magnetic resonance force microscope (MRFM) based on the cyclic adiabatic inversion technique as a high-resolution tool to detect single electron spins. We investigate the quantum dynamics of spin and cantilever in the presence of coupling to an environment. To obtain the reduced dynamics of the combined system of spin and cantilever, we use the Feynman-Vernon influence functional and get results valid at any temperature as well as at arbitrary system-bath coupling strength. We propose that the MRFM can be used as a quantum measurement device, i.e., not only to detect the modulus of the spin but also its direction.
We consider a simple version of a cyclic adiabatic inversion (CAI) technique in magnetic-resonance force microscopy (MRFM). We study the problem: What component of the spin is measured in the CAI MRFM? We show that the nondestructive detection of the cantilever vibrations provides a measurement of the spin component along the effective magnetic field. This result is based on numerical simulations of the Hamiltonian dynamics (the Schr\"odinger equation) and the numerical solution of the master equation.