We demonstrate a light-shot-noise-limited magnetometer based on the Faraday effect in a hot unpolarized ensemble of rubidium atoms. By using off-resonant, polarization-squeezed probe light, we improve the sensitivity of the magnetometer by 3.2 dB. The technique could improve the sensitivity of the most advanced magnetometers and quantum nondemolition measurements of atomic spin ensembles.
We demonstrate a light-shot-noise-limited magnetometer based on the Faraday effect in a hot unpolarized ensemble of rubidium atoms. By using off-resonant, polarization-squeezed probe light, we improve the sensitivity of the magnetometer by 3.2 dB. The technique could improve the sensitivity of the most advanced magnetometers and quantum nondemolition measurements of atomic spin ensembles.
We consider the limitations due to noise (e.g., quantum projection noise and photon shot-noise) on the sensitivity of an idealized atomic magnetometer that utilizes spin squeezing induced by a continuous quantum nondemolition measurement. Such a magnetometer measures spin precession of N atomic spins by detecting optical rotation of far-detuned light. We show that for very short measurement times, the optimal sensitivity scales as ${N}^{\ensuremath{-}3/4}$; if strongly squeezed probe light is used, the Heisenberg limit of ${N}^{\ensuremath{-}1}$ scaling can be achieved. However, if the measurement time exceeds ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/{N}^{1/2}$ in the former case, or ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}/N$ in the latter, where ${\ensuremath{\tau}}_{\mathrm{r}\mathrm{e}\mathrm{l}}$ is the spin relaxation time, the scaling becomes ${N}^{\ensuremath{-}1/2}$, as for a standard shot-noise-limited magnetometer.
Quantum metrology uses quantum features such as entanglement and squeezing to improve the sensitivity of quantum-limited measurements. Long established as a valuable technique in optical measurements such as gravitational-wave detection, quantum metrology is increasingly being applied to atomic instruments such as matter-wave interferometers, atomic clocks, and atomic magnetometers. Several of these new applications involve dual optical/atomic quantum systems, presenting both new challenges and new opportunities. Here we describe an optical magnetometry system that achieves both shot-noise-limited and projection-noise-limited performance, allowing study of optical magnetometry in a fully-quantum regime [1]. By near-resonant Faraday rotation probing, we demonstrate measurement-based spin squeezing in a magnetically-sensitive atomic ensemble [2-4]. The versatility of this system allows us also to design metrologically-relevant optical nonlinearities, and to perform quantum-noise-limited measurements with interacting photons. As a first interaction-based measurement [5], we implement a non-linear metrology scheme proposed by Boixo et al. with the surprising feature of precision scaling better than the 1/N “Heisenberg limit” [6].
The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.
We study the effect of optical polarization squeezing on the performance of a sensitive, quantum-noise-limited optically pumped magnetometer. We use Bell-Bloom (BB) optical pumping to excite a ^{87}Rb vapor containing 8.2×10^{12} atoms/cm^{3} and Faraday rotation to detect spin precession. The sub-pT/sqrt[Hz] sensitivity is limited by spin projection noise (photon shot noise) at low (high) frequencies. Probe polarization squeezing both improves high-frequency sensitivity and increases measurement bandwidth, with no loss of sensitivity at any frequency, a direct demonstration of the evasion of measurement backaction noise. We provide a model for the quantum noise dynamics of the BB magnetometer, including spin projection noise, probe polarization noise, and measurement backaction effects. The theory shows how polarization squeezing reduces optical noise, while measurement backaction due to the accompanying ellipticity antisqueezing is shunted into the unmeasured spin component. The method is compatible with high-density and multipass techniques that reach extreme sensitivity.
(English) This thesis describes experiments that employ squeezed light to improve the performance of a sensitive optically-pumped magnetometer (OPM). The squeezed light source employs parametric amplification of vacuum fluctuations to produce squeezed vacuum and polarization-squeezed light tunable around the Rb D1 line. The OPM employs Bell-Bloom optical pumping of a high density vapor (with atom number density 10^{13}) and paramagnetic Faraday rotation, also on the Rb D1 line. The setup allows convenient switching from probing with laser light to probing with polarization-squeezed light, to study the use of the latter in atomic magnetometry. The magnetometer shows sub-pT/Hz^{1/2} sensitivity, limited by quantum noise; spin projection noise at low frequencies (<100Hz) and photon shot noise at high frequencies. Probing with polarization squeezed light suppresses the photon shot noise by 2dB, limited by the available squeezing and optical losses in passing through the vapor. This shot-noise suppression improves the high-frequency sensitivity and increases the measurement bandwidth, with no observed loss of sensitivity at any frequency. This result confirms experimentally the expected evasion of measurement back-action noise in the Bell-Bloom magnetometer. The thesis also develops a physical model to explain the observed spin dynamics of the Bell-Bloom magnetometer. The model describes the combined spin and optical polarization dynamics using Bloch equations with stochastic drive and detection noise terms. A perturbative approach and Fourier methods are then used to obtain analytic expressions for the magnetometer's frequency response, spin projection noise and photon shot noise. The role of measurement back-action emerges from a study of this model. As polarization squeezing reduces optical noise in the detected Stokes parameter, the accompanying ellipticity anti-squeezing is shunted into the unmeasured spin component. The thesis also reports a study of squeezed-light-enhanced magnetometry at a range of atomic densities, from 2.18 10^{12} atoms/cm3 to 1.13 10^{13} atoms/cm3 . Operating with fixed conditions of optical pumping, the signal amplitude, instrument noise spectrum and magnetic resonance width are measured as a function of atomic number density, for both laser- and squeezed-light probing. The equivalent magnetic noise spectra are then calculated. In the photon-shot-noise-limited portion of the spectrum, the squeezed light probing improves the magnetometer's sensitivity and measurement bandwidth for the full range of atomic density values. In particular, the laser-probed magnetometer shows a sensitivity optimum at n ~ 6 10 ^{12} atoms/cm3, and the squeezed-light-probed magnetometer surpasses this sensitivity. The thesis concludes with a discussion of the potential of stronger optical squeezing to enhance the instrument's sensitivity in different portions of the spectrum. Using the theory model we estimate the enhancement of the equivalent magnetic noise spectrum for 2 dB , 5.6 dB and perfect squeezing (zero noise in the detected polarization component) at the input to the atomic medium. (Català) Aqueta tesi descriu la millora d’un magnetòmetre de bombeig òptic (OPM) mitjançant l’ús d’estats de llum amb incertesa comprimida (squeezed states). S’usa amplificació paramètrica per a comprimir la incertesa de la font de llum. En concret, es comprimeix la incertesa de l’estat de buit quàntic, com també de la polarització òptica, amb la possibilitar d’ajustar la longitud d’ona al voltant de la transició atòmica D1 de 87Rb. L’OPM usa bombeig òptic Bell-Bloom de vapors d’alta densitat (amb densitats atòmiques properes a 1013) i rotació de Faraday, també al voltant de la transició atòmica D1 de 87Rb. L’aparell experimental permet canviar de mostreig amb llum coherent làser a mostreig amb llum de polarització comprimida, amb la finalitat d’avaluar el seu impacte en la sensitivitat del magnetòmetre. El magnetòmetre té una sensitivitat de sub-pT{ ?Hz , principalment limitada per soroll quàntic; soroll de projecció de spin a baixes freqüències (À 100 Hz) i soroll de quantització fotònica a altes freqüències. L’ús d’estats de llum amb polarització comprimida permet reduir el soroll fotònic en „ 2 dB, limitat per la compressió disponible i les pèrdues en travessar el vapor atòmic. La supressió del soroll fotònic augmenta l’amplada de banda del sistema amb l’avantatge de no perdre sensitivitat a cap banda de freqüència. Els resultats experimentals confirmen l’esperada supressió de retroalimentació de soroll en magnetòmetres de Bell-Bloom. La tesi també estudia el model teòric darrere les dinàmiques de spin en un magnetòmetre de tipus Bell-Bloom. El model descriu la combinació de les dinàmiques de spin i de la polarització òptica mitjançant equacions de Bloch forcades estocàsticament i amb termes de soroll de detecció. Es treballa en el límit pertorbatiu on mitjançant mètodes de Fourier s’obtenen expressions analítiques de la resposta en freqüència del magnetòmetre, dels sorolls de projecció de spin i del soroll de quantització fotònica. El rol de la retroalimentació de soroll també s’extrau d’aquest model. En concret, s’observa que la compressió en polarització redueix el soroll en els paràmetres de Stokes detectats, mentre els paràmetres de spin no mesurats experimenten una expansió de la seva incertesa (anti-squeezing). La tesi estudia magnetòmetres òptics de llum amb incertesa comprimida per a densitats entre 2.18 ˆ 1012 atoms{cm3 i 1.13 ˆ 1013 atoms{cm3. Es mesuren l’amplitud de senyal, l’espectre de soroll i l’amplada de la ressonància magnètica en funció de la densitat atòmica, per a un bombeig òptic constant i per a ambdós tipus de mostreig òptic (llum coherent i llum de polarització comprimida). A continuació, es calculen els espectres de soroll equivalents. En la part d’espectre on domina el soroll de quantització fotònica, s’observa que l’ús de llum de polarització comprimida millora la sensitivitat del magnetòmetre al llarg de tot el rang de densitats atòmics. En concret, la sensitivitat del magnetòmetre amb mostreig coherent és òptima per a n « 6ˆ1012 atoms{cm3 i es demostra una millora amb l’ús de mostreig amb llum comprimida. Es conclou amb una discussió sobre l’efecte de compressions més severes en la sensitivitat del magnetòmetre. Mitjançant el model teòric s’estima la millora en la sensitivitat per a compressions de 2 dB, 5.6 dB i “compressió perfecta” a l’entrada del medi atòmic