Nuclear-magnetic-resonance gyroscopes that detect rotation as a shift in the precession frequency of nuclear spins have attracted a lot of attention. Under a feedback-generated drive, the precession frequency in the steady state is supposed to be dependent only on the angular momentum and an applied magnetic field. However, nuclei with spins larger than 1/2 experience electric quadrupole interaction with electric-field gradients at the cell walls. This quadrupole interaction shifts the precession frequencies of the nuclear spins, which brings inaccuracy to the rotation measurement as the quadrupole interaction constant
Cq is difficult to precisely measure. In this paper, the effects of quadrupole interaction on nuclear-magnetic-resonance gyroscopes are theoretically studied. We find that, when the constant
Cq is small compared to the characteristic decay rate of the system, which is the case in most gyroscopes for practical use, as the strength of the feedback-driving field increases, the quadrupole shift monotonically decreases, regardless of the system parameters in including
Cq. Furthermore, the larger driving amplitude can reduce the quadrupole shift's fluctuation caused by fluctuations of the system parameters, and, thus, it can reduce systematic errors resulted from the quadrupole interaction. In the large-
Cq regime, more than one precession frequency exists, and the nuclear spins may precess with a single frequency or multifrequencies depending on initial conditions. In this regime with large driving amplitudes, the nuclear spin can restore the single-frequency precession. These results are obtained by solving an effective master equation of the nuclear spins in a rotating frame from which both the steady-state solutions and the dynamics of the system are shown.
We report nuclear quadrupole resonance (NQR) frequency and linewidth variations of the Pr3+ ground-state hyperfine levels for various positions within the 3H4(Γ1)–1D2(Γ1) inhomogeneous optical line and satellite transitions of Pr3+:LaF3. A linear increase in the broadening of the Pr3+ hyperfine transitions, without a shift of central frequency, is measured by the Stark modulated optical pumping hole-burning technique as the laser is tuned toward the wings of the inhomogeneous optical transition. The linear variation is attributed to electric quadrupole broadening caused by changes in the local density of point defects across the Stark-broadened optical transition. The optically detected NQR spectra of the satellite transitions associated with Pr ion pairs are shifted in frequency and for most satellites are narrower than the NQR spectra found in the wings of the main inhomogeneous optical line.