Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0912.4085 · Physical Review Letters

Backaction Amplification and Quantum Limits in Optomechanical Measurements

P. Verlot, Alexandros Tavernarakis, Tristan Briant, P.-F. Cohadon, A. Heidmann

Published Mar 31, 2010• 108 citations
arXivHTMLPDF

Abstract

Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10(-20) m/square root(Hz) level in the large-scale gravitational-wave interferometers currently in operation. Second-generation interferometers will experience a tenfold improvement in sensitivity and be mainly limited by quantum noise, close to the standard quantum limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure backaction in a detuned cavity.

DOI
10.1103/physrevlett.104.133602

Related papers

Surpassing the Standard Quantum Limit Using an Optical Spring

T. J. Cullen, Ronald Pagano, Scott Aronson +9 more

Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.

arXiv:2210.12222•Physical Review Letters•Sep 13, 2024•5 citations

Quantum variational measurement and the optical lever intracavity topology of gravitational-wave detectors

Farit Ya. Khalili

The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.

arXiv:gr-qc/0607028•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 19, 2007•6 citations

Observation of radiation-pressure effects and back-action cancellation in interferometric measurements

A. Heidmann, T. Caniard, P. Verlot +2 more

Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very highfinesse optical cavity the displacements of a mirror with a sensitivity at the 10-20 m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already report the first experimental demonstration of a back-action noise cancellation. Using a classical radiation-pressure noise to mimic the quantum noise of light, we have observed a drastic improvement of sensitivity both in position and force measurements.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 8, 2008•0 citations

Quantum and dynamical back-action effects using a gram-scale mechanical resonator in a high-finesse optical cavity

Alexandros Tavernarakis

Cavity Optomechanics, that is the study of the interaction between an optical cavity mode and a mechanical degree of freedom, has known impressive evolution over the past decade, to become a new field at the union of condensed matter physics and optics. One of the major goals of this discipline is to test and study quantum mechanics using macroscopic systems. Among the most fundamental problems the community aims to address is the question of the quantum limits in position measurement. Quantum mechanics predicts that any measurement comes along with a backaction, which perturbs the state of the measured system. Moreover, it is expected to be conjugated with the quantum noise of the measurement apparatus (called measurement noise) used to probe the system. The optimal sensitivity is reached whenever both the measurement and the backaction noise are identical, a situation which can be assimilated to the acceptance of Heisenberg's inequality for the measurement apparatus. In cavity optomechanics, the mode of an optical cavity is used as a measurement apparatus of the position of a mechanical resonator which is expected to be responsible for the backaction imprecision. However, this so-called radiation pressure quantum backaction has never been observed to date, while it remains a decisive step towards understanding quantum measurement processes. We describe in this manuscript the study of radiation pressure effects in cavity optomechanics. We introduce the optomechanical system we have developed, which consists in a cm-scale ultra high Q (~ 1 000 000) plano-convex mechanical resonator incorporated into a ultra-high finesse (~ 300 000) Fabry-Prot cavity. We present two important results we obtained with this system. First, we were able to report the first direct observation of radiation pressure in real-time, based on establishing pump-probe correlations. We were also able to demonstrate for the first time nonlinear backaction effects related to substantial improvement of position measurement sensitivity. We explain why demonstrating quantum backaction requires ultra-high stability of the optical mode. We present important changes made to the previous experimental setup, notably on the laser source, on the detection and the stabilization of the experiment. We then describe a new optomechanical detection technique providing an independent measurement of the cavity detuning. Finally, we present a proof-of-principle experiment allowing to extract quantum optomechanical correlations at room temperature.

•Dec 20, 2012•0 citations

Quantum optomechanical correlations induced by radiation pressure between light and mirrors

Tristan Briant, P. Verlot, Alexandros Tavernarakis +2 more

Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very high-finesse optical cavity the displacements of a mirror with a sensitivity at the 10-20m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already have demonstrated radiation-pressure induced correlations between two optical beams sent into the same moving mirror cavity. Our scheme can be extended down to the quantum level and has applications both in high-sensitivity measurements and in quantum optics.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 29, 2008•2 citations

Combining quantum noise reduction resources: A practical approach

Sohitri Ghosh, Matthew A. Feldman, Seongjin Hong +4 more

Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. We demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.

arXiv:2211.14460•Physical Review A•Jun 26, 2025•6 citations
Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10(-20) m/square root(Hz) level in the large-scale gravitational-wave interferometers currently in operation. Second-generation interferometers will experience a tenfold improvement in sensitivity and be mainly limited by quantum noise, close to the standard quantum limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure backaction in a detuned cavity.
Quantum mechanics places noise limits and sensitivity restrictions on physical measurements. The balance between unwanted backaction and the precision of optical measurements imposes a standard quantum limit (SQL) on interferometric systems. In order to realize a sensitivity below the SQL, it is necessary to leverage a backaction evading measurement technique, reduce thermal noise to below the level of backaction, and exploit cancellations of any excess noise contributions at the detector. Many proof of principle experiments have been performed, but only recently has an experiment achieved sensitivity below the SQL. In this work, we extend that initial demonstration and realize sub-SQL sensitivity nearly two times better than previous measurements, and with an architecture applicable to interferometric gravitational wave detectors. In fact, this technique is directly applicable to Advanced LIGO, which could observe similar effects with a detuned signal recycling cavity. We measure a total sensitivity below the SQL by 2.8 dB, corresponding to a reduction in the noise power by 72±5.1% below the quantum limit. Through the use of a detuned cavity and the optical spring effect, this noise reduction is tunable, allowing us to choose the desired range of frequencies that fall below the SQL. This result demonstrates access to sensitivities well below the SQL at frequencies applicable to LIGO, with the potential to extend the reach of gravitational wave detectors further into the Universe.
The intracavity topologies of laser gravitational-wave detectors proposed several years ago are the promising way to obtain sensitivity of these devices significantly better than the Standard Quantum Limit (SQL). In essence, the intracavity detector is a two-stage device where the end mirrors displacement created by the gravitational wave is transferred to the displacement of an additional local mirror by means of the optical rigidity. The local mirror positions have to be monitored by an additional local meter. It is evident that the local meter precision defines the sensitivity of the detector. To overcome the SQL, the quantum variational measurement can be used in the local meter. In this method a frequency-dependent correlation between the meter backaction noise and measurement noise is introduced, which allows us to eliminate the backaction noise component from the meter output signal. This correlation is created by means of an additional filter cavity. In this article the sensitivity limitations of this scheme imposed by the optical losses both in the local meter itself and in the filter cavity are estimated. It is shown that the main sensitivity limitation stems from the filter cavity losses. In order to overcome it, it is necessary to increase the filter cavity length. In a preliminary prototype experiment, an approximate 10 m long filter cavity can be used to obtain sensitivity approximately 2--3 times better than the SQL. For future Quantum Non-Demolition (QND) gravitational-wave detectors with sensitivity about 10 times better than the SQL, the filter cavity length should be within kilometer range.
Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very highfinesse optical cavity the displacements of a mirror with a sensitivity at the 10-20 m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already report the first experimental demonstration of a back-action noise cancellation. Using a classical radiation-pressure noise to mimic the quantum noise of light, we have observed a drastic improvement of sensitivity both in position and force measurements.
Cavity Optomechanics, that is the study of the interaction between an optical cavity mode and a mechanical degree of freedom, has known impressive evolution over the past decade, to become a new field at the union of condensed matter physics and optics. One of the major goals of this discipline is to test and study quantum mechanics using macroscopic systems. Among the most fundamental problems the community aims to address is the question of the quantum limits in position measurement. Quantum mechanics predicts that any measurement comes along with a backaction, which perturbs the state of the measured system. Moreover, it is expected to be conjugated with the quantum noise of the measurement apparatus (called measurement noise) used to probe the system. The optimal sensitivity is reached whenever both the measurement and the backaction noise are identical, a situation which can be assimilated to the acceptance of Heisenberg's inequality for the measurement apparatus. In cavity optomechanics, the mode of an optical cavity is used as a measurement apparatus of the position of a mechanical resonator which is expected to be responsible for the backaction imprecision. However, this so-called radiation pressure quantum backaction has never been observed to date, while it remains a decisive step towards understanding quantum measurement processes. We describe in this manuscript the study of radiation pressure effects in cavity optomechanics. We introduce the optomechanical system we have developed, which consists in a cm-scale ultra high Q (~ 1 000 000) plano-convex mechanical resonator incorporated into a ultra-high finesse (~ 300 000) Fabry-Prot cavity. We present two important results we obtained with this system. First, we were able to report the first direct observation of radiation pressure in real-time, based on establishing pump-probe correlations. We were also able to demonstrate for the first time nonlinear backaction effects related to substantial improvement of position measurement sensitivity. We explain why demonstrating quantum backaction requires ultra-high stability of the optical mode. We present important changes made to the previous experimental setup, notably on the laser source, on the detection and the stabilization of the experiment. We then describe a new optomechanical detection technique providing an independent measurement of the cavity detuning. Finally, we present a proof-of-principle experiment allowing to extract quantum optomechanical correlations at room temperature.
Radiation pressure exerted by light in interferometric measurements is responsible for displacements of mirrors which appear as an additional back-action noise and limit the sensitivity of the measurement. We experimentally study these effects by monitoring in a very high-finesse optical cavity the displacements of a mirror with a sensitivity at the 10-20m/√Hz level. This unique sensitivity is a step towards the first observation of the fundamental quantum effects of radiation pressure and the resulting standard quantum limit in interferometric measurements. Our experiment may become a powerful facility to test quantum noise reduction schemes, and we already have demonstrated radiation-pressure induced correlations between two optical beams sent into the same moving mirror cavity. Our scheme can be extended down to the quantum level and has applications both in high-sensitivity measurements and in quantum optics.
Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. We demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.