arXiv:0909.5083 · Physical Review Letters

Accessing Higher Order Correlations in Quantum Optical States by Time Multiplexing

Malte Avenhaus, Kaisa Laiho, Maria V. Chekhova, Christine Silberhorn

Published Feb 11, 2010• 152 citations
arXivHTMLPDF

Abstract

We experimentally measured higher order normalized correlation functions (NCF) of pulsed light with a time-multiplexing detector. We demonstrate excellent performance of our device by verifying unity valued NCF up to the eighth order for coherent light and factorial dependence of the NCF for pseudothermal light. We applied our measurement technique to a type-II parametric down-conversion source to investigate mutual two-mode correlation properties and ascertain nonclassicality.

DOI
10.1103/physrevlett.104.063602

Related papers

Time-multiplexed measurements of nonclassical light at telecom wavelengths

Georg Harder, Christine Silberhorn, Jaroslav Řeháček +4 more

We report the experimental reconstruction of the statistical properties of an ultrafast pulsed type II parametric down-conversion source in a periodically poled potassium titanyl phosphate waveguide at telecom wavelengths, with almost perfect photon-number correlations. We use a photon-number-resolving time-multiplexed detector based on a fiber-optical setup and a pair of avalanche photodiodes. By resorting to a germane data-pattern tomography, we assess the properties of the nonclassical light states with unprecedented precision.

arXiv:1406.3590•Physical Review A•Oct 7, 2014•24 citations

Uncovering Quantum Correlations with Time-Multiplexed Click Detection

Jan Sperling, Martin Bohmann, W. Vogel +4 more

We report on the implementation of a time-multiplexed click detection scheme to probe quantum correlations between different spatial optical modes. We demonstrate that such measurement setups can uncover nonclassical correlations in multimode light fields even if the single mode reductions are purely classical. The nonclassical character of correlated photon pairs, generated by a parametric down-conversion, is immediately measurable employing the theory of click counting instead of low-intensity approximations with photoelectric detection models. The analysis is based on second- and higher-order moments, which are directly retrieved from the measured click statistics, for relatively high mean photon numbers. No data postprocessing is required to demonstrate the effects of interest with high significance, despite low efficiencies and experimental imperfections. Our approach shows that such novel detection schemes are a reliable and robust way to characterize quantum-correlated light fields for practical applications in quantum communications.

arXiv:1503.08028•Physical Review Letters•Jul 7, 2015•58 citations

Statistical Benchmarking of Scalable Photonic Quantum Systems

Johannes Tiedau, Melanie Engelkemeier, Benjamin Brecht +2 more

Targeting at the realization of scalable photonic quantum technologies, the generation of many photons, their propagation in large optical networks, and a subsequent detection and analysis of sophisticated quantum correlations are essential for the understanding of macroscopic quantum systems. In this experimental contribution, we explore the joint operation of all mentioned ingredients. We benchmark our time-multiplexing framework that includes a high-performance source of multiphoton states and a large multiplexing network, together with unique detectors with high photon-number resolution, readily available for distributing quantum light and measuring complex quantum correlations. Using an adaptive approach that employs flexible time bins, rather than static ones, we successfully verify high-order nonclassical correlations of many photons distributed over many modes. By exploiting the symmetry of our system and using powerful analysis tools, we can analyze correlations that would be inaccessible by classical means otherwise. In particular, we produce on the order of ten photons and distribute them over 64 modes. Nonclassicality is verified with correlation functions up to the 128th order and statistical significances of up to 20 standard deviations.

arXiv:2008.11542•Physical Review Letters•Jan 12, 2021•10 citations

Multi-photon correlations for nonclassical light measured in the pulsed regime

I. N. Agafonov, Maria V. Chekhova, Olga Aleksandrovna Ivanova +1 more

We demonstrate a technique of measuring Glauberpsilas normalized correlation functions for nonclassical light generated in the pulsed regime. In particular, intensity correlation functions are studied for the transition between spontaneous and stimulated parametric down-conversion.

Conference on Lasers and Electro-Optics•Jan 1, 2006•0 citations

Study of the Glauber correlation functions in a pulsed mode

I. N. Agafonov, T. Sh. Iskhakov, Maria V. Chekhova

A method for measuring the Glauber correlation functions in a pulsed mode is proposed. The effect of the detector dead time on the shape of a measured correlation function is analyzed. The second-order intensity correlation functions for coherent and quasi-thermal radiation, as well as for biphoton light emitted during spontaneous parametric down-conversion, are measured in a nanosecond pulsed mode.

Optics and Spectroscopy•Jul 1, 2007•0 citations

Measurements of photon correlations in quasi-coherent optical fields

J. Klebba

The purpose of this investigation was to construct the experimental apparatus for measuring second-order intensity correlation functions of the type T2,2 (x,t,x,t+T) = < : I(x,t)I(x,t+T):>. This measurement was applied to the radiation field produced by a two axial mode Helium-Neon gas laser in order to verify the intensity fluctuation correlations due to the beating of the two axial modes of the laser. The axial mode separation was measured for comparison with a scanning Fabry Perot interferometer and also an RF spectrum analyzer. The correlation measurement was also applied to the second harmonic radiation field produced by the. parametric interaction in a LiNb03 crystal pumped with two axial modes. The experimental determination of the correlation <:I(x,t)I(x,t+T):> involves a time-spectroscopy measurement in which one photon is detected at point x, and another at point x, T seconds later, and measuring the probability of two-fold coincident detection as a function of T. The radiation field was split into two beams at a partially transmitting reflector, each of which was directed incident on the photocathode of a photomultiplier tube. The photoelectron pulses from the tubes were amplified and standardized. These standardized pulses were then temporally correlated with the use of a time-to-amplitude converter (TAC) and a multi-channel pulse height analyzer (MA). The time-to-amplitude conversions generated by the TAC were stored in the channels of the PHA, which was a direct measure of the two-fold delayed coincidence detection rate, R(T). The second-order intensity correlation functions <:I(x,t)I(x,t+T):> are determined from measurements of R(T). The fluctuating components of the second-order intensity correlation functions were found to be in agreement with what would be expected on a classical basis. Correspondingly, the capability is demonstrated of the experimental apparatus measuring a quantity relating to the second-order intensity correlation function.

•Jan 1, 1970•0 citations
We experimentally measured higher order normalized correlation functions (NCF) of pulsed light with a time-multiplexing detector. We demonstrate excellent performance of our device by verifying unity valued NCF up to the eighth order for coherent light and factorial dependence of the NCF for pseudothermal light. We applied our measurement technique to a type-II parametric down-conversion source to investigate mutual two-mode correlation properties and ascertain nonclassicality.
We report the experimental reconstruction of the statistical properties of an ultrafast pulsed type II parametric down-conversion source in a periodically poled potassium titanyl phosphate waveguide at telecom wavelengths, with almost perfect photon-number correlations. We use a photon-number-resolving time-multiplexed detector based on a fiber-optical setup and a pair of avalanche photodiodes. By resorting to a germane data-pattern tomography, we assess the properties of the nonclassical light states with unprecedented precision.
We report on the implementation of a time-multiplexed click detection scheme to probe quantum correlations between different spatial optical modes. We demonstrate that such measurement setups can uncover nonclassical correlations in multimode light fields even if the single mode reductions are purely classical. The nonclassical character of correlated photon pairs, generated by a parametric down-conversion, is immediately measurable employing the theory of click counting instead of low-intensity approximations with photoelectric detection models. The analysis is based on second- and higher-order moments, which are directly retrieved from the measured click statistics, for relatively high mean photon numbers. No data postprocessing is required to demonstrate the effects of interest with high significance, despite low efficiencies and experimental imperfections. Our approach shows that such novel detection schemes are a reliable and robust way to characterize quantum-correlated light fields for practical applications in quantum communications.
Targeting at the realization of scalable photonic quantum technologies, the generation of many photons, their propagation in large optical networks, and a subsequent detection and analysis of sophisticated quantum correlations are essential for the understanding of macroscopic quantum systems. In this experimental contribution, we explore the joint operation of all mentioned ingredients. We benchmark our time-multiplexing framework that includes a high-performance source of multiphoton states and a large multiplexing network, together with unique detectors with high photon-number resolution, readily available for distributing quantum light and measuring complex quantum correlations. Using an adaptive approach that employs flexible time bins, rather than static ones, we successfully verify high-order nonclassical correlations of many photons distributed over many modes. By exploiting the symmetry of our system and using powerful analysis tools, we can analyze correlations that would be inaccessible by classical means otherwise. In particular, we produce on the order of ten photons and distribute them over 64 modes. Nonclassicality is verified with correlation functions up to the 128th order and statistical significances of up to 20 standard deviations.
The purpose of this investigation was to construct the experimental apparatus for measuring second-order intensity correlation functions of the type T2,2 (x,t,x,t+T) = < : I(x,t)I(x,t+T):>. This measurement was applied to the radiation field produced by a two axial mode Helium-Neon gas laser in order to verify the intensity fluctuation correlations due to the beating of the two axial modes of the laser. The axial mode separation was measured for comparison with a scanning Fabry Perot interferometer and also an RF spectrum analyzer. The correlation measurement was also applied to the second harmonic radiation field produced by the. parametric interaction in a LiNb03 crystal pumped with two axial modes. The experimental determination of the correlation <:I(x,t)I(x,t+T):> involves a time-spectroscopy measurement in which one photon is detected at point x, and another at point x, T seconds later, and measuring the probability of two-fold coincident detection as a function of T. The radiation field was split into two beams at a partially transmitting reflector, each of which was directed incident on the photocathode of a photomultiplier tube. The photoelectron pulses from the tubes were amplified and standardized. These standardized pulses were then temporally correlated with the use of a time-to-amplitude converter (TAC) and a multi-channel pulse height analyzer (MA). The time-to-amplitude conversions generated by the TAC were stored in the channels of the PHA, which was a direct measure of the two-fold delayed coincidence detection rate, R(T). The second-order intensity correlation functions <:I(x,t)I(x,t+T):> are determined from measurements of R(T). The fluctuating components of the second-order intensity correlation functions were found to be in agreement with what would be expected on a classical basis. Correspondingly, the capability is demonstrated of the experimental apparatus measuring a quantity relating to the second-order intensity correlation function.