Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0909.1465 · Physical Review A

Low-velocity limits of cold-atom clocks

J. Muñoz, Ion Lizuain, Juan Gonzalo Muga

Published Aug 19, 2009• 1 citation
arXivHTMLPDF

Abstract

Fundamental low-energy limits to the accuracy of quantum clock and stopwatch models in which the clock hand motion is activated by the presence of a particle in a region of space have been studied in the past, but their relevance for actual atomic clocks had not been assessed. In this work we address the effect of slow atomic quantum motion on Rabi and Ramsey resonance fringe patterns, as a perturbation of the results based on classical atomic motion. We find the dependence of the fractional error of the corresponding atomic clocks on the atomic velocity and interaction parameters.

DOI
10.1103/physreva.80.022116

Related papers

Cooling, trapping and manipulation of atoms and Bose-Einstein condensates: Applications to metrology

Kristian Helmerson, William D. Phillips

The thermal motion of atoms often imposes limitations on the precision and accuracy of measurements involving those atoms. Atomic beam cesium clocks are one outstanding example, where the typical thermal velocity of the cesium atoms, on the order of 200 m/s, limits the observation time to a few milliseconds in a typical apparatus. This finite observation time results in a linewidth for the microwave resonance whose frequency defines the unit of time. Other motional effects include first- and second-order Doppler effects whose presence limits the performance of such clocks. Because conventional refrigeration would result in the condensation of cesium or other atoms into a solid, researchers sought other means of reducing the thermal motion, a quest that led to laser cooling and electromagnetic manipulation of neutral atoms. Similar techniques have been developed for trapped ions and used in metrological applications, but these are not treated here.

Proceedings of the International School of Physics "Enrico Fermi"•Jan 1, 2001•0 citations

Microchip‐Based Trapped‐Atom Clocks

Vladan Vuletić, Ian D. Leroux, Monika Schleier-Smith

In the absence of other fields, particles fall under gravity, which sets a practical limit on the single-measurement time T. Atomic fountains, where an ensemble of atoms is launched upwards into a ballistic flight region, allow one to increase the measurement time. Since the fractional accuracy of an atomic clock improves with increasing transition frequency, it is natural to consider the use of optical-frequency electronic transitions rather than microwave-frequency hyperfine transitions as the basis for a clock. Clocks operating on optical transitions have already surpassed the much more mature hyperfine-transition atomic-fountain clocks in accuracy, and further improvements are expected. In practice, however, the allowable atom number is severely limited by the onset of collision shifts which, as seen, are the bane of compact trapped-atom clocks. Spin squeezing of superpositions of clock states is an active research area, with several recently demonstrated implementations. Controlled Vocabulary Terms atomic clocks; optical squeezing

Wiley eBooks•Feb 9, 2011•3 citations

Quantum Motion Effects in Atom Interferometry

Dirk Seidel, Juan Gonzalo Muga

Abstract We study the Ramsey interference pattern of ultracold atoms crossing two electromagnetic fields, taking into account quantum motion effects. It is shown that quantum reflection and transmission at the fields lead to a modification of the standard fringes. The implications on present frequency standards are discussed. For weak coupling, the difference between the exact quantum result and the semiclassical result is small but results in a central peak shift that may become important for future accuracies of atomic clocks. In the strong coupling regime, a resonance structure with respect to the detuning is observed and the Ramsey setup acts as a matter‐wave Fabry‐Perot device. Our results question the advantage of using increasingly lower velocities in frequency standards because the peak shift and the resonance positions depend sensitively on very minor variations of the atomic velocity and are difficult to control.

Israel Journal of Chemistry•Dec 1, 2007•1 citation

Scattering of cold atom coherences by hot atoms: Background gas collision shifts of primary fountain clocks

Kurt Gibble

We theoretically analyze frequency shifts of cold-atom clocks due to background gas collisions. Because nearly all collisions with room-temperature background gases that transfer momentum eject cold atoms from a clock, the frequency shifts for cold atoms are significantly different than those of room-temperature clocks. From general arguments, measurements of the loss of Ramsey fringe amplitude can usefully bound this source of systematic error.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•2 citations

Quantum Variational Optimization of Ramsey Interferometry and Atomic Clocks

Raphael Kaubruegger, Denis V. Vasilyev, Marius Schulte +2 more

We discuss quantum variational optimization of Ramsey interferometry with ensembles of N entangled atoms, and its application to atomic clocks based on a Bayesian approach to phase estimation.We identify best input states and generalized measurements within a variational approximation for the corresponding entangling and decoding quantum circuits.These circuits are built from basic quantum operations available for the particular sensor platform, such as one-axis twisting, or finite range interactions.Optimization is defined relative to a cost function, which in the present study is the Bayesian mean squared error of the estimated phase for a given prior distribution; i.e., we optimize for a finite dynamic range of the interferometer.In analogous variational optimizations of optical atomic clocks, we use the Allan deviation for a given Ramsey interrogation time as the relevant cost function for the long-term instability.Remarkably, even low-depth quantum circuits yield excellent results that closely approach the fundamental quantum limits for optimal Ramsey interferometry and atomic clocks.The quantum metrological schemes identified here are readily applicable to atomic clocks based on optical lattices, tweezer arrays, or trapped ions.While in the present work variationally optimized circuits are found with classical simulations, optimization can also be performed "on" the (physical) quantum sensor, also in regimes not accessible to classical computations and in the presence of imperfections.

arXiv:2102.05593•Physical Review X•Dec 6, 2021•105 citations

Time-Energy Uncertainty Relation for Noisy Quantum Metrology

Philippe Faist, Mischa P. Woods, Victor V. Albert +3 more

The impact of noise on the accuracy of a quantum clock is investigated, unveiling a necessary and sufficient requirement for accuracy that extends standard error-correcting conditions to quantum metrology.

arXiv:2207.13707•PRX Quantum•Dec 5, 2023•14 citations
Fundamental low-energy limits to the accuracy of quantum clock and stopwatch models in which the clock hand motion is activated by the presence of a particle in a region of space have been studied in the past, but their relevance for actual atomic clocks had not been assessed. In this work we address the effect of slow atomic quantum motion on Rabi and Ramsey resonance fringe patterns, as a perturbation of the results based on classical atomic motion. We find the dependence of the fractional error of the corresponding atomic clocks on the atomic velocity and interaction parameters.
The thermal motion of atoms often imposes limitations on the precision and accuracy of measurements involving those atoms. Atomic beam cesium clocks are one outstanding example, where the typical thermal velocity of the cesium atoms, on the order of 200 m/s, limits the observation time to a few milliseconds in a typical apparatus. This finite observation time results in a linewidth for the microwave resonance whose frequency defines the unit of time. Other motional effects include first- and second-order Doppler effects whose presence limits the performance of such clocks. Because conventional refrigeration would result in the condensation of cesium or other atoms into a solid, researchers sought other means of reducing the thermal motion, a quest that led to laser cooling and electromagnetic manipulation of neutral atoms. Similar techniques have been developed for trapped ions and used in metrological applications, but these are not treated here.
In the absence of other fields, particles fall under gravity, which sets a practical limit on the single-measurement time T. Atomic fountains, where an ensemble of atoms is launched upwards into a ballistic flight region, allow one to increase the measurement time. Since the fractional accuracy of an atomic clock improves with increasing transition frequency, it is natural to consider the use of optical-frequency electronic transitions rather than microwave-frequency hyperfine transitions as the basis for a clock. Clocks operating on optical transitions have already surpassed the much more mature hyperfine-transition atomic-fountain clocks in accuracy, and further improvements are expected. In practice, however, the allowable atom number is severely limited by the onset of collision shifts which, as seen, are the bane of compact trapped-atom clocks. Spin squeezing of superpositions of clock states is an active research area, with several recently demonstrated implementations. Controlled Vocabulary Terms atomic clocks; optical squeezing
Abstract We study the Ramsey interference pattern of ultracold atoms crossing two electromagnetic fields, taking into account quantum motion effects. It is shown that quantum reflection and transmission at the fields lead to a modification of the standard fringes. The implications on present frequency standards are discussed. For weak coupling, the difference between the exact quantum result and the semiclassical result is small but results in a central peak shift that may become important for future accuracies of atomic clocks. In the strong coupling regime, a resonance structure with respect to the detuning is observed and the Ramsey setup acts as a matter‐wave Fabry‐Perot device. Our results question the advantage of using increasingly lower velocities in frequency standards because the peak shift and the resonance positions depend sensitively on very minor variations of the atomic velocity and are difficult to control.
We discuss quantum variational optimization of Ramsey interferometry with ensembles of N entangled atoms, and its application to atomic clocks based on a Bayesian approach to phase estimation.We identify best input states and generalized measurements within a variational approximation for the corresponding entangling and decoding quantum circuits.These circuits are built from basic quantum operations available for the particular sensor platform, such as one-axis twisting, or finite range interactions.Optimization is defined relative to a cost function, which in the present study is the Bayesian mean squared error of the estimated phase for a given prior distribution; i.e., we optimize for a finite dynamic range of the interferometer.In analogous variational optimizations of optical atomic clocks, we use the Allan deviation for a given Ramsey interrogation time as the relevant cost function for the long-term instability.Remarkably, even low-depth quantum circuits yield excellent results that closely approach the fundamental quantum limits for optimal Ramsey interferometry and atomic clocks.The quantum metrological schemes identified here are readily applicable to atomic clocks based on optical lattices, tweezer arrays, or trapped ions.While in the present work variationally optimized circuits are found with classical simulations, optimization can also be performed "on" the (physical) quantum sensor, also in regimes not accessible to classical computations and in the presence of imperfections.