Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0810.2221 · Physical Review A

Cancellation of nonlinear Zeeman shifts with light shifts

Kasper Jensen, Víctor M. Acosta, James Higbie, M. P. Ledbetter, Simon Rochester, Dmitry Budker

Published Feb 4, 2009• 66 citations
arXivHTMLPDF

Abstract

Nonlinear Zeeman (NLZ) shifts arising from magnetic-field mixing of the two hyperfine ground states in alkali-metal atoms lead to splitting of magnetic-resonance lines. This is a major source of sensitivity degradation and the so-called ``heading errors'' of alkali-metal-vapor atomic magnetometers operating in the geophysical field range $(B\ensuremath{\approx}0.2--0.7\phantom{\rule{0.3em}{0ex}}\mathrm{G})$. Here, it is shown theoretically and experimentally that NLZ shifts can be effectively canceled by light shifts caused by a laser field of appropriate intensity, polarization, and frequency, a technique that can be readily applied in practical situations.

DOI
10.1103/physreva.79.023406

Related papers

Suppression of the Nonlinear Zeeman Effect and Heading Error in Earth-Field-Range Alkali-Vapor Magnetometers

Guzhi Bao, Arne Wickenbrock, Simon Rochester +2 more

The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.

arXiv:1708.05262•Physical Review Letters•Jan 17, 2018•71 citations

All-optical spin locking in alkali-metal-vapor magnetometers

Guzhi Bao, Dimitra Kanta, D. Antypas +5 more

The nonlinear Zeeman effect can induce splittings and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. We demonstrate an all-optical scheme, based on spin locking, to suppress the nonlinear Zeeman effect. This scheme achieves spin locking via an effective oscillating magnetic field in the form of AC Stark shifts induced by an intensity- and polarization-modulated laser beam. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with $\ensuremath{\sim}100\phantom{\rule{0.16em}{0ex}}\mathrm{Hz}$ width in the Earth-field range into a peak with a central component width of 25 Hz. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude and decreasing its width. An advantage of the all-optical approach is the absence of crosstalk between nearby sensors when they are used in a gradiometric or array arrangement.

arXiv:1809.10906•Physical Review A•Apr 11, 2022•14 citations

Heading-Error-Free Optical Atomic Magnetometry in the Earth-Field Range

Rui Zhang, Dimitra Kanta, Arne Wickenbrock +2 more

We demonstrate an alignment-based $^{87}\mathrm{Rb}$ magnetometer that is immune to nonlinear Zeeman (NLZ) splitting, addressing an important problem in alkali-metal atomic magnetometry. In our scheme, there is a single magnetic resonance peak and well-separated hyperfine transition frequencies, making the magnetometer insensitive or even immune to NLZ-related heading errors. It is shown that the magnetometer can be implemented for practical measurements in geomagnetic environments, and the photon-shot-noise-limited sensitivity reaches $9\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ at $5\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ and remains at tens of $\mathrm{fT}/\sqrt{\mathrm{Hz}}$ at $50\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ at room temperature.

arXiv:2204.05071•Physical Review Letters•Apr 12, 2023•34 citations

Reduction of frequency-dependent light shifts in light-narrowing regimes: A study using effective master equations

Yue Chang, Yuhao Guo, Jie Qin

Alkali-metal-vapor magnetometers, using coherent precession of polarized atomic spins for magnetic-field measurement, have become one of the most sensitive magnetic-field detectors. Their application areas range from practical uses such as NMR signal detection to fundamental physics research such as searches for permanent electric dipole moments. One of the main noise sources of atomic magnetometers comes from the light shift that depends on the frequency of the pump laser. In this work, we theoretically study the light shift, taking into account the relaxation due to the optical pumping and the collision between alkali-metal atoms and between alkali-metal atoms and the buffer gas. Starting from a full master equation containing both the ground and excited states, we adiabatically eliminate the excited states and obtain an effective master equation in the ground-state subspace that shows an intuitive picture and dramatically accelerates the numerical simulation. Solving this effective master equation, we find that in the light-narrowing regime, where the linewidth is reduced while the coherent precession signal is enhanced, the frequency dependence of the light shift is largely reduced, which agrees with experimental observations in cesium magnetometers. Since this effective master equation is general and is easily solved, it can be applied to an extensive parameter regime, and also to study other physical problems in alkali-metal-vapor magnetometers, such as heading errors.

arXiv:1811.01445•Physical Review A•Jun 17, 2019•12 citations

Sources of heading errors in optically pumped magnetometers operated in the Earth's magnetic field

G. Oelsner, V. Schultze, R.P.J. IJsselsteijn +2 more

When optically pumped magnetometers are aimed for use in the Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement results. Measurement errors and inaccuracies related to the heading of the sensor can be an even more severe problem in the case of special operational configurations, such as the use of strong off-resonant pumping. We systematically study the main contributions to the heading error in systems that promise high magnetic field resolutions at the Earth's magnetic field strengths, namely the nonlinear Zeeman splitting and the orientation-dependent light shift. The good correspondence of our theoretical analysis to experimental data demonstrates that both of these effects are related to a heading-dependent modification of the interaction between the laser light and the dipole moment of the atoms. Also, our results promise a compensation of both effects using a combination of clockwise and counterclockwise circular polarization.

arXiv:1809.00627•Physical Review A•Jan 16, 2019•52 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•7 citations
Nonlinear Zeeman (NLZ) shifts arising from magnetic-field mixing of the two hyperfine ground states in alkali-metal atoms lead to splitting of magnetic-resonance lines. This is a major source of sensitivity degradation and the so-called ``heading errors'' of alkali-metal-vapor atomic magnetometers operating in the geophysical field range (B\ensuremath≈0.2−−0.7G)(B\ensuremath{\approx}0.2--0.7\phantom{\rule{0.3em}{0ex}}\mathrm{G})(B\ensuremath≈0.2−−0.7G). Here, it is shown theoretically and experimentally that NLZ shifts can be effectively canceled by light shifts caused by a laser field of appropriate intensity, polarization, and frequency, a technique that can be readily applied in practical situations.
The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.
The nonlinear Zeeman effect can induce splittings and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. We demonstrate an all-optical scheme, based on spin locking, to suppress the nonlinear Zeeman effect. This scheme achieves spin locking via an effective oscillating magnetic field in the form of AC Stark shifts induced by an intensity- and polarization-modulated laser beam. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with $\ensuremath{\sim}100\phantom{\rule{0.16em}{0ex}}\mathrm{Hz}$ width in the Earth-field range into a peak with a central component width of 25 Hz. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude and decreasing its width. An advantage of the all-optical approach is the absence of crosstalk between nearby sensors when they are used in a gradiometric or array arrangement.
We demonstrate an alignment-based 87Rb^{87}\mathrm{Rb}87Rb magnetometer that is immune to nonlinear Zeeman (NLZ) splitting, addressing an important problem in alkali-metal atomic magnetometry. In our scheme, there is a single magnetic resonance peak and well-separated hyperfine transition frequencies, making the magnetometer insensitive or even immune to NLZ-related heading errors. It is shown that the magnetometer can be implemented for practical measurements in geomagnetic environments, and the photon-shot-noise-limited sensitivity reaches 9  fT/Hz9\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}9  fT/Hz​ at $5\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ and remains at tens of fT/Hz\mathrm{fT}/\sqrt{\mathrm{Hz}}fT/Hz​ at $50\text{ }\text{ }\mathrm{\ensuremath{\mu}}\mathrm{T}$ at room temperature.
Alkali-metal-vapor magnetometers, using coherent precession of polarized atomic spins for magnetic-field measurement, have become one of the most sensitive magnetic-field detectors. Their application areas range from practical uses such as NMR signal detection to fundamental physics research such as searches for permanent electric dipole moments. One of the main noise sources of atomic magnetometers comes from the light shift that depends on the frequency of the pump laser. In this work, we theoretically study the light shift, taking into account the relaxation due to the optical pumping and the collision between alkali-metal atoms and between alkali-metal atoms and the buffer gas. Starting from a full master equation containing both the ground and excited states, we adiabatically eliminate the excited states and obtain an effective master equation in the ground-state subspace that shows an intuitive picture and dramatically accelerates the numerical simulation. Solving this effective master equation, we find that in the light-narrowing regime, where the linewidth is reduced while the coherent precession signal is enhanced, the frequency dependence of the light shift is largely reduced, which agrees with experimental observations in cesium magnetometers. Since this effective master equation is general and is easily solved, it can be applied to an extensive parameter regime, and also to study other physical problems in alkali-metal-vapor magnetometers, such as heading errors.
When optically pumped magnetometers are aimed for use in the Earth's magnetic field, the orientation of the sensor to the field direction is of special importance to achieve accurate measurement results. Measurement errors and inaccuracies related to the heading of the sensor can be an even more severe problem in the case of special operational configurations, such as the use of strong off-resonant pumping. We systematically study the main contributions to the heading error in systems that promise high magnetic field resolutions at the Earth's magnetic field strengths, namely the nonlinear Zeeman splitting and the orientation-dependent light shift. The good correspondence of our theoretical analysis to experimental data demonstrates that both of these effects are related to a heading-dependent modification of the interaction between the laser light and the dipole moment of the atoms. Also, our results promise a compensation of both effects using a combination of clockwise and counterclockwise circular polarization.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.