Time-Resolved Detection of Single-Electron Interference

Simon Gustavsson, Renaud Leturcq, M. Studer, Thomas Ihn, K. Ensslin, Daniel C. Driscoll, Arthur C. Gossard

Published Jul 9, 2008• 58 citations
arXivHTMLPDF

Abstract

We demonstrate real-time detection of self-interfering electrons in a double quantum dot embedded in an Aharonov-Bohm interferometer, with visibility approaching unity. We use a quantum point contact as a charge detector to perform time-resolved measurements of single-electron tunneling. With increased bias voltage, the quantum point contact exerts a back-action on the interferometer leading to decoherence. We attribute this to emission of radiation from the quantum point contact, which drives noncoherent electronic transitions in the quantum dots.

DOI
10.1021/nl801689t

Related papers

Charge detection in a closed-loop Aharonov-Bohm interferometer

Gyong Luck Khym, Kicheon Kang

We report on a study of complementarity in a two-terminal closed-loop Aharonov-Bohm interferometer. In this interferometer, the simple picture of two-path interference cannot be applied. We introduce a nearby quantum point contact to detect the electron in a quantum dot inserted in the interferometer. We found that charge detection reduces but does not completely suppress the interference even in the limit of perfect detection. We attribute this phenomenon to the unique nature of the closed-loop interferometer. That is, the closed-loop interferometer cannot be simply regarded as a two-path interferometer because of multiple reflections of electrons. As a result, there exist indistinguishable paths of the electron in the interferometer and the interference survives even in the limit of perfect charge detection. This implies that charge detection is not equivalent to path detection in a closed-loop interferometer. We also discuss the phase rigidity of the transmission probability for a two-terminal conductor in the presence of a detector.

arXiv:quant-ph/0606117•Physical Review B•Oct 20, 2006•17 citations

Time-resolved charge detection with cross-correlation techniques

Bruno Küng, Oliver Pfäffli, Simon Gustavsson +4 more

We present time-resolved charge-sensing measurements on a GaAs double quantum dot with two proximal quantum point-contact (QPC) detectors. The QPC currents are analyzed with cross-correlation techniques, which enable us to measure dot charging and discharging rates for significantly smaller signal-to-noise ratios than required for charge detection with a single QPC. This allows us to reduce the current level in the detector and therefore the invasiveness of the detection process and may help to increase the available measurement bandwidth in noise-limited setups.

arXiv:0810.2406•Physical Review B•Jan 13, 2009•17 citations

Real-Time Observation of Charge States and Energy Relaxation in a Double Quantum Dot

T. Hayashi, T. Fujisawa, Ritsuya Tomita +1 more

We performed real-time observation of charge states in a double quantum dot (QD) by monitoring the current passing through an adjacent quantum point contact (QPC). The position of the QPC was chosen in such a way that the Coulomb coupling of the QPC to one QD is made stronger than to the other QD, so that the QPC current can clearly resolve the charge states of the double QD. With a response time of ∼200 µs, we also investigated the energy relaxation time T 1 of the double QD by applying rectangular voltage pulses to the double QD. We confirmed that T 1 can be made sufficiently longer than the response time of the QPC.

Japanese Journal of Applied Physics•Apr 1, 2006•2 citations

Frequency-Selective Single-Photon Detection Using a Double Quantum Dot

Simon Gustavsson, M. Studer, Renaud Leturcq +4 more

We use a double quantum dot as a frequency-tunable on-chip microwave detector to investigate the radiation from electron shot-noise in a near-by quantum point contact. The device is realized by monitoring the inelastic tunneling of electrons between the quantum dots due to photon absorption. The frequency of the absorbed radiation is set by the energy separation between the dots, which is easily tuned with gate voltages. Using time-resolved charge-detection techniques, we can directly relate the detection of a tunneling electron to the absorption of a single photon.

arXiv:0705.3166•Physical Review Letters•Nov 14, 2007•168 citations

Quantum Coherence in a One-Electron Semiconductor Charge Qubit

Karl D. Petersson, J. R. Petta, Hong Lü +1 more

We study quantum coherence in a semiconductor charge qubit formed from a GaAs double quantum dot containing a single electron. Voltage pulses are applied to depletion gates to drive qubit rotations and noninvasive state readout is achieved using a quantum point contact charge detector. We measure a maximum coherence time of ∼7 ns at the charge degeneracy point, where the qubit level splitting is first-order insensitive to gate voltage fluctuations. We compare measurements of the coherence time as a function of detuning with numerical simulations and predictions from a 1/f noise model.

arXiv:1008.3089•Physical Review Letters•Dec 8, 2010•390 citations

Telegraph Noise in Coupled Quantum Dot Circuits Induced by a Quantum Point Contact

D. Taubert, Michel Pioro-Ladrière, D. Schröer +3 more

Charge detection utilizing a highly biased quantum point contact has become the most effective probe for studying few electron quantum dot circuits. Measurements on double and triple quantum dot circuits is performed to clarify a back action role of charge sensing on the confined electrons. The quantum point contact triggers inelastic transitions, which occur quite generally. Under specific device and measurement conditions these transitions manifest themselves as bounded regimes of telegraph noise within a stability diagram. A nonequilibrium transition from artificial atomic to molecular behavior is identified. Consequences for quantum information applications are discussed.

arXiv:0801.4002•Physical Review Letters•May 2, 2008•45 citations
We demonstrate real-time detection of self-interfering electrons in a double quantum dot embedded in an Aharonov-Bohm interferometer, with visibility approaching unity. We use a quantum point contact as a charge detector to perform time-resolved measurements of single-electron tunneling. With increased bias voltage, the quantum point contact exerts a back-action on the interferometer leading to decoherence. We attribute this to emission of radiation from the quantum point contact, which drives noncoherent electronic transitions in the quantum dots.
We report on a study of complementarity in a two-terminal closed-loop Aharonov-Bohm interferometer. In this interferometer, the simple picture of two-path interference cannot be applied. We introduce a nearby quantum point contact to detect the electron in a quantum dot inserted in the interferometer. We found that charge detection reduces but does not completely suppress the interference even in the limit of perfect detection. We attribute this phenomenon to the unique nature of the closed-loop interferometer. That is, the closed-loop interferometer cannot be simply regarded as a two-path interferometer because of multiple reflections of electrons. As a result, there exist indistinguishable paths of the electron in the interferometer and the interference survives even in the limit of perfect charge detection. This implies that charge detection is not equivalent to path detection in a closed-loop interferometer. We also discuss the phase rigidity of the transmission probability for a two-terminal conductor in the presence of a detector.
We present time-resolved charge-sensing measurements on a GaAs double quantum dot with two proximal quantum point-contact (QPC) detectors. The QPC currents are analyzed with cross-correlation techniques, which enable us to measure dot charging and discharging rates for significantly smaller signal-to-noise ratios than required for charge detection with a single QPC. This allows us to reduce the current level in the detector and therefore the invasiveness of the detection process and may help to increase the available measurement bandwidth in noise-limited setups.
We performed real-time observation of charge states in a double quantum dot (QD) by monitoring the current passing through an adjacent quantum point contact (QPC). The position of the QPC was chosen in such a way that the Coulomb coupling of the QPC to one QD is made stronger than to the other QD, so that the QPC current can clearly resolve the charge states of the double QD. With a response time of ∼200 µs, we also investigated the energy relaxation time T 1 of the double QD by applying rectangular voltage pulses to the double QD. We confirmed that T 1 can be made sufficiently longer than the response time of the QPC.
We use a double quantum dot as a frequency-tunable on-chip microwave detector to investigate the radiation from electron shot-noise in a near-by quantum point contact. The device is realized by monitoring the inelastic tunneling of electrons between the quantum dots due to photon absorption. The frequency of the absorbed radiation is set by the energy separation between the dots, which is easily tuned with gate voltages. Using time-resolved charge-detection techniques, we can directly relate the detection of a tunneling electron to the absorption of a single photon.
We study quantum coherence in a semiconductor charge qubit formed from a GaAs double quantum dot containing a single electron. Voltage pulses are applied to depletion gates to drive qubit rotations and noninvasive state readout is achieved using a quantum point contact charge detector. We measure a maximum coherence time of ∼7 ns at the charge degeneracy point, where the qubit level splitting is first-order insensitive to gate voltage fluctuations. We compare measurements of the coherence time as a function of detuning with numerical simulations and predictions from a 1/f noise model.
Charge detection utilizing a highly biased quantum point contact has become the most effective probe for studying few electron quantum dot circuits. Measurements on double and triple quantum dot circuits is performed to clarify a back action role of charge sensing on the confined electrons. The quantum point contact triggers inelastic transitions, which occur quite generally. Under specific device and measurement conditions these transitions manifest themselves as bounded regimes of telegraph noise within a stability diagram. A nonequilibrium transition from artificial atomic to molecular behavior is identified. Consequences for quantum information applications are discussed.