arXiv:0807.1446 · Optics Letters

Electronic noise-free measurements of squeezed light

Leonid A. Krivitsky, Ulrik L. Andersen, Ruifang Dong, Alexander Huck, Christoffer Wittmann, Gerd Leuchs

Published Oct 14, 2008• 7 citations
arXivHTMLPDF

Abstract

We study the implementation of a correlation measurement technique for the characterization of squeezed light. We show that the sign of the covariance coefficient revealed from the time-resolved correlation data allow us to distinguish among squeezed, coherent, and thermal states. In contrast to the traditional method of characterizing squeezed light, involving measurement of the variation of the difference photocurrent, the correlation measurement method allows one to eliminate the contribution of the electronic noise, which becomes a crucial issue in experiments with dim sources of squeezed light.

DOI
10.1364/ol.33.002395

Related papers

Correlation measurement of squeezed light

Leonid A. Krivitsky, Ulrik L. Andersen, Ruifang Dong +3 more

We study the implementation of a correlation measurement technique for the characterization of squeezed light which is nearly free of electronic noise. With two different sources of squeezed light, we show that the sign of the covariance coefficient, revealed from the time-resolved correlation data, is witnessing the presence of squeezing in the system. Furthermore, we estimate the degree of squeezing using the correlation method and compare it to the standard homodyne measurement scheme. We show that the role of electronic detector noise is minimized using the correlation approach as opposed to homodyning where it often becomes a crucial issue.

arXiv:0903.3999•Physical Review A•Mar 18, 2009•6 citations

Correlation spectroscopy with squeezed light

V. V. Batygin, Dmitriy V. Kupriyanov, Igor M. Sokolov

We have discussed the possibilities of correlation spectroscopy (light beating spectroscopy) technique if squeezed light is used as a probe radiation for medium monitoring. The dispersion of the fluctuation of photocurrent spectrum measured in this method is expressed in terms of fourth order photocurrent correlation function. This correlation function is considered and evaluated in assumptions of photodetection theory developed by Glauber in first nonvanishing orders in interaction of probe light with the atoms of a photodetector. We show that fourth order correlation function is determined by all field TN-ordered amplitude correlation functions up to the fourth order. In case of heterodyne detection, when the light incident on photodetector surface is the mix of strong coherent modes of local oscillator wave and weak non-coherent (squeezed) modes, the observable (photocurrent spectrum) as well as its fluctuation (noise of photocurrent spectrum) is expressed in terms of spectrum-dependent Mandel parameter. We have discussed possible improvement of sensitivity limit for correlation spectroscopy in this case.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 6, 1996•0 citations

SENSING BY SQUEEZED STATES OF LIGHT

Virginia D’Auria, A. Porzio, Salvatore Solimeno

Squeezed states of light represent the most famous type of non-classical radiation states. They are characterized by a reduction of the quantum noise in one of the field observables, with respect to the noise affecting a coherent beam of the same amplitude (the standard quantum limit). This peculiarity in the noise property has suggested the use of these states in particular measurement schemes to beat the limit imposed by standard quantum noise. This contribution aims to briefly review three applications of squeezed states: (i) quantum interferometry; (ii) absorption measurements; (iii) high resolution imaging.

Series in optics and photonics•Jan 1, 2009•0 citations

Squeezed states of light

Harry J. Kimble

Squeezed states of the electromagnetic field are characterized by a reduction of fluctuations for one of two quadrature phase amplitudes below the level of fluctuations for the vacuum state. This reduction is a manifestly quantum or nonclassical feature which is of great interest in its own right but also potentially important for precision measurement with sensitivity beyond the shot-noise or vacuum-state limit. We describe three different experiments in which squeezed light has been generated in our laboratory involving parametric downconversion, intracavity frequency doubling, and optical bistability with two-state atoms. By employing the squeezed light produced by a subthreshold optical parametric oscillator, we have achieved improvements in sensitivity beyond the vacuum-state limit for the detection of both phase and amplitude changes of the electromagnetic field. An alternate route to sensitivity beyond the vacuum-state limit is through quantum nondemolition measurement, where we have suggested and are implementing a scheme involving parametric conversion and polarization mixing.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Pulsed squeezed light: characterization and applications

Triginer Garcés, Gil

Squeezed light is expected to enable new quantum metrology and quantum computation applications, but the very high degree of experimental control required in practice places severe demands on the physical devices used to generate it. As ultrafast squeezed light sources are reaching an unprecedented degree of brightness and modal control, there is a strong interest in developing methods for their experimental characterization and theoretical understanding. In this thesis, we demonstrate both a new application and a new characterization technique for pulsed squeezed light. In the first part of the thesis, we present a new metrological application of pulsed squeezed light: quantum-enhanced label-free nonlinear microscopy. Stimulated emission microscopy (SEM) is a state-of-the-art pump-probe microscopy technique whose sensitivity is ultimately limited by shot noise in the probe beam. We propose to overcome this fundamental limitation by using a sub-Poissonian probe generated via optical parametric amplification. We demonstrate an intensity-squeezed sub-picosecond pulsed probe, and a simple stimulated emission microscope. Using this squeezed probe, sub-Poissonian statistics are observed in the SEM signal. After this proof-of-principle experiment, we aim to provide an improved design for a source of intensity-squeezed light. First, we develop a theoretical framework to simulate the photon statistics of a general sub-Poissonian source, considering pulsed and focused pump and seed fields in a unified spatio-temporal description. Next, we use this framework to suggest possible improvements to our previous squeezed probe. In the second part of this thesis, we provide new theoretical and experimental tools to analyze the high gain regime of pulsed spontaneous parametric down-conversion (SPDC). We study a waveguided source capable of generating twin-beams with tens of photons in a single spatio-temporal mode. We develop a framework to efficiently simulate SPDC for an arbitrary nonlinear gain, including the effect of parasitic nonlinearities such as self-phase modulation (SPM) of the pump and cross-phase modulation (XPM) between pump and twin-beams. We experimentally characterize our source using a new technique based on stimulated difference-frequency generation (DFG). In a type-II down-conversion process, we measure the frequency generation produced not only in the orthogonal polarization to the seeding beam, but also in its same polarization, which we interpret as cascaded difference-frequency generation. We argue that the additional information obtained in this measurement allows for a self-referenced estimation of the squeezing gain. Using these measurements, we accurately fit our theoretical model, revealing that, in the high gain regime, parasitic nonlinearities strongly affect the spectral structure of the twin-beams. We propose a simple strategy to reduce the impact of these nonlinearities on the modal structure of SPDC.

•Jan 1, 2019•0 citations

Intensity feedback effects on quantum-limited noise

Matthew S. Taubman, Howard M. Wiseman, David E. McClelland +1 more

We examine the quantum-limited behavior of an electro-optical intensity feedback loop and present a simple theory and experimental data showing excellent agreement. We show that, although the light incident upon the in-loop detector may be sub-Poissonian, this light has unique properties different from those of a freely propagating beam of intensity squeezed light. We support this by presenting the results of homodyne measurements of the phase noise of light extracted from the loop. The utility of the in-loop field is discussed, and it is shown that in all cases in which linear optical components are used, no advantage in signal-to-noise ratio is gained by taking measurements by using this light rather than a coherent source. We also discuss effects seen in the extracted or out-of-loop light. We demonstrate the existence of, and derive an expression for, an optimum gain for suppressing low-level classical noise. Conversely, in the high-gain limit, we demonstrate that the extra noise seen in the out-of-loop photocurrent that is due to the feedback process is expressible purely in terms of the mean photocurrents involved. Lastly, we introduce the novel concept of using an intensity feedback loop in conjunction with a squeezed source and show that the feedback loop has the capability of electronically transferring squeezing from one light beam to another.

Journal of the Optical Society of America B•Oct 1, 1995•53 citations
We study the implementation of a correlation measurement technique for the characterization of squeezed light. We show that the sign of the covariance coefficient revealed from the time-resolved correlation data allow us to distinguish among squeezed, coherent, and thermal states. In contrast to the traditional method of characterizing squeezed light, involving measurement of the variation of the difference photocurrent, the correlation measurement method allows one to eliminate the contribution of the electronic noise, which becomes a crucial issue in experiments with dim sources of squeezed light.
We study the implementation of a correlation measurement technique for the characterization of squeezed light which is nearly free of electronic noise. With two different sources of squeezed light, we show that the sign of the covariance coefficient, revealed from the time-resolved correlation data, is witnessing the presence of squeezing in the system. Furthermore, we estimate the degree of squeezing using the correlation method and compare it to the standard homodyne measurement scheme. We show that the role of electronic detector noise is minimized using the correlation approach as opposed to homodyning where it often becomes a crucial issue.
We have discussed the possibilities of correlation spectroscopy (light beating spectroscopy) technique if squeezed light is used as a probe radiation for medium monitoring. The dispersion of the fluctuation of photocurrent spectrum measured in this method is expressed in terms of fourth order photocurrent correlation function. This correlation function is considered and evaluated in assumptions of photodetection theory developed by Glauber in first nonvanishing orders in interaction of probe light with the atoms of a photodetector. We show that fourth order correlation function is determined by all field TN-ordered amplitude correlation functions up to the fourth order. In case of heterodyne detection, when the light incident on photodetector surface is the mix of strong coherent modes of local oscillator wave and weak non-coherent (squeezed) modes, the observable (photocurrent spectrum) as well as its fluctuation (noise of photocurrent spectrum) is expressed in terms of spectrum-dependent Mandel parameter. We have discussed possible improvement of sensitivity limit for correlation spectroscopy in this case.
Squeezed states of light represent the most famous type of non-classical radiation states. They are characterized by a reduction of the quantum noise in one of the field observables, with respect to the noise affecting a coherent beam of the same amplitude (the standard quantum limit). This peculiarity in the noise property has suggested the use of these states in particular measurement schemes to beat the limit imposed by standard quantum noise. This contribution aims to briefly review three applications of squeezed states: (i) quantum interferometry; (ii) absorption measurements; (iii) high resolution imaging.
Squeezed states of the electromagnetic field are characterized by a reduction of fluctuations for one of two quadrature phase amplitudes below the level of fluctuations for the vacuum state. This reduction is a manifestly quantum or nonclassical feature which is of great interest in its own right but also potentially important for precision measurement with sensitivity beyond the shot-noise or vacuum-state limit. We describe three different experiments in which squeezed light has been generated in our laboratory involving parametric downconversion, intracavity frequency doubling, and optical bistability with two-state atoms. By employing the squeezed light produced by a subthreshold optical parametric oscillator, we have achieved improvements in sensitivity beyond the vacuum-state limit for the detection of both phase and amplitude changes of the electromagnetic field. An alternate route to sensitivity beyond the vacuum-state limit is through quantum nondemolition measurement, where we have suggested and are implementing a scheme involving parametric conversion and polarization mixing.
Squeezed light is expected to enable new quantum metrology and quantum computation applications, but the very high degree of experimental control required in practice places severe demands on the physical devices used to generate it. As ultrafast squeezed light sources are reaching an unprecedented degree of brightness and modal control, there is a strong interest in developing methods for their experimental characterization and theoretical understanding. In this thesis, we demonstrate both a new application and a new characterization technique for pulsed squeezed light. In the first part of the thesis, we present a new metrological application of pulsed squeezed light: quantum-enhanced label-free nonlinear microscopy. Stimulated emission microscopy (SEM) is a state-of-the-art pump-probe microscopy technique whose sensitivity is ultimately limited by shot noise in the probe beam. We propose to overcome this fundamental limitation by using a sub-Poissonian probe generated via optical parametric amplification. We demonstrate an intensity-squeezed sub-picosecond pulsed probe, and a simple stimulated emission microscope. Using this squeezed probe, sub-Poissonian statistics are observed in the SEM signal. After this proof-of-principle experiment, we aim to provide an improved design for a source of intensity-squeezed light. First, we develop a theoretical framework to simulate the photon statistics of a general sub-Poissonian source, considering pulsed and focused pump and seed fields in a unified spatio-temporal description. Next, we use this framework to suggest possible improvements to our previous squeezed probe. In the second part of this thesis, we provide new theoretical and experimental tools to analyze the high gain regime of pulsed spontaneous parametric down-conversion (SPDC). We study a waveguided source capable of generating twin-beams with tens of photons in a single spatio-temporal mode. We develop a framework to efficiently simulate SPDC for an arbitrary nonlinear gain, including the effect of parasitic nonlinearities such as self-phase modulation (SPM) of the pump and cross-phase modulation (XPM) between pump and twin-beams. We experimentally characterize our source using a new technique based on stimulated difference-frequency generation (DFG). In a type-II down-conversion process, we measure the frequency generation produced not only in the orthogonal polarization to the seeding beam, but also in its same polarization, which we interpret as cascaded difference-frequency generation. We argue that the additional information obtained in this measurement allows for a self-referenced estimation of the squeezing gain. Using these measurements, we accurately fit our theoretical model, revealing that, in the high gain regime, parasitic nonlinearities strongly affect the spectral structure of the twin-beams. We propose a simple strategy to reduce the impact of these nonlinearities on the modal structure of SPDC.
We examine the quantum-limited behavior of an electro-optical intensity feedback loop and present a simple theory and experimental data showing excellent agreement. We show that, although the light incident upon the in-loop detector may be sub-Poissonian, this light has unique properties different from those of a freely propagating beam of intensity squeezed light. We support this by presenting the results of homodyne measurements of the phase noise of light extracted from the loop. The utility of the in-loop field is discussed, and it is shown that in all cases in which linear optical components are used, no advantage in signal-to-noise ratio is gained by taking measurements by using this light rather than a coherent source. We also discuss effects seen in the extracted or out-of-loop light. We demonstrate the existence of, and derive an expression for, an optimum gain for suppressing low-level classical noise. Conversely, in the high-gain limit, we demonstrate that the extra noise seen in the out-of-loop photocurrent that is due to the feedback process is expressible purely in terms of the mean photocurrents involved. Lastly, we introduce the novel concept of using an intensity feedback loop in conjunction with a squeezed source and show that the feedback loop has the capability of electronically transferring squeezing from one light beam to another.