Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:0708.0301 · Physical Review A

Fast recognition of single molecules based on single-event photon statistics

Shuangli Dong, Tao Huang, Yuan Liu, Jun Wang, Guo‐Feng Zhang, Liantuan Xiao, Suotang Jia

Published Dec 27, 2007• 13 citations
arXivHTMLPDF

Abstract

Mandel's $Q$ parameter, which is determined from single-event photon statistics, provides an alternative way to recognize single molecules with fluorescence detection, other than the second-order correlation function. It is shown that the $Q$ parameter of an assumed ideal double-molecule fluorescence with the same average photon number as that of the sample fluorescence can act as the criterion for single-molecule recognition. The influence of signal-to-background ratio and the error estimates for photon statistics are also presented. We have applied this method to ascertain single Cy5 dye molecules within hundreds of milliseconds.

DOI
10.1103/physreva.76.063820

Related papers

Identifying single molecule based on the photon statistics

Peng Shuang-Yan, Huang Tao, Xiaobo Wang +4 more

We theoretically study the photon counting statistics characterizations of the real single molecular photon source with a Poisson statistics background and that of an ideal double molecular system based on the standard HBT detection. Mandel parameter Q of each source with the same mean photons n—was analyzed. We have obtained an efficient method to identify single molecule by the two-photon statistics probability P(2), which shows the relation P(2)2. Additionally, we studied the effect of single-to-background ratio of the single molecular photon source on the criterion.

Acta Physica Sinica•Jan 1, 2005•0 citations

Effect of Background Noise on the Photon Statistics of Triggered Single Molecules

Liantuan Xiao, Yanting Zhao, Huang Tao +3 more

We theoretically derive exact expressions for Mandel's Q parameter of the triggered single molecular source, which is inferred from the probabilities P RS ( n ) using the record of each photon detection event based on Hanbury Brown and Twiss detection. The real triggered source is recognized as an ideal single photon source with a Poissonian statistics background. How to decrease the background and to increase the efficiency are discussed. It is established that the sub-Poissonian statistics formation can be determined by comparing the measured Q RS of the real single triggered molecular with Q C of the Poissonian source containing the same mean photons. By this method, we also give an efficient way to measure signal-to-background ratios of triggered single photons.

Chinese Physics Letters•Feb 19, 2004•7 citations

Optics detection of single molecules

Jia Suo

The principle of single photon source based on three-levels single molecule is introduced. By use of Hanbury-Brown-Twiss method, the photon statistics P(n, n=0、1、2) and the Mandel parameter are analyzed by recording of every photo-electrical event from the single photon source. When signal to background ratio SBR2.4, an efficient method to distinguish single molecules by the double-photon statistics probability P(2), which shows P(2)12(2-4-2n-)~2, is presented. Here, n- is the mean photon number.

•Jan 1, 2006•0 citations

Photon Statistics of Optical Source from Single Molecule in Room Temperature

Jia Suo-Tang

The principle of optical detection for three-levels single molecule in room temperature were introduced.By use of Hanbury-Brown-Twiss method,the photon statistics P(n,n=0,1,2) and the Mandel parameter were analyzed by recording of every photo-electrical event from the single photon source.In the work,novel and fast approaches for identifying single molecules and the determination of signal to background ratio were presented based on single event photon statistics.

Journal of Shanxi University•Jan 1, 2007•0 citations

Theory for Wavelength-Resolved Photon Emission Statistics in Single-Molecule Fluorescence Spectroscopy

Golan Bel, Frank L. H. Brown

We derive the moment generating function for photon emissions from a single molecule driven by laser excitation. The frequencies of the fluoresced photons are explicitly considered. Calculations are performed for the case of a two-level dye molecule, showing that measured photon statistics will display a strong and nonintuitive dependence on detector bandwidth. Moreover, it is demonstrated that the antibunching phenomenon, associated with negative values of Mandel's Q parameter, results from correlations between photons with well separated frequencies.

arXiv:0908.1924•Physical Review Letters•Jan 9, 2009•47 citations

Determination of signal-to-background ratio of single molecular photon source based on photon counting statistics

Xiao-Bo Wang, Huang Tao, Shao Jun-Hu +4 more

The real triggered single molecule source is recognized as an ideal single photon source with a Poissonian statistics background. By considering the effect of the triplet state in single molecule energy level, an explicit function is given for the signaltobackgound ratio(SBR) by use of photoncounting statistics. When PRS(1)2PRS(2)-3PRS(2), we present an effici ent method to determine the SBR of the triggered single photons source, which s hows SBR=P2RS(1)/2PRS(2).In addition, the expression of Q, as a function of signaltobackgound ratio, has been obtained. It turns o ut that this method is simpler and gives a greater accuracy than previous proce dures.

Acta Physica Sinica•Jan 1, 2005•0 citations
Mandel's QQQ parameter, which is determined from single-event photon statistics, provides an alternative way to recognize single molecules with fluorescence detection, other than the second-order correlation function. It is shown that the QQQ parameter of an assumed ideal double-molecule fluorescence with the same average photon number as that of the sample fluorescence can act as the criterion for single-molecule recognition. The influence of signal-to-background ratio and the error estimates for photon statistics are also presented. We have applied this method to ascertain single Cy5 dye molecules within hundreds of milliseconds.
We theoretically study the photon counting statistics characterizations of the real single molecular photon source with a Poisson statistics background and that of an ideal double molecular system based on the standard HBT detection. Mandel parameter Q of each source with the same mean photons n—was analyzed. We have obtained an efficient method to identify single molecule by the two-photon statistics probability P(2), which shows the relation P(2)2. Additionally, we studied the effect of single-to-background ratio of the single molecular photon source on the criterion.
We theoretically derive exact expressions for Mandel's Q parameter of the triggered single molecular source, which is inferred from the probabilities P RS ( n ) using the record of each photon detection event based on Hanbury Brown and Twiss detection. The real triggered source is recognized as an ideal single photon source with a Poissonian statistics background. How to decrease the background and to increase the efficiency are discussed. It is established that the sub-Poissonian statistics formation can be determined by comparing the measured Q RS of the real single triggered molecular with Q C of the Poissonian source containing the same mean photons. By this method, we also give an efficient way to measure signal-to-background ratios of triggered single photons.
The principle of single photon source based on three-levels single molecule is introduced. By use of Hanbury-Brown-Twiss method, the photon statistics P(n, n=0、1、2) and the Mandel parameter are analyzed by recording of every photo-electrical event from the single photon source. When signal to background ratio SBR2.4, an efficient method to distinguish single molecules by the double-photon statistics probability P(2), which shows P(2)12(2-4-2n-)~2, is presented. Here, n- is the mean photon number.
We derive the moment generating function for photon emissions from a single molecule driven by laser excitation. The frequencies of the fluoresced photons are explicitly considered. Calculations are performed for the case of a two-level dye molecule, showing that measured photon statistics will display a strong and nonintuitive dependence on detector bandwidth. Moreover, it is demonstrated that the antibunching phenomenon, associated with negative values of Mandel's Q parameter, results from correlations between photons with well separated frequencies.
The real triggered single molecule source is recognized as an ideal single photon source with a Poissonian statistics background. By considering the effect of the triplet state in single molecule energy level, an explicit function is given for the signaltobackgound ratio(SBR) by use of photoncounting statistics. When PRS(1)2PRS(2)-3PRS(2), we present an effici ent method to determine the SBR of the triggered single photons source, which s hows SBR=P2RS(1)/2PRS(2).In addition, the expression of Q, as a function of signaltobackgound ratio, has been obtained. It turns o ut that this method is simpler and gives a greater accuracy than previous proce dures.