arXiv:0705.4003 · New Journal of Physics

Photon number projection using non-number-resolving detectors

Peter P. Rohde, James Webb, Elanor H. Huntington, Timothy C. Ralph

Published Jul 17, 2007• 21 citations
arXivHTMLPDF

Abstract

Number-resolving photo-detection is necessary for many quantum optics experiments, especially in the application of entangled state preparation. Several schemes have been proposed for approximating number-resolving photo-detection using non-number-resolving detectors. Such techniques include multi-port detection and time-division multiplexing. We provide a detailed analysis and comparison of different number-resolving detection schemes, with a view to creating a useful reference for experimentalists. We show that the ideal architecture for projective measurements is a function of the detector's dark count and efficiency parameters. We also describe a process for selecting an appropriate topology given actual experimental component parameters.

DOI
10.1088/1367-2630/9/7/233

Related papers

Optimising number resolving photo-detectors using classical post-processing

Peter P. Rohde

Many present day quantum optics experiments, particularly in optical quantum information processing, rely on number-resolving photo-detection as a basic building block. In this paper we demonstrate that a simple classical optimisation technique can sometimes be employed to post-process the detector signature and improve the confidence of the measurement outcome in the presence of photon-number errors such as loss or dark-counts. While the regime in which this technique is applicable is rather restrictive, and will likely not be very useful for the large-scale quantum information processing applications of the future, the ideas presented might be employed in some present-day experiments where photo-detectors are typically very poor.

arXiv:1107.2747•Jul 14, 2011•0 citations

Improving the fidelity of single photon preparation from conditional down-conversion via asymmetric multiport detection

Peter P. Rohde

We discuss the conditional preparation of single photons via parametric down-conversion. This technique is commonly used as a single photon source in modern quantum optics experiments. A significant problem facing this technique is the inability of present day photo-detectors to resolve photon number. This results in mixing with higher photon number terms. To overcome this several techniques have been proposed, including multi-port detection and time-division multiplexing. These techniques help approximate number resolving detection even when using non-number resolving detectors. In this paper we focus on 2-port detection, the simplest such scheme. We show that by making the 2-port device asymmetric the fidelity of prepared photons can be improved.

arXiv:quant-ph/0703238•Mar 26, 2007•3 citations

Non-deterministic approximation of photon number discriminating detectors using non-discriminating detectors

Peter P. Rohde

We present a scheme for non-deterministically approximating photon number resolving detectors using non-discriminating detectors. The model is simple in construction and employs very few physical resources. Despite its non-determinism, the proposal may nonetheless be suitable for use in some quantum optics experiments in which non-determinism can be tolerated. We analyse the detection scheme in the context of an optical implementation of the controlled-NOT gate, an inherently non-deterministic device. This allows the gate's success probability to be traded away for improved gate fidelity, assuming high efficiency detectors. The scheme is compared to two other proposals, both deterministic, for approximating discriminating detectors using non-discriminating detectors: the cascade and time division multiplexing schemes.

arXiv:quant-ph/0411114•Journal of Optics B Quantum and Semiclassical Optics•Jan 29, 2005•8 citations

Applications of quantum measurement techniques: Counterfactual quantum computation, spin hall effect of light, and atomic-vapor-based photon detectors

Onur Hosten

Our approach to ultra-high-efficiency photon detection develops and extends a recent novel non-solid-state scheme for photo-detection based on atomic vapors. This approach is in principle capable of resolving the number of photons in a pulse, can be extended to non-destructive detection of photons, and most importantly is proposed to operate with single-photon detection efficiencies exceeding 99%, ideally without dark counts. Such a detector would have tremendous implications, e.g., for optical quantum information processing. The feasibility of operation of this approach at the desired level is studied theoretically and several promising physical systems are investigated.

•May 19, 2010•0 citations

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•26 citations

Photon-number-resolving detection using time-multiplexing

Daryl Achilles, Christine Silberhorn, Cezary Śliwa +6 more

Detectors that can resolve photon number are needed in many quantum information technologies. In order to be useful in quantum information processing, such detectors should be simple, easy to use, and be scalable to resolve any number of photons, as the application may require great portability such as in quantum cryptography. Here we describe the construction of a time-multiplexed detector, which uses a pair of standard avalanche photodiodes operated in Geiger mode. The detection technique is analysed theoretically and tested experimentally using a pulsed source of weak coherent light.

arXiv:quant-ph/0310183•Journal of Modern Optics•Jan 1, 2004•181 citations
Number-resolving photo-detection is necessary for many quantum optics experiments, especially in the application of entangled state preparation. Several schemes have been proposed for approximating number-resolving photo-detection using non-number-resolving detectors. Such techniques include multi-port detection and time-division multiplexing. We provide a detailed analysis and comparison of different number-resolving detection schemes, with a view to creating a useful reference for experimentalists. We show that the ideal architecture for projective measurements is a function of the detector's dark count and efficiency parameters. We also describe a process for selecting an appropriate topology given actual experimental component parameters.
Many present day quantum optics experiments, particularly in optical quantum information processing, rely on number-resolving photo-detection as a basic building block. In this paper we demonstrate that a simple classical optimisation technique can sometimes be employed to post-process the detector signature and improve the confidence of the measurement outcome in the presence of photon-number errors such as loss or dark-counts. While the regime in which this technique is applicable is rather restrictive, and will likely not be very useful for the large-scale quantum information processing applications of the future, the ideas presented might be employed in some present-day experiments where photo-detectors are typically very poor.
We discuss the conditional preparation of single photons via parametric down-conversion. This technique is commonly used as a single photon source in modern quantum optics experiments. A significant problem facing this technique is the inability of present day photo-detectors to resolve photon number. This results in mixing with higher photon number terms. To overcome this several techniques have been proposed, including multi-port detection and time-division multiplexing. These techniques help approximate number resolving detection even when using non-number resolving detectors. In this paper we focus on 2-port detection, the simplest such scheme. We show that by making the 2-port device asymmetric the fidelity of prepared photons can be improved.
We present a scheme for non-deterministically approximating photon number resolving detectors using non-discriminating detectors. The model is simple in construction and employs very few physical resources. Despite its non-determinism, the proposal may nonetheless be suitable for use in some quantum optics experiments in which non-determinism can be tolerated. We analyse the detection scheme in the context of an optical implementation of the controlled-NOT gate, an inherently non-deterministic device. This allows the gate's success probability to be traded away for improved gate fidelity, assuming high efficiency detectors. The scheme is compared to two other proposals, both deterministic, for approximating discriminating detectors using non-discriminating detectors: the cascade and time division multiplexing schemes.
Our approach to ultra-high-efficiency photon detection develops and extends a recent novel non-solid-state scheme for photo-detection based on atomic vapors. This approach is in principle capable of resolving the number of photons in a pulse, can be extended to non-destructive detection of photons, and most importantly is proposed to operate with single-photon detection efficiencies exceeding 99%, ideally without dark counts. Such a detector would have tremendous implications, e.g., for optical quantum information processing. The feasibility of operation of this approach at the desired level is studied theoretically and several promising physical systems are investigated.
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
Detectors that can resolve photon number are needed in many quantum information technologies. In order to be useful in quantum information processing, such detectors should be simple, easy to use, and be scalable to resolve any number of photons, as the application may require great portability such as in quantum cryptography. Here we describe the construction of a time-multiplexed detector, which uses a pair of standard avalanche photodiodes operated in Geiger mode. The detection technique is analysed theoretically and tested experimentally using a pulsed source of weak coherent light.